Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Methylcyclopentadienylmanganese tricarbonyl
- Product Code
- 47125
Regulatory Identifiers
- CAS Number
- 12108-13-3 Check regulations →
- EC Number
- 235-166-5 Check regulations →
Identified Uses
SU24 Scientific research and development
Manufacturers & Suppliers
Alfa Aesar, Thermo Fisher Scientific Chemicals, Inc.
manufacturer
30 Bond Street, Ward Hill, MA 01835-8099
http://www.alfa.com
Emergency Contacts
Emergency Contact
(800) 343-0660
Monday-Friday, 8am-7pm EST
Carechem 24
(866) 928-0789
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS06
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Methylcyclopentadienylmanganese tricarbonyl EC: 235-166-5 | 12108-13-3 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.
Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.
Rinse opened eye for several minutes under running water. Then consult a doctor.
Do not induce vomiting; immediately call for medical help.
Immediate Medical Attention
Seek immediate medical advice.
Medical Treatment
No further relevant information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon dioxide, extinguishing powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
If this product is involved in a fire, the following can be released: Carbon monoxide and carbon dioxide, Metal oxide fume
Firefighter Protection
Wear self-contained respirator. Wear fully protective impervious suit.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course.
Absorb with liquid-binding material
Materials: sand, diatomite, acid binders, universal binders, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Handle under dry protective gas. Keep container tightly sealed. Ensure good ventilation at the workplace. Open and handle container with care.
Store in cool, dry place in tightly closed containers. Store away from air. Store away from oxidizing agents. Store under dry inert gas.
No information known.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.
Impervious gloves. Check protective gloves prior to each use for their proper condition.
Safety glasses.
Use self-contained respiratory protective device in emergency situations.
Protective work clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under recommended storage conditions.
No information known.
Reacts with strong oxidizing agents
No further relevant information available.
Air, Oxidizing agents
Carbon monoxide and carbon dioxide, Metal oxide fume
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Consult state, local or national regulations to ensure proper disposal.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3281
- Shipping Name
- Metal carbonyls, liquid, n.o.s. (Methylcyclopentadienylmanganese tricarbonyl)
- Transport Class
- 6.1
- Packing Group
- II
Warning: Toxic substances
Warning: Toxic substances
Warning: Toxic substances
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Methylcyclopentadienylmanganese tricarbonyl?
The signal word is danger.
What is the physical form of Methylcyclopentadienylmanganese tricarbonyl?
Methylcyclopentadienylmanganese tricarbonyl is a liquid appearing as form: liquid color: yellow with yellow color. It has not determined odor.
What is the solubility of Methylcyclopentadienylmanganese tricarbonyl?
Not miscible or difficult to mix
What is Methylcyclopentadienylmanganese tricarbonyl used for?
SU24 Scientific research and development
What are the hazard statements for Methylcyclopentadienylmanganese tricarbonyl?
This substance has 1 hazard statement:
- H300 + H310 + H330: Fatal if swallowed, in contact with skin or if inhaled.
What is the melting point of Methylcyclopentadienylmanganese tricarbonyl?
The melting point is 1.5 °C (35 °F) and the boiling point is 233 °C (451 °F).