NextSDS Logo
AC

ACCUMULATOR

WARNING Solid, High-pressure gas at 20 SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
ACCUMULATOR

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Accumulator
Uses Advised Against
Foodstuffs

Overview

ACCUMULATOR commonly used accumulator.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Press. Gas

GHS Hazard Pictograms & Safety Symbols

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H280: Contains gas under pressure ; may explode if heated

Precautionary Statements

  • P410+P403: Protect from sunlight. Store in a well-ventilated place.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

XOL Co., Ltd. company logo - Safety Data Sheet supplier organization

XOL Co., Ltd.

manufacturer

๐Ÿ“

#478-59, Gagok-ro, Gamgok-myeon, Eumseong-gun, Chungcheongbuk-do, Republic of Korea

๐ŸŒ

KR

๐Ÿ“ž

+82 43 750 7440

๐Ÿ“ 

+82 43 750 7441

๐ŸŒ www.xol.co.kr

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Iron
EC: 231-096-4
7439-89-6 95% โœ“ Non-hazardous
2-Propenenitrile, polymer with 1,3-butadiene, hydrogenated 88254-10-8 5% โœ“ Non-hazardous
Nitrogen
EC: 231-783-9
7727-37-9 2% โœ“ Non-hazardous
Carbon black
EC: 215-609-9
1333-86-4 0.1% โœ“ Non-hazardous
Etc. N/A 3% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.

๐Ÿ–๏ธ Skin Contact

Get immediate medical advice/attention.

๐Ÿ‘๏ธ Eye Contact

Get immediate medical advice/attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

๐Ÿšจ Immediate Medical Attention Required

Get immediate medical advice/attention. Consult a physician.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid, High-pressure gas at 20
Critical Property
๐Ÿ“Š Physical State Data
gas
๐Ÿ“Š State Under Standard Conditions
Solid, High-pressure gas at 20
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
6.5 ~ 7.5 at 20 Sample : H 2 O = 1 : 5 (V/V)
๐ŸงŠ Melting Point
- 210 (Nitrogen) from NLM / HSDB
Critical Property
๐Ÿ’จ Boiling Point
- 196 (Nitrogen) from NLM / HSDB
Critical Property
๐Ÿ”ฅ Flash Point
No flash occurred under 93 (Rapid equilibrium method)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
No data available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
> 7.0 at 20
Critical Property
๐Ÿ”ฅ Flammability
Non flammable gas from NLM HSDB
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No spontaneous combustion under 200
๐Ÿ“Š Decomposition Temperature
No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
Water Insoluble at 20
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available
๐Ÿ“Š Kinematic Viscosity
No data available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation

๐Ÿงค Hand Protection

Chemical resistant gloves

๐Ÿ‘๏ธ Eye Protection

Protective goggles

๐Ÿ˜ท Respiratory Protection

Approved respirator

๐Ÿฆบ Skin/Body Protection

Working clothes

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1066

๐Ÿ“ฆ Proper Shipping Name

NITROGEN, COMPRESSED

โš ๏ธ Transport Hazard Class

2.2

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for ACCUMULATOR?

The signal word for this substance is "warning".

What is the physical form of ACCUMULATOR?

ACCUMULATOR is a solid, high-pressure gas at 20 .

What is ACCUMULATOR used for?

Accumulator

What are the hazard statements for ACCUMULATOR?

This substance has 1 hazard statements: H280: Contains gas under pressure ; may explode if heated

What is the melting point of ACCUMULATOR?

The melting point is - 210 (Nitrogen) from NLM / HSDB and the boiling point is - 196 (Nitrogen) from NLM / HSDB.