NextSDS Logo
EO

EOSIN-RAL 555

WARNING Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
EOSIN-RAL 555

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
In vitro diagnostic medical device. For professional use only.

Overview

EOSIN-RAL 555 commonly used in vitro diagnostic medical device. for professional use only..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • If skin irritation or rash occurs: Get medical advice/attention

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

RAL DIAGNOSTICS S.A.S. company logo - Safety Data Sheet supplier organization

RAL DIAGNOSTICS S.A.S.

global supplier

๐Ÿ“

Site Montesquieu 33651 MARTILLAC CEDEX France

๐ŸŒ

FR

๐Ÿ“ž

+33 (0) 5 57 96 04 04

๐Ÿ“ 

+33 (0) 5 57 96 04 05

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

ORFILA

๐Ÿ“ž

+33 (0) 1 45 42 59 59

๐ŸŒ

FR

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Preparation

General Composition

This product is considered to be hazardous and contains hazardous components.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Eosin Y
EC: 241-409-6
17372-87-1 0.1% โš ๏ธ Hazardous
A mixture of: 5-chloro-2-methyl-2H- isothiazol-3-one [EC No 247-500-7] and 2-methyl-2H-isothiazol-3-one [EC No 220-239-6] (3:1) 55965-84-9 0.005% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Take victim to fresh air. Obtain medical attention if breathing difficulty persists.

Symptoms:

Breathing difficulty (if it persists). Not expected to present a significant inhalation hazard under anticipated conditions of normal use.

๐Ÿ–๏ธ Skin Contact

Flush with plenty of water. Seek medical attention if ill effect or irritation develops.

Symptoms:

Ill effect or irritation (if it develops). May cause sensitization by skin contact.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of water. Seek medical attention if irritation develops.

Symptoms:

Irritation (if it develops). Not expected to present a significant eye contact hazard under anticipated conditions of normal use.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse mouth. Seek medical attention if ill effect develops.

Symptoms:

Ill effect (if it develops). No significant signs or symptoms indicative of any adverse health hazard are expected to occur as a result of ingestion.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Orangey red.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Odourless.
๐Ÿ“Š Odor Threshold
No data available.
๐Ÿงช Ph
6.9 7.1
๐ŸงŠ Melting Point
No data available.
Critical Property
๐Ÿ’จ Boiling Point
No data available.
Critical Property
๐Ÿ”ฅ Flash Point
No data available.
Critical Property
๐Ÿ“Š Freezing Point
No data available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No data available.
๐Ÿ’จ Vapor Pressure
No data available.
๐Ÿ“Š Vapor Density
No data available.
๐Ÿ“Š Relative Density
1.00-1.02
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.00-1.02
Critical Property
๐Ÿ”ฅ Flammability
No data available.
๐Ÿ“Š Upper Explosive Limit
No data available.
๐Ÿ“Š Lower Explosive Limit
No data available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
No data available.
๐Ÿ“Š Decomposition Temperature
No data available.
๐Ÿ’ง Solubility
No data available.
๐Ÿ“Š Partition Coefficient
No data available.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
No data available.
๐Ÿ“Š Kinematic Viscosity
No data available.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide good ventilation in process area to prevent formation of vapour.

๐Ÿงค Hand Protection

Gloves. The selected protective gloves have to satisfy the specifications of EU Directive 89/ 686/EEC and the standard EN 374 derived from it. In full: Material: nitrile rubber. Minimum thickness: 0.10 mm. Break through time: Not tested. Proposed equipment : Touch N Tuff (Ansell 92-500 ou 92-670). In the event of splashes: Material: nitrile rubber. Minimum thickness: 0.10 mm. Break through time: Not tested. Proposed equipment : Touch N Tuff (Ansell 92-500 ou 92-670). Source of data: Ansell Healthcare Europe N.V., Riverside Business Park, Block J, Boulevard International 55, B-1070 Brussels, Belgium, Tel. +32 (0)2 528 74 00, e-mail : [email protected].

๐Ÿ‘๏ธ Eye Protection

Safety glasses. Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

๐Ÿ˜ท Respiratory Protection

Not required.

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing. Choose body protection in relation to the dangerousness of the product, its concentration and the amounts used depending on the workstation.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

Unregulated.

๐Ÿ“ฆ Proper Shipping Name

Unregulated.

โš ๏ธ Transport Hazard Class

Unregulated.

๐Ÿ“‹ Packing Group

Unregulated.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for EOSIN-RAL 555?

The signal word for this substance is "warning".

What is the physical form of EOSIN-RAL 555?

EOSIN-RAL 555 is a liquid. with orangey red. color. It has odourless. odor.

What is the solubility of EOSIN-RAL 555?

No data available.

What is EOSIN-RAL 555 used for?

In vitro diagnostic medical device. For professional use only.

What are the hazard statements for EOSIN-RAL 555?

This substance has 1 hazard statements: H317: May cause an allergic skin reaction.

What is the melting point of EOSIN-RAL 555?

The melting point is No data available. and the boiling point is No data available..