NextSDS Logo
Safety Data Sheet EN

Titanium(IV) oxide

CAS 13463-67-7

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Titanium(IV) oxide
Product Code
718467
Chemical Name
Titanium Dioxide

Regulatory Identifiers

CAS Number
13463-67-7 Check regulations →

Identified Uses

Laboratory chemicals, Manufacture of substances

Manufacturers & Suppliers

M

Merck Life Science BV/SRL

manufacturer

Brusselsesteenweg 288, B-3090 OVERIJSE

+32 (0)3 899-1301

Emergency Contacts

CHEMTREC

+(32) 28 083237

Anti-poison centre

070 245245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
titaniumdioxide; [in poedervorm, bevattend: 1 % of meer deeltjes met een aerodynamische diameter ≤ 10 µm] EC: 236-675-5 13463-67-7 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN 16523-1 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de). Full contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0,11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Respiratory protection is not required. Where protection from nuisance levels of dusts are desired, use type N95 (US) or type P1 (EN 143) dust masks. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or EN 14387 (EU).

Skin/Body

protective clothing

Environmental

No special precautionary measures necessary.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
nano particles
Physical State Data
---
State Under Standard Conditions
---
Appearance
---
Colour
white
Colour Intensity
---
Form
---
Odor
No data available
Odor Threshold
---
Ph
No data available
Melting Point
1.850 ℃
Boiling Point
No data available
Flash Point
Not applicable
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
No data available
Vapor Density
---
Relative Density
No data available
Bulk Density
---
Density
No data available
Flammability
No data available
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
---
Partition Coefficient
Not applicable for inorganic substances
Solubility In Water
No data available
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
718467
Shipping Name
Not dangerous goods
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Titanium(IV) oxide?

The signal word is no signal word.

What is the physical form of Titanium(IV) oxide?

Titanium(IV) oxide is a nano particles with white color. It has no data available odor.

What is Titanium(IV) oxide used for?

Laboratory chemicals, Manufacture of substances

What is the melting point of Titanium(IV) oxide?

The melting point is 1.850 ℃ and the boiling point is No data available.