NextSDS Logo
DO

DORMER Schneidl M200 Nr.1

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DORMER Schneidl M200 Nr.1

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Lubricant and lubricant additive Lubricants, greases, release products ( cooling grease ) . (cooling grease)

Overview

DORMER Schneidl M200 Nr.1 is a liquid substance commonly used lubricant and lubricant additive lubricants, greases, release products ( cooling grease ) . (cooling grease).

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Wunsch le GmbH

undefined

๐Ÿ“

Am Sportplatz 7 40882 Ratingen

๐ŸŒ

DE

๐Ÿ“ 

+49 21 02 49 00 10

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 21 02 49 00 00

๐ŸŒ

DE

๐Ÿ•’

24h

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Base oil with additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Distillates (petroleum), solvent-dewaxed light paraffinic
EC: 265-159-2
64742-56-9 25-50% โš ๏ธ Hazardous
Di-tert-dodecyl polysulfide
EC: 270-335-7
68425-15-0 1-10% โš ๏ธ Hazardous
Zinc-bis[0,0-bis(2-ethylhexyl)]bis(dithiophosphate)
EC: 224-235-5
4259-15-8 1-10% โš ๏ธ Hazardous
Benzenesulfonic acid,C10-16-alkyl derivs.,calcium salts
EC: 271-529-4
68584-23-6 1% โš ๏ธ Hazardous
Sulfonic acids, Petroleum, Calcium Salts, Oil soluble
EC: 263-093-9
61789-86-4 0.1-1% โš ๏ธ Hazardous
Benzenesulfonic acid, mono-C16-24-alkyl derivs,calcium salts
EC: 274-263-7
70024-69-0 0.1-1% โš ๏ธ Hazardous

Additional Information

Full text of H- and EUH-phrases: see section 16. Highly refined mineral oil (IP 346 DMSO extract < 3%).

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Provide fresh air. When in doubt or if symptoms are observed, get medical advice.

Symptoms:

Respiratory complaints, Headache, Dizziness, Nausea

๐Ÿ–๏ธ Skin Contact

Wash immediately with: Water and soap .

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses, if present and easy to do. Continue rinsing. Wash with plenty of water. Call a physician immediately.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do NOT induce vomiting. Observe risk of aspiration if vomiting occurs. Call a physician immediately.

Symptoms:

Respiratory complaints, Headache, Dizziness, Nausea

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid
๐ŸŽจ Colour
blue
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
characteristic
๐Ÿ“Š Odor Threshold
not determined
๐Ÿงช Ph
( 23 C / 50 g/l ) not applicable DIN 51 369
๐ŸงŠ Melting Point
not applicable Literature value
Critical Property
๐Ÿ’จ Boiling Point
Not available
๐Ÿ”ฅ Flash Point
175 C
Critical Property
๐Ÿ“Š Freezing Point
< -30 C
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
not determined
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
( 20 C ) not determined
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
( 20 C ) 0,93 g/cm [3] DIN 51757
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
not determined
๐Ÿ“Š Lower Explosive Limit
not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
not determined
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
not determined
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
( 40 C ) 28 mm [2] /s DIN 51562
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

See protective measures under point 7 and 8.

๐Ÿงค Hand Protection

Tested protective gloves must be worn Breakthrough time (maximum wearing time) : 4 hours ( NBR (Nitrile rubber), Thickness of the glove material : 0,4 mm ) . See information supplied by the manufacturer.

๐Ÿ‘๏ธ Eye Protection

Wear eye/face protection.

๐Ÿ˜ท Respiratory Protection

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn. Fresh air masks are recommended, or combination filters A2-P2 for works of short duration.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DORMER Schneidl M200 Nr.1?

The signal word for this substance is "no signal word".

What is the physical form of DORMER Schneidl M200 Nr.1?

DORMER Schneidl M200 Nr.1 is a liquid appearing as liquid with blue color. It has characteristic odor.

What is DORMER Schneidl M200 Nr.1 used for?

Lubricant and lubricant additive Lubricants, greases, release products ( cooling grease ) . (cooling grease)

What are the hazard statements for DORMER Schneidl M200 Nr.1?

This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.

What is the melting point of DORMER Schneidl M200 Nr.1?

The melting point is not applicable Literature value .