NextSDS Logo
In

Interflon Fin Grease (aerosol)

DANGER SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Interflon Fin Grease (aerosol)
Product Form
aerosol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubricant

Overview

Interflon Fin Grease (aerosol) commonly used lubricant.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Aerosol Category 1 H222
Aerosol Category 1 H229
Asp. Tox. Category 1 H304
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P251: Do not pierce or burn, even after use.
  • P211: Do not spray on an open flame or other ignition source.
  • P273: Avoid release to the environment.
  • P410+P412: Protect from sunlight. Do not expose to temperatures exceeding 50 C/122 F.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Interflon b.v. company logo - Safety Data Sheet supplier organization

Interflon b.v.

manufacturer

๐Ÿ“

P.O. Box 1070 NL-4700 BB Roosendaal The Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+31(0)165.55.39.11

๐Ÿ“ 

+31(0)165.53.80.82

๐ŸŒ www.interflon.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

UK National Poisons Emergency number

๐Ÿ“ž

+44 870 600 6266

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Blend of mineral oils, inorganic thickener, solvent, additives and Teflon. Propellant gas propane, butane and isobutane.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
butane
EC: 203-448-7
106-97-8 10-25% โš ๏ธ Hazardous
propane
EC: 200-827-9
74-98-6 10-25% โš ๏ธ Hazardous
isobutane
EC: 200-857-2
75-28-5 10-25% โš ๏ธ Hazardous
Hydrocarbons, C7-C9, isoalkanes
EC: 921-728-3
N/A 2.5-10% โš ๏ธ Hazardous
Hydrocarbons, C10-C12, isoalkanes, <2% aromatics
EC: 923-037-2
N/A 2.5-10% โš ๏ธ Hazardous

Additional Information

Note: Any entry in the EC column that begins with the number "9" is a Provisional List Number provided by ECHA pending publication of the official EC Inventory Number for the substance. See Section 16 for additional CAS number information for the substance. For the wording of the listed risk phrases refer to section 16.

Composition Notes

This product does not contain "very worrisome substances" (SVHC) that are very dangerous to human health or the environment. (SVHC <0.1% (w / w) Regulation (EC) No. 1907/2006 (REACH), Article 57).

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

๐Ÿฝ๏ธ Ingestion/Swallowing

If symptoms persist consult doctor.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
White
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Aerosol
๐Ÿ‘ƒ Odor
Recognisable
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not applicable.
๐ŸงŠ Melting Point
Not applicable.
Critical Property
๐Ÿ’จ Boiling Point
< 0 C
Critical Property
๐Ÿ”ฅ Flash Point
< -60 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable.
๐Ÿ’จ Vapor Pressure
3800 hPa
๐Ÿ“Š Vapor Density
1.6 - 2.0 g/cm
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.65 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Flammable.
๐Ÿ“Š Upper Explosive Limit
10.0 Vol %
๐Ÿ“Š Lower Explosive Limit
1.5 Vol %
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
> 360 C
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Not miscible or difficult to mix.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not applicable.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation or extraction.

๐Ÿงค Hand Protection

No chemical-protective gloves required. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Not required. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Practical experience has shown that gloves of neoprene, Nitril and PVC offer sufficient protection. Breakthrough time: < 60 minutes. Not required. The penetration times are not determined by method EN 374 Part 3.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles (EN166)

๐Ÿ˜ท Respiratory Protection

Do not breathe vapour and sprayer mist. Ventilation or extraction. Use suitable respiratory protective device in case of insufficient ventilation.

๐Ÿฆบ Skin/Body Protection

Protective work clothing (EN340)

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1950

๐Ÿ“ฆ Proper Shipping Name

AEROSOLS

โš ๏ธ Transport Hazard Class

2.1

๐Ÿ“‹ Packing Group

Void

๐Ÿš› ADR Transport Precautions

Warning: Gases.

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Gases.

โœˆ๏ธ IATA Air Transport Precautions

Warning: Gases.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Interflon Fin Grease (aerosol)?

The signal word for this substance is "danger".

What is Interflon Fin Grease (aerosol) used for?

Lubricant

What are the hazard statements for Interflon Fin Grease (aerosol)?

This substance has 3 hazard statements: H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Interflon Fin Grease (aerosol)?

The melting point is Not applicable. and the boiling point is < 0 C.