NextSDS Logo
Safety Data Sheet EN

Methylcyclopentadienylmanganese tricarbonyl

CAS 12108-13-3
EC 235-166-5

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Methylcyclopentadienylmanganese tricarbonyl
Product Code
47125

Regulatory Identifiers

CAS Number
12108-13-3 Check regulations →
EC Number
235-166-5 Check regulations →

Identified Uses

SU24 Scientific research and development

Manufacturers & Suppliers

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc. logo

Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.

manufacturer

30 Bond Street, Ward Hill, MA 01835-8099

http://www.alfa.com

Emergency Contacts

Emergency Contact

(800) 343-0660

Monday-Friday, 8am-7pm EST

Carechem 24

(866) 928-0789

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Acute Tox. Cat. 2 H300
Acute Tox. Cat. 2 H310
Acute Tox. Cat. 1 H330

GHS Pictograms

GHS06 - Acute toxicity

GHS06

Hazard Statements

H300 + H310 + H330 Fatal if swallowed, in contact with skin or if inhaled.

Precautionary Statements

P260 Do not breathe dust/fume/gas/mist/vapours/spray.
P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor/...
P320 Specific treatment is urgent (see on this label).
P361 Take off immediately all contaminated clothing.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Methylcyclopentadienylmanganese tricarbonyl EC: 235-166-5 12108-13-3 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.

Skin contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

Eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

Ingestion

Do not induce vomiting; immediately call for medical help.

Immediate Medical Attention

Seek immediate medical advice.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Specific hazards

If this product is involved in a fire, the following can be released: Carbon monoxide and carbon dioxide, Metal oxide fume

Firefighter Protection

Wear self-contained respirator. Wear fully protective impervious suit.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow product to reach sewage system or any water course.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Handle under dry protective gas. Keep container tightly sealed. Ensure good ventilation at the workplace. Open and handle container with care.

Storage

Store in cool, dry place in tightly closed containers. Store away from air. Store away from oxidizing agents. Store under dry inert gas.

Fire prevention

No information known.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

Hands

Impervious gloves. Check protective gloves prior to each use for their proper condition.

Eyes

Safety glasses.

Respiratory

Use self-contained respiratory protective device in emergency situations.

Skin/Body

Protective work clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Appearance
Form: Liquid Color: Yellow
Kinematic Viscosity
Not determined
Voc Content
---
Properties Status
---
Cloud Point
---
Flash Point
96 °C (205 °F)
Metal Corrosion
---
Flammability
Not determined
Auto Ignition Temperature
Not determined
Physical State Data
liquid
Odor Threshold
Not determined
Upper Explosive Limit
Not determined
Vapor Density
Not determined
Freezing Point
---
Ph
Not determined
Vapor Pressure
Not determined
Boiling Point
233 °C (451 °F)
Solubility
Not miscible or difficult to mix
Relative Density
Not determined
Colour
Yellow
Partition Coefficient
Not determined
Lower Explosive Limit
Not determined
Solidification Point
---
Evaporation Rate
Not determined
Solubility In Water
Not miscible or difficult to mix
Density
1.388 g/cm³ (11.583 lbs/gal)
Softening Point
---
Odor
Not determined
Form
Liquid
Colour Intensity
---
Melting Point
1.5 °C (35 °F)
Bulk Density
---
Physical State
Liquid
Explosive Limits
---
Decomposition Temperature
Not determined
Molecular Weight
---
Relative Evaporation Rate
---
Dynamic Viscosity
Not determined
State Under Standard Conditions
---
Solubility In Fat
---
Crystallisation Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No information known.

Hazardous reactions

Reacts with strong oxidizing agents

Avoid

No further relevant information available.

Incompatible

Air, Oxidizing agents

Decomposition

Carbon monoxide and carbon dioxide, Metal oxide fume

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Consult state, local or national regulations to ensure proper disposal.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3281
Shipping Name
Metal carbonyls, liquid, n.o.s. (Methylcyclopentadienylmanganese tricarbonyl)
Transport Class
6.1
Packing Group
II
ADR

Warning: Toxic substances

IMDG

Warning: Toxic substances

IATA

Warning: Toxic substances

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Methylcyclopentadienylmanganese tricarbonyl?

The signal word is danger.

What is the physical form of Methylcyclopentadienylmanganese tricarbonyl?

Methylcyclopentadienylmanganese tricarbonyl is a liquid appearing as form: liquid color: yellow with yellow color. It has not determined odor.

What is the solubility of Methylcyclopentadienylmanganese tricarbonyl?

Not miscible or difficult to mix

What is Methylcyclopentadienylmanganese tricarbonyl used for?

SU24 Scientific research and development

What are the hazard statements for Methylcyclopentadienylmanganese tricarbonyl?

This substance has 1 hazard statement:

  • H300 + H310 + H330: Fatal if swallowed, in contact with skin or if inhaled.

What is the melting point of Methylcyclopentadienylmanganese tricarbonyl?

The melting point is 1.5 °C (35 °F) and the boiling point is 233 °C (451 °F).