NextSDS Logo
Ar

Arsenicum standard solution 1000 g/ml (Plasma HIQU)

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Arsenicum standard solution 1000 g/ml (Plasma HIQU)
Product Code
CL01.0133

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagent for analysis

Overview

Arsenicum standard solution 1000 g/ml (Plasma HIQU) commonly used reagent for analysis.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger :)

Hazard Classifications

Met. Corr. Category 1 H290
Acute Tox. Category 4 H302
Skin Corr. Category 1B H314
Carc. H350
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H290: May be corrosive to metals.
  • H302: Harmful if swallowed.
  • H314: Causes severe skin burns and eye damage.
  • H350: May cause cancer.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P280: Wear protective gloves, protective clothing, eye protection, face protection.
  • IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P310: Immediately call a POISON CENTER or doctor/physician.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CHEM-LAB NV

manufacturer

๐Ÿ“

Industriezone De Arend 2 B-8210 ZEDELGEM - BELGIUM

๐ŸŒ

BE

๐Ÿ“ž

+32 50 28 83 20

๐Ÿ“ 

+32 50 78 26 54

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

00 (32) 50.28.83.20

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Nitric acid 67 - 69% (Pico-Pure) 7697-37-2 2-5% โš ๏ธ Hazardous
Arsenicum(III) oxide a.r. 1327-53-3 0.1-0.2% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Fresh air.

๐Ÿ–๏ธ Skin Contact

Wash off with plenty of water. Remove contaminated clothing.

๐Ÿ‘๏ธ Eye Contact

Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. lmmediately call an ophtalmologist.

๐Ÿฝ๏ธ Ingestion/Swallowing

Never give anything by mouth to an unconscious person. Make the victim drink plenty of water, induce vomiting. Call in physician.

๐Ÿšจ Immediate Medical Attention Required

No data available

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
pH < 1
๐ŸงŠ Melting Point
-3C
Critical Property
๐Ÿ’จ Boiling Point
101C
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,02 g/ml
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Protective clothing should be selected specificlly for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier. See section 7.1

๐Ÿงค Hand Protection

Required.

๐Ÿ‘๏ธ Eye Protection

Required.

๐Ÿ˜ท Respiratory Protection

Required when vapours/aerosols are generated. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.

๐Ÿฆบ Skin/Body Protection

Required.

๐ŸŒ Environmental Exposure Controls

Do not allow to enter sewerage system.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 3264

๐Ÿ“ฆ Proper Shipping Name

Corrosive liquid, acidic, inorganic, n.o.s. (Nitric acid solution)

โš ๏ธ Transport Hazard Class

8

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

no

๐Ÿšข IMDG Maritime Transport Precautions

no

โœˆ๏ธ IATA Air Transport Precautions

no

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Arsenicum standard solution 1000 g/ml (Plasma HIQU)?

The signal word for this substance is "danger".

What is the physical form of Arsenicum standard solution 1000 g/ml (Plasma HIQU)?

Arsenicum standard solution 1000 g/ml (Plasma HIQU) is a liquid with colourless color. It has odourless odor.

What is Arsenicum standard solution 1000 g/ml (Plasma HIQU) used for?

Reagent for analysis

What are the hazard statements for Arsenicum standard solution 1000 g/ml (Plasma HIQU)?

This substance has 5 hazard statements: H290: May be corrosive to metals. H302: Harmful if swallowed. H314: Causes severe skin burns and eye damage. H350: May cause cancer. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Arsenicum standard solution 1000 g/ml (Plasma HIQU)?

The melting point is -3C and the boiling point is 101C.