NextSDS Logo
DE

DERMABIO M

WARNING liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DERMABIO M
Product Code
316108

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
UU21-C0DS-S00G-9PKG

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
AUXILIARY FOR TANNING INDUSTRY
Uses Advised Against
Do not use in any processing different from above mentioned

Overview

DERMABIO M is a limpid liquid substance commonly used auxiliary for tanning industry.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Eye Irrit. Category 2 H319

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H319: Causes serious eye irritation.
  • EUH208: May produce an allergic reaction.

Precautionary Statements

  • P280: Wear eye protection / face protection.
  • P337+P313: If eye irritation persists: Get medical advice / attention.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

DERMACOLOR S.R.L.

manufacturer

๐Ÿ“

Via del Frassino 5, 56022 Castelfranco di Sotto Italia

๐ŸŒ

IT

๐Ÿ“ž

+39 0571 471313

๐Ÿ“ 

+39 0571 471326

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

DERMACOLOR S.R.L.

๐Ÿ“ž

+39 0571 471313

๐ŸŒ

IT

Marco Marano CAV Roma

๐Ÿ“ž

06 68593726

๐ŸŒ

IT

Anna Lepore Az.Osp. Foggia

๐Ÿ“ž

800183459

๐ŸŒ

IT

Romolo Villani Az.Osp. Napoli

๐Ÿ“ž

0815453333

๐ŸŒ

IT

M. Caterina Grassi CAV Roma

๐Ÿ“ž

0649978000

๐ŸŒ

IT

Alessandro Barelli CAV Roma

๐Ÿ“ž

063054343

๐ŸŒ

IT

Francesco Gambassi Az.Osp. Firenze

๐Ÿ“ž

0557947819

๐ŸŒ

IT

Carlo Locatelli CAV Pavia

๐Ÿ“ž

038224444

๐ŸŒ

IT

Franca Davanzo Osp. Milano

๐Ÿ“ž

0266101029

๐ŸŒ

IT

Bacis Giuseppe Az.Osp. Bergamo

๐Ÿ“ž

800883300

๐ŸŒ

IT

Giorgio Ricci Az.Osp. Verona

๐Ÿ“ž

800011858

๐ŸŒ

IT

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

General Composition

Contains various chemical components including Ethanol, Propan-2-ol, Methyl Ethyl Ketone, Lipase, 1,2-Benzoisothiazol-3(2H)-one, and C (M) IT / MIT (3: 1).

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
ETHANOL
EC: 200-578-6
64-17-5 3.2-13.2% โš ๏ธ Hazardous
PROPAN-2-OL
EC: 200-661-7
67-63-0 0.4-1.4% โš ๏ธ Hazardous
METHYL ETHYL KETONE
EC: 201-159-0
78-93-3 0.09% โš ๏ธ Hazardous
lipase
EC: 232-619-9
9001-62-1 0.013% โš ๏ธ Hazardous
1,2-Benzoisothiazol-3(2H)-one
EC: 220-120-9
2634-33-5 0.011% โš ๏ธ Hazardous
C (M) IT / MIT (3: 1) 55965-84-9 0.00039% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Get medical advice/attention immediately. Remove victim to fresh air, away from the accident scene. If the subject stops breathing, administer artificial respiration. Take suitable precautions for rescue workers.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing. Rinse skin with a shower immediately. Get medical advice/attention.

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, if present. Wash immediately with plenty of water for at least 30-60 minutes, opening the eyelids fully. Get medical advice/attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Have the subject drink as much water as possible. Get medical advice/attention. Do not induce vomiting unless explicitly authorised by a doctor.

๐Ÿšจ Immediate Medical Attention Required

In the event of disease, exposure or possible exposure: consult a physician or an antipoison centre.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

โœ… Suitable Extinguishing Media

Extinguishing substances are: carbon dioxide, foam, chemical powder. For product loss or leakage that has not caught fire, water spray can be used to disperse flammable vapours and protect those trying to stem the leak.

โŒ Unsuitable Extinguishing Media

Do not use jets of water. Water is not effective for putting out fires but can be used to cool containers exposed to flames to prevent explosions.

โš ๏ธ Specific Fire Hazards

Excess pressure may form in containers exposed to fire at a risk of explosion. Do not breathe combustion products.

๐Ÿ”ฅ Fire Fighting Instructions

Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health. Always wear full fire prevention gear. Collect extinguishing water to prevent it from draining into the sewer system. Dispose of contaminated water used for extinction and the remains of the fire according to applicable regulations.

๐Ÿ›ก๏ธ Firefighter Protection Equipment

Normal fire fighting clothing i.e. fire kit (BS EN 469), gloves (BS EN 659) and boots (HO specification A29 and A30) in combination with self-contained open circuit positive pressure compressed air breathing apparatus (BS EN 137).

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

๐Ÿšจ Emergency Procedures

Block the leakage if there is no hazard.

๐ŸŒ Environmental Precautions

The product must not penetrate into the sewer system or come into contact with surface water or ground water.

๐Ÿงน Cleanup Methods

Absorb the remainder with inert absorbent material.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
limpid liquid
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
mild
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
5.5-7.0
๐ŸงŠ Melting Point
Not determined
Critical Property
๐Ÿ’จ Boiling Point
60 โ„ƒ
Critical Property
๐Ÿ”ฅ Flash Point
Combustion not sustained.
Critical Property
๐Ÿ“Š Freezing Point
Not determined
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0,992
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
not relevant because liquid
๐Ÿ“Š Upper Explosive Limit
Not determined
๐Ÿ“Š Lower Explosive Limit
Not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not determined
๐Ÿ“Š Decomposition Temperature
Not determined
๐Ÿ’ง Solubility
emulsifiable
๐Ÿ“Š Partition Coefficient
Not determined
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

โš ๏ธ Handling Precautions

โ€ข Keep away from heat, sparks and naked flames; do not smoke or use matches or lighters.

โ€ข Without adequate ventilation, vapours may accumulate at ground level and, if ignited, catch fire even at a distance, with the danger of backfire.

โ€ข Avoid bunching of electrostatic charges.

โ€ข When performing transfer operations involving large containers, connect to an earthing system and wear antistatic footwear.

โ€ข Vigorous stirring and flow through the tubes and equipment may cause the formation and accumulation of electrostatic charges.

โ€ข In order to avoid the risk of fires and explosions, never use compressed air when handling.

โ€ข Open containers with caution as they may be pressurised.

โ€ข Do not eat, drink or smoke during use.

โ€ข Avoid leakage of the product into the environment.

๐Ÿช Storage Conditions

โ€ข Store only in the original container.

โ€ข Keep containers away from any incompatible materials.

๐Ÿงผ General Hygiene Measures

Do not eat, drink or smoke during use.

๐Ÿ”ฅ Fire Prevention Measures

Store the containers sealed, in a well ventilated place, away from direct sunlight. Store in a cool and well ventilated place, keep far away from sources of heat, naked flames and sparks and other sources of ignition.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

As the use of adequate technical equipment must always take priority over personal protective equipment, make sure that the workplace is well aired through effective local aspiration.

๐Ÿงค Hand Protection

Protect hands with category III work gloves (see standard EN 374). The following should be considered when choosing work glove material: compatibility, degradation, failure time and permeability. The work gloves' resistance to chemical agents should be checked before use, as it can be unpredictable. The gloves' wear time depends on the duration and type of use.

๐Ÿ‘๏ธ Eye Protection

Wear airtight protective goggles (see standard EN 166).

๐Ÿ˜ท Respiratory Protection

If the threshold value (e.g. TLV-TWA) is exceeded for the substance or one of the substances present in the product, wear a mask with a type AX filter, whose limit of use will be defined by the manufacturer (see standard EN 14387). In the presence of gases or vapours of various kinds and/or gases or vapours containing particulate (aerosol sprays, fumes, mists, etc.) combined filters are required. Respiratory protection devices must be used if the technical measures adopted are not suitable for restricting the worker's exposure to the threshold values considered. The protection provided by masks is in any case limited. If the substance considered is odourless or its olfactory threshold is higher than the corresponding TLV-TWA and in the case of an emergency, wear open-circuit compressed air breathing apparatus (in compliance with standard EN 137) or external air-intake breathing apparatus (in compliance with standard EN 138). For a correct choice of respiratory protection device, see standard EN 529.

๐Ÿฆบ Skin/Body Protection

Wear category I professional long-sleeved overalls and safety footwear (see Regulation 2016/425 and standard EN ISO 20344). Wash body with soap and water after removing protective clothing.

๐ŸŒ Environmental Exposure Controls

The emissions generated by manufacturing processes, including those generated by ventilation equipment, should be checked to ensure compliance with environmental standards. For information on controlling environmental exposure, see the exposure scenarios attached to this safety datasheet.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

โœ… Chemical Stability

The product is stable in normal conditions of use and storage.

โš—๏ธ Reactivity

There are no particular risks of reaction with other substances in normal conditions of use. METHYL ETHYL KETONE Reacts with: light metals,strong oxidants.Attacks various types of plastic materials.Decomposes under the effect of heat.

โš ๏ธ Hazardous Reactions

The vapours may also form explosive mixtures with the air. METHYL ETHYL KETONE May form peroxides with: air,light,strong oxidising agents.Risk of explosion on contact with: hydrogen peroxide, nitric acid,sulphuric acid.May react dangerously with: oxidising agents,trichloromethane, alkalis.Forms explosive mixtures with: air.

๐Ÿšซ Conditions to Avoid

Avoid overheating. Avoid bunching of electrostatic charges. Avoid all sources of ignition. ETHANOL Avoid exposure to: sources of heat, naked flames. METHYL ETHYL KETONE Avoid exposure to: sources of heat.

๐Ÿงช Incompatible Materials

METHYL ETHYL KETONE Incompatible with: strong oxidants,inorganic acids, ammonia, copper,chloroform.

๐Ÿ’จ Hazardous Decomposition Products

In the event of thermal decomposition or fire, gases and vapours that are potentially dangerous to health may be released. No decomposition expected if the product is properly handled.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

๐ŸŒฑ Toxicity

1,2-Benzoisothiazol-3(2H)-one LC50 - for Fish EC50 - for Crustacea EC50 - for Algae / Aquatic Plants > 0,1 mg/l/72h C (M) IT / MIT (3: 1) LC50 - for Fish 0,19 mg/l/96h Oncorhynchus mykiss EC50 - for Crustacea 0,1 mg/l/48h Daphnia Magna EC50 - for Algae / Aquatic Plants 0,037 mg/l/72h Pseudokirchneriella subcapitata Chronic NOEC for Fish 0,098 mg/l Oncorhyncus mykiss Chronic NOEC for Crustacea 0,004 mg/l Daphnia magna Chronic NOEC for Algae / Aquatic Plants 0,0012 mg/l Pseudokirchneriella subcapitata ETHANOL LC50 - for Fish > 7000 mg/l/96h PROPAN-2-OL LC50 - for Fish > 9640 mg/l/96h Pimephales promelas, OECD Guideline 203 METHYL ETHYL KETONE LC50 - for Fish EC50 - for Crustacea EC50 - for Algae / Aquatic Plants 2993 mg/l/96h Pimephales promelas 308 mg/l/48h Daphnia magna 1972 mg/l/72h Pseudokirchnerella subcapitata lipase LC50 - for Fish EC50 - for Crustacea > 68,3 mg/l/96h OECD TG 203 > 37,4 mg/l/48h OECD TG 202 EC50 - for Algae / Aquatic Plants > 18 mg/l/72h OECD TG 201

๐ŸŒฑ Persistence and degradability

C (M) IT / MIT (3: 1) Solubility in water Entirely degradable 2 mg/l/96h Oncorhynchus mykiss > 2 mg/l/48h Daphnia magna EN > 10000 mg/l

๐ŸŒฑ Bioaccumulative potential

C (M) IT / MIT (3: 1) Partition coefficient: n-octanol/water 0,75 Log Kow ETHANOL Partition coefficient: n-octanol/water -0,35 PROPAN-2-OL Partition coefficient: n-octanol/water 0,05 METHYL ETHYL KETONE Partition coefficient: n-octanol/water 0,3

๐ŸŒฑ Mobility in soil

Information not available

๐ŸŒฑ Results of PBT and vPvB assessment

On the basis of available data, the product does not contain any PBT or vPvB in percentage โ‰ฅ than 0,1%.

๐ŸŒฑ Endocrine disrupting properties

Based on the available data, the product does not contain substances listed in the main European lists of potential or suspected endocrine disruptors with environmental effects under evaluation.

๐ŸŒฑ Other adverse effects

No other known adverse effects other than those listed above.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

โ™ป๏ธ Waste Treatment Methods

Reuse, when possible. Product residues should be considered special hazardous waste. The hazard level of waste containing this product should be evaluated according to applicable regulations.

๐Ÿ—‚๏ธ Product Disposal Recommendations

Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

๐Ÿ“‹ Regulatory Summary

The product does not contain any SVHC in percentage โ‰ฅ than 0, 1%.

โœ… Chemical Safety Assessment

Chemical safety assessment has been performed for this substance.

โ„น๏ธ Additional Regulatory Information

Workers exposed to this chemical agent must not undergo health checks, provided that available risk-assessment data prove that the risks related to the workers' health and safety are modest and that the 98/24/EC directive is respected.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DERMABIO M?

The signal word for this substance is "warning".

What is the physical form of DERMABIO M?

DERMABIO M is a liquid appearing as limpid liquid with colourless color. It has mild odor.

What is the solubility of DERMABIO M?

emulsifiable

What is DERMABIO M used for?

AUXILIARY FOR TANNING INDUSTRY

What are the hazard statements for DERMABIO M?

This substance has 2 hazard statements: H319: Causes serious eye irritation. EUH208: May produce an allergic reaction.

What is the melting point of DERMABIO M?

The melting point is Not determined and the boiling point is 60 โ„ƒ.