NextSDS Logo
Safety Data Sheet EN

Itzu ISO Vloerreiniger

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Itzu ISO Vloerreiniger
Product Form
Mixture
Product Code
UAC 11921

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Professional use, Cleaning/washing agents and additives

Uses advised against

No additional information available

Manufacturers & Suppliers

ITZU CLEANING logo

ITZU CLEANING

national supplier

Snoekweyerstraat 1, 3600 Genk, België

+32 89 86 98 86

http://www.itzucleaning.eu

Emergency Contacts

Emergency Contact

+32 70 245 245

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
Skin corrosion/irritation Cat. 1 H314

GHS Pictograms

GHS02 - Flammable

GHS02

GHS05 - Corrosive

GHS05

Hazard Statements

H226 Flammable liquid and vapour.
H314 Causes severe skin burns and eye damage.

Precautionary Statements

P210 Keep away from hot surfaces, open flames, sparks, heat. No smoking.
P280 Wear protective clothing/eye protection/face protection, protective gloves.
P301+P330+P331 IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P303+P361+P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water or shower.
P304+P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P363 Wash contaminated clothing before reuse.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Sulphonic acids, C14-17-sec-alkane, sodium salts EC: 307-055-2 97489-15-1 0.1 - 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air and keep comfortable for breathing.

Skin contact

Rinse skin with water/shower. Take off immediately all contaminated clothing. If skin irritation occurs: Get medical advice/attention.

Symptoms: Burns.

Eye contact

Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.

Symptoms: Serious damage to eyes.

Ingestion

Rinse mouth. Do not induce vomiting. Call a poison center or a doctor if you feel unwell.

Symptoms: Burns.

Immediate Medical Attention

If skin irritation occurs: Get medical advice/attention. If eye irritation persists: Get medical advice/attention. Call a poison center or a doctor if you feel unwell. Treat symptomatically.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure good ventilation of the work station.

Hands

Protective gloves

Eyes

Safety glasses

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment

Skin/Body

Wear suitable protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Partition Coefficient
No data available
Boiling Point
No data available
Upper Explosive Limit
---
Dynamic Viscosity
No data available
Bulk Density
---
Flash Point
No data available
Molecular Weight
---
Properties Status
---
Solubility In Water
---
Relative Density
No data available
Kinematic Viscosity
No data available
Solubility In Fat
---
Form
---
Crystallisation Point
---
Flammability
Not applicable
Colour
No data available
Density
---
State Under Standard Conditions
---
Colour Intensity
---
Auto Ignition Temperature
No data available
Softening Point
---
Appearance
---
Physical State Data
liquid
Ph
12,5
Melting Point
Not applicable
Decomposition Temperature
No data available
Voc Content
---
Vapor Pressure
No data available
Metal Corrosion
---
Odor Threshold
No data available
Cloud Point
---
Physical State
Liquid
Lower Explosive Limit
---
Vapor Density
---
Freezing Point
No data available
Solubility
No data available
Evaporation Rate
---
Solidification Point
---
Relative Evaporation Rate
No data available
Odor
No data available
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1993
Shipping Name
FLAMMABLE LIQUID, N.O.S. (mixture with 1-methoxypropan-2-ol)
Transport Class
3
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Itzu ISO Vloerreiniger?

The signal word is danger.

What is the physical form of Itzu ISO Vloerreiniger?

Itzu ISO Vloerreiniger is a liquid with no data available color. It has no data available odor.

What is the solubility of Itzu ISO Vloerreiniger?

No data available

What is Itzu ISO Vloerreiniger used for?

Professional use, Cleaning/washing agents and additives

What are the hazard statements for Itzu ISO Vloerreiniger?

This substance has 2 hazard statements:

  • H226: Flammable liquid and vapour.
  • H314: Causes severe skin burns and eye damage.

What is the melting point of Itzu ISO Vloerreiniger?

The melting point is Not applicable and the boiling point is No data available.