NextSDS Logo
Safety Data Sheet EN

Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g
Product Code
14207

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Asp. Tox. Cat. 1 H304

GHS Pictograms

GHS08 - Serious health hazard

GHS08

Hazard Statements

H304 May be fatal if swallowed and enters airways.

Precautionary Statements

P301+P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P331 Do NOT induce vomiting.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Chemical characterization: Mixtures

Chemical Name CAS Number Concentration Hazardous
Mineral oil 8042-47-5 99.9% Yes
Proprietary organo-antimony compound --- --- No

Additional information None known.

Notes

Dangerous components: 8042-47-5 | Mineral oil, Asp. Tox. 1, H304, 99.9%

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Seek medical treatment.

Symptoms: May be fatal if swallowed and enters airways.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Penetration time of glove material (in minutes) Not determined

Eyes

Safety glasses with side shields / NIOSH (US) or EN 166(EU)

Respiratory

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with multi-purpose combination (US) or type ABEK (EN 14387) as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards such as NIOSH (USA) or CEN (EU).

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Dynamic Viscosity
Not determined.
Appearance
Not determined
Relative Evaporation Rate
---
Flammability
Not determined.
Vapor Pressure
Not determined
Evaporation Rate
Not determined.
Softening Point
---
Decomposition Temperature
Not determined
Melting Point
Not determined
Molecular Weight
---
Colour Intensity
---
Ph
Not determined.
Boiling Point
>338 ℃ (>640 °F)
Crystallisation Point
---
Colour
---
Vapor Density
Not determined.
Bulk Density
---
Solubility
Not miscible or difficult to mix
Auto Ignition Temperature
Product is not selfigniting.
Form
Liquid
Solidification Point
---
Cloud Point
---
Flash Point
111 °C (232 ºF)
Partition Coefficient
Not determined.
Properties Status
---
Odor Threshold
Not determined.
Physical State Data
liquid
Solubility In Fat
---
Solubility In Water
Not miscible or difficult to mix
State Under Standard Conditions
---
Odor
Not determined
Lower Explosive Limit
Not determined
Upper Explosive Limit
Not determined
Metal Corrosion
---
Freezing Point
---
Kinematic Viscosity
Not determined.
Relative Density
Not determined.
Explosive Limits
---
Voc Content
---
Density
ca 0.85 g/cm3 (ca 7.093 lbs/gal)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

Shipping Name
Not applicable
Transport Class
Not applicable
Packing Group
Not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g?

The signal word is danger.

What is the physical form of Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g?

Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g is a liquid appearing as not determined . It has not determined odor.

What is the solubility of Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g?

Not miscible or difficult to mix

What is Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g used for?

SU24 Scientific research and development

What are the hazard statements for Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g?

This substance has 1 hazard statement:

  • H304: May be fatal if swallowed and enters airways.

What is the melting point of Antimony, Oil based standard solution, Specpure®, Sb 1000μg/g?

The melting point is Not determined and the boiling point is >338 ℃ (>640 °F).