Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Arsenicum standard solution 1000 µg/ml (Plasma HIQU)
- Product Code
- CL01.0133
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
CHEM-LAB NV
manufacturer
Industriezone "De Arend" 2, B-8210 Zedelgem, BELGIUM
+32 50 28 83 20
Emergency Contacts
Emergency Contact
00 (32) 50.28.83.20
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air.
Wash off with plenty of water. Remove contaminated clothing.
Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. Immediately call an ophthalmologist.
Never give anything by mouth to an unconscious person. Make the victim drink plenty of water, induce vomiting. Call in physician.
Immediate Medical Attention
Immediately call an ophthalmologist. Call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
In adaptation to materials stored in the immediate neighbourhood.
Contain escaping vapours with water. Prevent fire-fighting water from entering surface water or groundwater.
Non-combustible. Ambient fire may liberate hazardous vapours.
Do not stay in dangerous zone without self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Firefighter Protection
Do not stay in dangerous zone without self-contained breathing apparatus. In order to avoid contact with skin, keep a safety distance and wear suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not inhale vapours/aerosols. Avoid substance contact. Ensure supply of fresh air in enclosed rooms.
Do not allow to enter sewerage system.
Absorb on vermiculite, sand or a pillow from Chemical Spill Center.
Materials: vermiculite, sand or a pillow from Chemical Spill Center
Related Products
Similar products with comparable safety profiles
Antimony standard solution 1000 µg/ml (Plasma HIQU)
---
Iron standard solution 1000 µg/ml (Plasma HIQU)
---
Copper standard solution 1000 µg/ml (Plasma HIQU)
---
Selenium standard solution 1000 µg/ml (Plasma HIQU)
---
Zinc standard solution 1000 µg/ml (Plasma HIQU)
---
Sodium standard solution 1000 µg/ml (Plasma HIQU)
---
Chromium standard solution 1000 µg/ml (Plasma HIQU)
---
Cobalt standard solution 1000 µg/ml (Plasma HIQU)
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
No special measures necessary. The product should be handled with the care usual when dealing with chemicals. For precautions see section 2.2
Closed in a well ventilated place. Recommended storage temperature see product label.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Work under hood. Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1
Required.
Required.
Required when vapours/aerosols are generated. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Required.
Do not allow to enter sewerage system.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
See section 10.3
Dangerous reactions are not expected handling the product according to its intended use.
No further relevant information available.
No further relevant information available.
No further relevant information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxity
12.2 Persistence and degradability
No further relevant information available.
12.3 Bioaccumulative potential
No further relevant information available.
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
No further relevant information available.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemicals must be disposed of in compliance with the respective national regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3264
- Shipping Name
- Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)
- Transport Class
- 8
- Packing Group
- III
no
no
See Transport (IMDG)
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Arsenicum standard solution 1000 µg/ml (Plasma HIQU)?
The signal word is danger.
What is the physical form of Arsenicum standard solution 1000 µg/ml (Plasma HIQU)?
Arsenicum standard solution 1000 µg/ml (Plasma HIQU) is a liquid with colourless color. It has odourless odor.
What is Arsenicum standard solution 1000 µg/ml (Plasma HIQU) used for?
Reagent for analysis
What are the hazard statements for Arsenicum standard solution 1000 µg/ml (Plasma HIQU)?
This substance has 5 hazard statements:
- H290: May be corrosive to metals.
- H302: Harmful if swallowed.
- H314: Causes severe skin burns and eye damage.
- H350: May cause cancer.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Arsenicum standard solution 1000 µg/ml (Plasma HIQU)?
The melting point is -3°C and the boiling point is 101°C.