3M Attest 1292E Rapid Readout Biological Indicator
Product Code
70-2007-2241-4

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
To indicate attainment of conditions for sterilization.

Overview

3M Attest 1292E Rapid Readout Biological Indicator is a glass ampule with test strip and media, enclosed in a covered plastic vial. substance commonly used to indicate attainment of conditions for sterilization..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (Not applicable.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

3M

manufacturer

๐Ÿ“

3M Center, St. Paul, MN 55144-1000, USA

๐ŸŒ

US

๐Ÿ“ž

1-888-3M HELPS (1-888-364-3577)

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

1-800-364-3577

๐ŸŒ

US

๐Ÿ•’

24 hours

Emergency Contact

๐Ÿ“ž

(651) 737-6501

๐ŸŒ

US

๐Ÿ•’

24 hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Growth media containing carbohydrates, peptone, amino acides, dye N/A 95-100% โœ“ Non-hazardous
Thinsulate N/A 2-5% โœ“ Non-hazardous
Spore strip Geobacillus stearothermophilus (previously Bacillus stearothermophilus) N/A 1% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

No need for first aid is anticipated.

๐Ÿ–๏ธ Skin Contact

No need for first aid is anticipated.

๐Ÿ‘๏ธ Eye Contact

No need for first aid is anticipated.

๐Ÿฝ๏ธ Ingestion/Swallowing

No need for first aid is anticipated.

๐Ÿšจ Immediate Medical Attention Required

Not applicable

Medical Treatment

Not applicable

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Glass ampule with test strip and media, enclosed in a covered plastic vial.
๐ŸŽจ Colour
Glass ampule with test strip and media, enclosed in a covered plastic vial.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Glass ampule with test strip and media, enclosed in a covered plastic vial.
๐Ÿ‘ƒ Odor
Glass ampule with test strip and media, enclosed in a covered plastic vial.
๐Ÿ“Š Odor Threshold
Not Applicable
๐Ÿงช Ph
Approximately 7.5 [Details: (applies to media)]
๐ŸงŠ Melting Point
No Data Available
Critical Property
๐Ÿ’จ Boiling Point
Approximately 100 C [Details: (applies to media)]
Critical Property
๐Ÿ”ฅ Flash Point
Not Applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
No Data Available
๐Ÿ’จ Vapor Pressure
No Data Available
๐Ÿ“Š Vapor Density
No Data Available
๐Ÿ“Š Relative Density
Approximately 1 [Ref Std: WATER=1]
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1 g/ml
Critical Property
๐Ÿ”ฅ Flammability
Not Applicable
๐Ÿ“Š Upper Explosive Limit
Not Applicable
๐Ÿ“Š Lower Explosive Limit
Not Applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not Applicable
๐Ÿ“Š Decomposition Temperature
Not Applicable
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not Applicable
๐Ÿ“Š Solubility In Water
Negligible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Approximately 0 g/l
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 3M Attest 1292E Rapid Readout Biological Indicator?

The signal word for this substance is "no signal word".

What is the physical form of 3M Attest 1292E Rapid Readout Biological Indicator?

3M Attest 1292E Rapid Readout Biological Indicator is a liquid appearing as glass ampule with test strip and media, enclosed in a covered plastic vial. with glass ampule with test strip and media, enclosed in a covered plastic vial. color. It has glass ampule with test strip and media, enclosed in a covered plastic vial. odor.

What is 3M Attest 1292E Rapid Readout Biological Indicator used for?

To indicate attainment of conditions for sterilization.

What is the melting point of 3M Attest 1292E Rapid Readout Biological Indicator?

The melting point is No Data Available and the boiling point is Approximately 100 C [Details: (applies to media)].