NextSDS Logo
Sc

Schnellreiniger

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Schnellreiniger

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Cleaner
Uses Advised Against
No information available at present.

Overview

Schnellreiniger commonly used cleaner.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Skin Irr. Category 2 H315
Asp. Tox. Category 1 H304
STOT SE Category 3 H336
Aquatic Chronic Category 2 H411

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS09 GHS Hazard Pictogram: Environmental hazard - Materials toxic to aquatic life and environment

GHS09

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H304: May be fatal if swallowed and enters airways.
  • H336: May cause drowsiness or dizziness.
  • H411: Toxic to aquatic life with long lasting effects.

Precautionary Statements

  • P101: If medical advice is needed, have product container or label at hand.
  • P102: Keep out of reach of children.
  • P210: Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • P243: Take action to prevent static discharges.
  • P261: Avoid breathing vapours or spray.
  • P273: Avoid release to the environment.
  • P280: Wear protective gloves / protective clothing.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER / doctor.
  • P312: Call a POISON CENTRE / doctor if you feel unwell.
  • P331: Do NOT induce vomiting.
  • P403+P233: Store in a well-ventilated place. Keep container tightly closed.
  • P405: Store locked up.
  • P501: Dispose of contents / container to an approved waste disposal facility.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

LIQUI MOLY GmbH

undefined

๐Ÿ“

Jerg-Wieland-Str. 4 89081 Ulm-Lehr

๐ŸŒ

DE

๐Ÿ“ž

(+49) 0731-1420-0

๐Ÿ“ 

(+49) 0731-1420-88

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

LMR

๐Ÿ“ž

+49 (0) 700 / 24 112 112

๐ŸŒ

DE

LMR

๐Ÿ“ž

+1 872 5888271

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbons, C6-C7, n-alkanes, isoalkanes, cyclics, <5% n-hexane
EC: 921-024-6
N/A Not specified โš ๏ธ Hazardous

Composition Notes

For the text of the H-phrases and classification codes (GHS/CLP), see Section 16. The substances named in this section are given with their actual, appropriate classification! For substances that are listed in appendix VI, table 3.1 of the regulation (EC) no. 1272/2008 (CLP regulation) this means that all notes that may be given here for the named classification have been taken into account. The addition of the highest concentrations listed here can result in a classification. Only when this classification is listed in Section 2 does it apply. In all other cases the total concentration is below the classification.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person from danger area. Supply person with fresh air and consult doctor according to symptoms. If the person is unconscious, place in a stable side position and consult a doctor.

๐Ÿ–๏ธ Skin Contact

Remove polluted, soaked clothing immediately, wash thoroughly with plenty of water and soap, in case of irritation of the skin (flare), consult a doctor.

Symptoms:

irritation of the skin (flare)

๐Ÿ‘๏ธ Eye Contact

Remove contact lenses. Wash thoroughly for several minutes using copious water. Seek medical help if necessary.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse the mouth thoroughly with water. Do not induce vomiting - give copious water to drink. Consult doctor immediately. In case of vomiting, keep head low so that the stomach content does not reach the lungs.

๐Ÿšจ Immediate Medical Attention Required

Gastric lavage (stomach washing) only under endotracheal intubation. Subsequent observation for pneumonia and pulmonary oedema.

Medical Treatment

Gastric lavage (stomach washing) only under endotracheal intubation.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Substance is non-soluble (in water).
๐ŸงŠ Melting Point
There is no information available on this parameter.
Critical Property
๐Ÿ’จ Boiling Point
60-120 C
Critical Property
๐Ÿ”ฅ Flash Point
-17 C
Critical Property
๐Ÿ“Š Freezing Point
There is no information available on this parameter.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
61 hPa (20C)
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0,675-0,771 g/cm3 (15C)
Critical Property
๐Ÿ”ฅ Flammability
Flammable
๐Ÿ“Š Upper Explosive Limit
8 Vol-%
๐Ÿ“Š Lower Explosive Limit
0,6 Vol-%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
200 C
๐Ÿ“Š Decomposition Temperature
There is no information available on this parameter.
๐Ÿ’ง Solubility
Insoluble
๐Ÿ“Š Partition Coefficient
There is no information available on this parameter.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
0,49 mm2/s (40C)
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure good ventilation. This can be achieved by local suction or general air extraction. If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn. Applies only if maximum permissible exposure values are listed here. Suitable assessment methods for reviewing the effectiveness of protection measures adopted include metrological and non-metrological investigative techniques. These are specified by e.g. EN 14042. EN 14042 "Workplace atmospheres. Guide for the application and use of procedures for the assessment of exposure to chemical and biological agents".

๐Ÿงค Hand Protection

Solvent resistant protective gloves (EN ISO 374). Recommended Protective Viton / fluoroelastomer gloves (EN ISO 374). Minimum layer thickness in mm: >= 0,4. Protective nitrile gloves (EN ISO 374). Minimum layer thickness in mm: >= 0,4. Permeation time (penetration time) in minutes: >= 480. Protective hand cream recommended. The breakthrough times determined in accordance with EN 16523-1 were not obtained under practical conditions. The recommended maximum wearing time is 50% of breakthrough time. Additional information on hand protection - No tests have been performed. In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents. Selection of materials derived from glove manufacturer's indications. Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account. Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to manufacturer. In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use. The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.

๐Ÿ‘๏ธ Eye Protection

Tight fitting protective goggles with side protection (EN 166).

๐Ÿ˜ท Respiratory Protection

If OES or MEL is exceeded. Gas mask filter A (EN 14387), code colour brown. At high concentrations: Respiratory protection appliance (insulation device) (e.g. EN 137 or EN 138). Observe wearing time limitations for respiratory protection equipment.

๐Ÿฆบ Skin/Body Protection

Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments).

๐ŸŒ Environmental Exposure Controls

No information available at present.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3295

๐Ÿ“ฆ Proper Shipping Name

HYDROCARBONS, LIQUID, N.O.S.

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Schnellreiniger?

The signal word for this substance is "danger".

What is the physical form of Schnellreiniger?

Schnellreiniger is a liquid with colourless color. It has characteristic odor.

What is the solubility of Schnellreiniger?

Insoluble

What is Schnellreiniger used for?

Cleaner

What are the hazard statements for Schnellreiniger?

This substance has 5 hazard statements: H225: Highly flammable liquid and vapour. H315: Causes skin irritation. H304: May be fatal if swallowed and enters airways. H336: May cause drowsiness or dizziness. H411: Toxic to aquatic life with long lasting effects.

What is the melting point of Schnellreiniger?

The melting point is There is no information available on this parameter. and the boiling point is 60-120 C.