NextSDS Logo
Pl

Platinum(IV) chloride

DANGER SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Platinum(IV) chloride
Product Code
11045

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

Platinum(IV) chloride is a general information substance commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 3 H301
Resp. Sens. Category 1 H334
Skin Corr. Category 1B H314
Eye Dam. Category 1 H318
Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS06 GHS Hazard Pictogram: Acute toxicity hazard - Poisonous materials that can cause death or serious harm

GHS06

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H301: Toxic if swallowed.
  • H314: Causes severe skin burns and eye damage.
  • H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled.
  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P260: Do not breathe dust/fume/gas/mist/vapours/spray.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/ doctor/.
  • P303+P361+P353: If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

๐Ÿ“

30 Bond Street, Ward Hill, MA 01835-8099

๐ŸŒ

US

๐Ÿ“ž

800-343-0660

๐Ÿ“ 

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

(800) 343-0660

๐Ÿ•’

Monday-Friday, 8am-7pm EST

Carechem 24

๐Ÿ“ž

(866) 928-0789

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Platinum(IV) chloride
EC: 236-645-1
13454-96-1 Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Seek medical treatment.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Use fire-fighting measures that suit the surrounding fire.

โš ๏ธ Specific Fire Hazards

If this product is involved in a fire, the following can be released: Hydrogen chloride (HCI), Platinum oxide.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Wear self-contained respirator. Wear fully protective impervious suit.

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

Wear protective equipment. Keep unprotected persons away. Ensure adequate ventilation.

๐ŸŒ Environmental Precautions

Do not allow product to reach sewage system or any water course.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
General Information
๐ŸŽจ Colour
Orange to brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Crystalline
๐Ÿ‘ƒ Odor
Odorless
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not applicable.
๐ŸงŠ Melting Point
370 ยฐC (698 ยฐF) (dec)
Critical Property
๐Ÿ’จ Boiling Point
Not determined
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable.
๐Ÿ’จ Vapor Pressure
Not applicable.
๐Ÿ“Š Vapor Density
Not applicable.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
4.303 g/cm3 (35.909 lbs/gal)
Critical Property
๐Ÿ”ฅ Flammability
Not determined.
๐Ÿ“Š Upper Explosive Limit
Not determined
๐Ÿ“Š Lower Explosive Limit
Not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not determined.
๐Ÿ“Š Decomposition Temperature
Not determined
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
587 g/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Handle under dry protective gas.

โ€ข Keep container tightly sealed.

โ€ข Store in cool, dry place in tightly closed containers.

โ€ข Ensure good ventilation at the workplace.

โ€ข Prevent formation of dust.

๐Ÿช Storage Conditions

โ€ข Store away from water/moisture.

โ€ข Store away from oxidizing agents.

โ€ข Store under dry inert gas.

โ€ข This product is hygroscopic.

โ€ข Keep container tightly sealed.

โ€ข Store in cool, dry conditions in well sealed containers.

๐Ÿ”ฅ Fire Prevention Measures

The product is not flammable.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

๐Ÿงค Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Nitrile rubber, NBR. Penetration time of glove material (in minutes) 480. Glove thickness 0.11 mm.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles. Full face protection.

๐Ÿ˜ท Respiratory Protection

Use suitable respirator when high concentrations are present. Recommended filter device for short term use: Use a respirator with type P100 (USA) or P3 (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. Only use equipment tested and approved under appropriate government standards.

๐Ÿฆบ Skin/Body Protection

Protective work clothing.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

Stable under recommended storage conditions.

โš—๏ธ Reactivity

No information known.

โš ๏ธ Hazardous Reactions

Reacts with strong oxidizing agents

๐Ÿšซ Conditions to Avoid

No further relevant information available.

๐Ÿงช Incompatible Materials

Water/moisture, Oxidizing agents

๐Ÿ’จ Hazardous Decomposition Products

Hydrogen chloride (HCI), Platinum oxide

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

Aquatic toxicity: No further relevant information available.

๐ŸŒฑ Persistence and degradability

No further relevant information available.

๐ŸŒฑ Bioaccumulative potential

No further relevant information available.

๐ŸŒฑ Mobility in soil

No further relevant information available.

๐ŸŒฑ Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

๐ŸŒฑ Other adverse effects

No further relevant information available.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Consult state, local or national regulations to ensure proper disposal.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Disposal must be made according to official regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN2923

๐Ÿ“ฆ Proper Shipping Name

Corrosive solids, toxic, n.o.s. (Platinum(IV) chloride)

โš ๏ธ Transport Hazard Class

8 Corrosive substances.

๐Ÿ“‹ Packing Group

III

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Corrosive substances

โœˆ๏ธ IATA Air Transport Precautions

Warning: Corrosive substances

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

All components of this product are listed in the U.S. Environmental Protection Agency Toxic Substances Control Act Chemical substance Inventory. All components of this product are listed on the Canadian Domestic Substances List (DSL).

โŒ Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

โ„น๏ธ Additional Regulatory Information

Employers should use this information only as a supplement to other information gathered by them, and should make independent judgement of suitability of this information to ensure proper use and protect the health and safety of employees.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Platinum(IV) chloride?

The signal word for this substance is "danger".

What is Platinum(IV) chloride used for?

SU24 Scientific research and development

What are the hazard statements for Platinum(IV) chloride?

This substance has 4 hazard statements: H301: Toxic if swallowed. H314: Causes severe skin burns and eye damage. H334: May cause allergy or asthma symptoms or breathing difficulties if inhaled. H317: May cause an allergic skin reaction.

What is the melting point of Platinum(IV) chloride?

The melting point is 370 ยฐC (698 ยฐF) (dec) and the boiling point is Not determined.