NextSDS Logo
Safety Data Sheet EN

Buffer Solution, pH 7.00

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Buffer Solution, pH 7.00
Product Code
63056125, 63056122, 63056116

Regulatory Identifiers

CAS Number
N/A

Identified Uses

professional, scientific and technical activities: other professional, scientific and technical activities

Uses advised against

None known.

Manufacturers & Suppliers

G

GFS Chemicals, Inc.

manufacturer

800 Kaderly Drive, Columbus, OH 43228

Mettler Toledo logo

Mettler Toledo

distributor

1900 Polaris Parkway, Columbus, OH 43240

1-800-METTLER, 1-800-638-8537

http://www.mt.com/pH

Emergency Contacts

Chemtrec

800-424-9300

Chemtrec

1-703-741-5970

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Hazard Statements

The mixture does not meet the criteria for classification.

Precautionary Statements

P233 Keep container tightly closed.
P264 Wash hands after handling.
P501 Dispose of waste and residues in accordance with local authority requirements.
Observe good industrial hygiene practices.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Other components below reportable levels < 0.1

Chemical Name CAS Number Concentration Hazardous
WATER 7732-18-5 99% No
POTASSIUM PHOSPHATE, MONOBASIC 7778-77-0 1% No
SODIUM PHOSPHATE, DIBASIC 7558-79-4 1% No

Other components below reportable levels: < 0.1

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Call a physician if symptoms develop or persist.

Skin contact

Wash off with soap and water. Get medical attention if irritation develops and persists.

Eye contact

Rinse with water. Get medical attention if irritation develops and persists.

Symptoms: Direct contact with eyes may cause temporary irritation.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

Treat symptomatically.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing agent suitable for type of surrounding fire.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

None known.

Instructions

Move containers from fire area if you can do so without risk.

Firefighter Protection

Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep unnecessary personnel away.

Small spill

Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Large spill

Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Dilute with water. Flush to sewer if local regulations permit. Following product recovery, flush area with water.

Environmental

Avoid discharge into drains, water courses or onto the ground.

Cleanup methods

Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Materials: absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Observe good industrial hygiene practices.

Storage

Store in tightly closed container. Store away from incompatible materials (see Section 10 of the SDS). Keep containers tightly closed.

Hygiene

Observe good industrial hygiene practices.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Wear appropriate chemical resistant gloves.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Wear suitable protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Flammability
Not applicable.
Dynamic Viscosity
---
Solubility
---
Partition Coefficient
Not available.
Solubility In Fat
---
Lower Explosive Limit
Not available.
Kinematic Viscosity
---
Solidification Point
---
Vapor Pressure
Not available.
Appearance
Clear.
Bulk Density
---
Voc Content
---
Physical State Data
liquid
Evaporation Rate
Not available.
Vapor Density
Not available.
Melting Point
32 °F (0 °C) estimated
Relative Evaporation Rate
---
State Under Standard Conditions
---
Auto Ignition Temperature
Not available.
Odor Threshold
Not available.
Molecular Weight
---
Properties Status
---
Solubility In Water
Miscible
Metal Corrosion
---
Cloud Point
---
Form
Liquid.
Boiling Point
212 °F (100 °C) estimated
Colour
Yellow.
Ph
7.00
Crystallisation Point
---
Physical State
Liquid.
Upper Explosive Limit
Not available.
Freezing Point
32 °F (0 °C) estimated
Colour Intensity
---
Decomposition Temperature
Not available.
Relative Density
Not available.
Density
1.00 g/cm3
Explosive Limits
---
Softening Point
---
Odor
Odorless.
Flash Point
Not available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is stable and non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

Hazardous polymerization does not occur.

Avoid

None known. Contact with incompatible materials.

Incompatible

None known.

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Collect and reclaim or dispose in sealed containers at licensed waste disposal site.

Disposal

Dispose of in accordance with local regulations. This material and its container must be disposed of in a safe manner.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

This product is not known to be a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Buffer Solution, pH 7.00?

The signal word is no signal word.

What is the physical form of Buffer Solution, pH 7.00?

Buffer Solution, pH 7.00 is a liquid. appearing as clear. with yellow. color. It has odorless. odor.

What is Buffer Solution, pH 7.00 used for?

professional, scientific and technical activities: other professional, scientific and technical activities

What are the hazard statements for Buffer Solution, pH 7.00?

This substance has 1 hazard statement:

  • The mixture does not meet the criteria for classification.

What is the melting point of Buffer Solution, pH 7.00?

The melting point is 32 °F (0 °C) estimated and the boiling point is 212 °F (100 °C) estimated.