Product Name
Neopentyl glycol diglycidyl ether
Product Code
338036
Chemical Name
1,3-bis(2,3-epoxypropoxy)-2,2-dimethylpropane 603-094-00-7

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
Laboratory chemicals, Manufacture of substances

Overview

Neopentyl glycol diglycidyl ether (CAS: 17557-23-2 ) is a colourless substance commonly used laboratory chemicals, manufacture of substances.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Irrit. Category 2 H315
Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P261: Avoid breathing dust/ fume/ gas/ mist/ vapours/ spray.
  • P264: Wash skin thoroughly after handling.
  • P272: Contaminated work clothing should not be allowed out of the workplace.
  • P280: Wear protective gloves.
  • P302 + P352: IF ON SKIN: Wash with plenty of soap and water.
  • P333 + P313: If skin irritation or rash occurs: Get medical advice/ attention.
  • P362: Take off contaminated clothing and wash before reuse.
  • P501: Dispose of contents/ container to an approved waste disposal plant.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Sigma-Aldrich

manufacturer

📍

3050 Spruce Street, SAINT LOUIS MO 63103, USA

🌍

US

📞

+1 800-325-5832

📠

+1 800-325-5052

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

📞

+1-703-527-3887

🌍

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
1,3-bis(2,3-epoxypropoxy)-2,2-dimethylpropane 603-094-00-7
EC: 241-536-7
17557-23-2 100% ⚠️ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

🖐️ Skin Contact

Wash off with soap and plenty of water. Consult a physician.

👁️ Eye Contact

Flush eyes with water as a precaution.

🍽️ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

📊 Physical State Data
liquid
🔥 Flash Point
113 °℃ (235 °F) - closed cup
Critical Property
📊 Crystallisation Point
Not available
👁️ Appearance
colourless
📊 Vapor Density
7.47 - (Air = 1.0)
📊 Softening Point
Not available
📊 Partition Coefficient
Not available
📊 Properties Status
Not available
📊 Relative Density
1.04 g/cm3 at 25 ℃ (77 ºF)
📊 Explosive Limits
Not available
💧 Solubility
Not available
🧪 Physical State
liquid
Critical Property
📊 Upper Explosive Limit
Not available
📊 Solubility In Water
Not available
📊 Metal Corrosion
Not available
📊 Decomposition Temperature
Not available
📊 Voc Content
Not available
🧊 Melting Point
Not available
🧪 Ph
Not available
📊 Dynamic Viscosity
Not available
🔥 Flammability
Not available
💨 Evaporation Rate
Not available
🎨 Colour
colourless
💨 Vapor Pressure
Not available
📊 Molecular Weight
Not available
👃 Odor
Not available
📊 Solubility In Fat
Not available
📊 Bulk Density
Not available
📊 Solidification Point
Not available
📊 Colour Intensity
Not available
📊 Freezing Point
Not available
📊 Lower Explosive Limit
Not available
📊 Kinematic Viscosity
Not available
📊 Auto Ignition Temperature
Not available
⚖️ Density
Not available
📊 Odor Threshold
Not available
📊 Cloud Point
Not available
📊 Form
liquid
📊 Relative Evaporation Rate
Not available
📊 State Under Standard Conditions
Not available
💨 Boiling Point
103 - 107 ℃ (217 - 225 °F) at 1 hPa (1 mmHg) - lit.
Critical Property

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.

🧤 Hand Protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

👁️ Eye Protection

Face shield and safety glasses Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

😷 Respiratory Protection

Where risk assessment shows air-purifying respirators are appropriate use a full-face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

🌍 Environmental Exposure Controls

Do not let product enter drains.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Neopentyl glycol diglycidyl ether?

The signal word for this substance is "warning".

What is the physical form of Neopentyl glycol diglycidyl ether?

Neopentyl glycol diglycidyl ether is a liquid appearing as colourless with colourless color.

What is Neopentyl glycol diglycidyl ether used for?

Laboratory chemicals, Manufacture of substances

What are the hazard statements for Neopentyl glycol diglycidyl ether?

This substance has 2 hazard statements: H315: Causes skin irritation. H317: May cause an allergic skin reaction.