Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Siliconspray 300 ML
- Product Code
- 3310
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Eluent, Lubricant, SU21 - Consumer uses: Private households (=general public = consumers), SU22 - Professional uses: Public domain (administration, education, entertainment, services, craftsmen), PC24 - Lubricants, greases, release products, PROC11 - Non industrial spraying, ERC 8a - Wide dispersive indoor use of processing aids in open systems, ERC 8d - Wide dispersive outdoor use of processing aids in open systems
Uses advised against
No information available at present.
Manufacturers & Suppliers
LIQUI MOLY GmbH
Jerg-Wieland-Strae 4, D-89081 Ulm-Lehr
Emergency Contacts
LIQUI MOLY GmbH
(+49) 0731-1420-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Aerosol
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C7-C9, n-alkanes, isoalkanes, cyclics EC: 920-750-0 | --- | 2.5 - 10% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person from danger area. Supply person with fresh air and consult doctor according to symptoms. If the person is unconscious, place in a stable side position and consult a doctor. Respiratory arrest - Artificial respiration apparatus necessary.
Symptoms: Irritation of the respiratory tract, Headaches, Dizziness, Effects/damages the central nervous system, Coordination disorders, fatigue, Unconsciousness.
Remove polluted, soaked clothing immediately, wash thoroughly with plenty of water and soap, in case of irritation of the skin (flare), consult a doctor.
Symptoms: Irritation of the skin. Drying of the skin. Dermatitis (skin inflammation).
Remove contact lenses. Wash thoroughly for several minutes using copious water. Seek medical help if necessary. Consult medical specialist.
Symptoms: Irritation of the eyes.
Rinse the mouth thoroughly with water. Immediate admittance to a hospital.
Immediate Medical Attention
Consult doctor according to symptoms. If the person is unconscious, consult a doctor. Respiratory arrest - Artificial respiration apparatus necessary. In case of irritation of the skin (flare), consult a doctor. Seek medical help if necessary. Consult medical specialist. Immediate admittance to a hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation. This can be achieved by local suction or general air extraction. If this is insufficient to maintain the concentration under the WEL or AGW values, suitable breathing protection should be worn. Applies only if maximum permissible exposure values are listed here.
Chemical resistant protective gloves (EN 374). Recommended Protective nitrile gloves (EN 374) Minimum layer thickness in mm: 0,65 Permeation time (penetration time) in minutes: - 120 Protective hand cream recommended. Additional information on hand protection - No tests have been performed. In the case of mixtures, the selection has been made according to the knowledge available and the information about the contents. Selection of materials derived from glove manufacturer's indications. Final selection of glove material must be made taking the breakthrough times, permeation rates and degradation into account. Selection of a suitable glove depends not only on the material but also on other quality characteristics and varies from manufacturer to manufacturer. In the case of mixtures, the resistance of glove materials cannot be predicted and must therefore be tested before use. The exact breakthrough time of the glove material can be requested from the protective glove manufacturer and must be observed.
With danger of contact with eyes. Tight fitting protective goggles with side protection (EN 166).
Normally not necessary. In case of emergency: Respiratory protection appliance (insulation device) (e.g. EN 137 or EN 138)
Protective working garments (e.g. safety shoes EN ISO 20345, long-sleeved protective working garments)
No information available at present.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
Persons employed in transporting dangerous goods must be trained. All persons involved in transporting must observe safety regulations. Precautions must be taken to prevent damage.
Persons employed in transporting dangerous goods must be trained. All persons involved in transporting must observe safety regulations. Precautions must be taken to prevent damage.
Persons employed in transporting dangerous goods must be trained. All persons involved in transporting must observe safety regulations. Precautions must be taken to prevent damage.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Siliconspray 300 ML?
The signal word is danger.
What is the physical form of Siliconspray 300 ML?
Siliconspray 300 ML is a aerosol, substance: liquid with colourless color. It has characteristic odor.
What is the solubility of Siliconspray 300 ML?
Alcohols, Hydrocarbons
What is Siliconspray 300 ML used for?
Eluent, Lubricant, SU21 - Consumer uses: Private households (=general public = consumers), SU22 - Professional uses: Public domain (administration, education, entertainment, services, craftsmen), PC24 - Lubricants, greases, release products, PROC11 - Non industrial spraying, ERC 8a - Wide dispersive indoor use of processing aids in open systems, ERC 8d - Wide dispersive outdoor use of processing aids in open systems
What are the hazard statements for Siliconspray 300 ML?
This substance has 3 hazard statements:
- H222: Extremely flammable aerosol.
- H229: Pressurised container: May burst if heated.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Siliconspray 300 ML?
The melting point is Not determined and the boiling point is Not determined.