NextSDS Logo
Aq

Aquagent, standard solution 0,1%

WARNING Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aquagent, standard solution 0,1%
Product Code
AQ0019

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
VPC0-R05P-K000-S2R8

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Laboratory reagent

Overview

Aquagent, standard solution 0,1% is a fluid substance commonly used laboratory reagent.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour.

Precautionary Statements

  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P241: Use explosion-proof [electrical/ventilating/lighting] equipment.
  • P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
  • P370+P378: In case of fire: Use CO2, powder or water spray to extinguish.
  • P403+P235: Store in a well-ventilated place. Keep cool.
  • P501: Dispose of contents/container in accordance with local/regional/national/ international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Scharlab, S.L. company logo - Safety Data Sheet supplier organization

Scharlab, S.L.

manufacturer

๐Ÿ“

C/Gato Prez, 33. Pol.Ind. Mas d'en Cisa 08181 Sentmenat (Barcelona) SPAIN

๐ŸŒ

ES

๐Ÿ“ž

(+34) 93 745 64 00

๐Ÿ“ 

(+34) 93 715 27 65

๐ŸŒ www.scharlab.com
Scharlab, S.L. company logo - Safety Data Sheet supplier organization

Scharlab, S.L.

regional supplier

๐Ÿ“

C/Gato Prez, 33. Pol.Ind. Mas d'en Cisa 08181 Sentmenat (Barcelona) SPAIN

๐ŸŒ

ES

๐Ÿ“ž

(+34) 93 745 64 00

๐Ÿ“ 

(+34) 93 715 27 65

๐ŸŒ www.scharlab.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Toxicological Information National Institute of Toxicology and Forensic Sciences

๐Ÿ“ž

+ 34 91 562 04 20

๐ŸŒ

ES

๐Ÿ•’

24h/365 days

Scharlab, S.L.

๐Ÿ“ž

(+34) 93 715 18 11

๐ŸŒ

ES

๐Ÿ•’

During normal opening times

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Mixture of substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
anisole
EC: 202-876-1
100-66-3 50-100% โš ๏ธ Hazardous
propylene carbonate
EC: 203-572-1
108-32-7 2-5% โš ๏ธ Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

๐Ÿฝ๏ธ Ingestion/Swallowing

If symptoms persist consult doctor.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Fluid
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
-37 C
Critical Property
๐Ÿ’จ Boiling Point
Undetermined.
Critical Property
๐Ÿ”ฅ Flash Point
43 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
0.4 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.0245 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Flammable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
475 C
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
34 g/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
108.14 g/mol
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Void
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see section 7.

๐Ÿงค Hand Protection

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles

๐Ÿ˜ท Respiratory Protection

Not required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN2222

๐Ÿ“ฆ Proper Shipping Name

ANISOLE

โš ๏ธ Transport Hazard Class

3 Flammable liquids.

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Warning: Flammable liquids.

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Flammable liquids.

โœˆ๏ธ IATA Air Transport Precautions

Warning: Flammable liquids.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aquagent, standard solution 0,1%?

The signal word for this substance is "warning".

What is the physical form of Aquagent, standard solution 0,1%?

Aquagent, standard solution 0,1% is a fluid appearing as fluid with colourless color. It has characteristic odor.

What is Aquagent, standard solution 0,1% used for?

Laboratory reagent

What are the hazard statements for Aquagent, standard solution 0,1%?

This substance has 1 hazard statements: H226: Flammable liquid and vapour.

What is the melting point of Aquagent, standard solution 0,1%?

The melting point is -37 C and the boiling point is Undetermined..