NextSDS Logo
Safety Data Sheet EN

Interflon Food Grease 000

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Interflon Food Grease 000

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricant

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

I

Interflon b.v.

manufacturer

P.O. Box 1070, NL-4700 BB Roosendaal, The Netherlands

+31(0)165.55.39.11

Emergency Contacts

Emergency Contact

+31 (0)165 55 39 11

Monday to Friday from 8:30am to 17:00pm

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Blend of mineral oils, inorganic thickener, additives and Teflon®.

Chemical Name CAS Number Concentration Hazardous
mineral oils --- --- No
inorganic thickener --- --- No
additives --- --- No
Teflon® --- --- No

See SDS Section 16 for full text of hazard statements.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Generally the product does not irritate the skin.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

If symptoms persist consult doctor.

Immediate Medical Attention

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions. CO2, sand, extinguishing powder. Foam.

Unsuitable media

Water

Specific hazards

Formation of toxic gases is possible during heating or in case of fire.

Firefighter Protection

Wear self-contained respiratory protective device. Use personal protective equipment (EN469).

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Clear spills immediately.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Remove residues with alkaline cleaning agent.

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

Store in accordance with local/regional/national/international regulations. Keep container tightly closed. Store in a dry place.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

No chemical-protective gloves required. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Not required. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Practical experience has shown that gloves of neoprene, Nitril and PVC offer sufficient protection. Breakthrough time: < 60 minutes. Penetration time of glove material: Not required. The penetration times are not determined by method EN 374 Part 3.

Eyes

Goggles (EN166) recommended during refilling

Respiratory

Not required.

Skin/Body

Wear suitable protective clothing (EN ISO 13688).

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State Data
liquid
Odor
Odourless
Dynamic Viscosity
4750 mPas
Vapor Density
Not determined.
Softening Point
---
Solubility In Fat
---
Evaporation Rate
Not determined.
Melting Point
Not applicable.
Form
Fluid
Relative Evaporation Rate
---
Appearance
---
Colour Intensity
---
Solidification Point
---
Freezing Point
Not applicable.
Partition Coefficient
---
Solubility In Water
Not miscible or difficult to mix.
Auto Ignition Temperature
Product is not selfigniting.
Properties Status
---
Colour
White
Voc Content
---
Density
0.93 g/cm³
State Under Standard Conditions
---
Molecular Weight
---
Flammability
Not applicable.
Relative Density
Not determined.
Odor Threshold
Not determined.
Crystallisation Point
---
Vapor Pressure
< 0.1 hPa
Ph
Not applicable.
Boiling Point
Undetermined.
Decomposition Temperature
Not determined.
Lower Explosive Limit
Not determined.
Upper Explosive Limit
Not determined.
Bulk Density
---
Kinematic Viscosity
Not determined.
Explosive Limits
---
Flash Point
> 280 °C
Solubility
---
Metal Corrosion
---
Physical State
Fluid
Cloud Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal storage and use conditions.

Reactivity

No reactivity hazards known under normal storage and use conditions.

Hazardous reactions

No dangerous reactions known.

Avoid

To avoid thermal decomposition do not overheat.

Incompatible

Strong oxidising agents.

Decomposition

Carbon monoxide and partially combusted carbohydrates can be released during thermal decomposition. Fluoride compounds can be released from 400°C.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Waste should not be disposed of by release to sewers. Final decisions on the appropriate waste management method, in line with regional, national and European legislation, and possible adaptation to local conditions, remains the responsibility of the waste treatment operator.

Waste Codes

20 01 26* oil and fat other than those mentioned in 20 01 25 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Interflon Food Grease 000?

The signal word is no signal word.

What is the physical form of Interflon Food Grease 000?

Interflon Food Grease 000 is a fluid with white color. It has odourless odor.

What is Interflon Food Grease 000 used for?

Lubricant

What is the melting point of Interflon Food Grease 000?

The melting point is Not applicable. and the boiling point is Undetermined..