NextSDS Logo
Sh

Shell Tonna S3 M 68

NO SIGNAL WORD Liquid at room temperature. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Shell Tonna S3 M 68
Product Code
001D7774

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Machine oil.

Overview

Shell Tonna S3 M 68 is a liquid at room temperature. substance commonly used machine oil..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (No signal word)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Viva Energy Australia Pty Ltd

national supplier

๐Ÿ“

720 Bourke Street Docklands Victoria 3008 Australia

๐ŸŒ

AU

๐Ÿ“ž

+61 (0)3 8823 4444

๐Ÿ“ 

+61 (0)3 8823 4800

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

1800 651 818

๐ŸŒ

AU

POISONS INFORMATION CENTRE

๐Ÿ“ž

13 11 26

๐ŸŒ

AU

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Highly refined mineral oils and additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Interchangeable low viscosity base oil (<20,5 cSt @40C) Not Assigned 90% โš ๏ธ Hazardous
Alkyl thiadiazole 13539-13-4 Not specified โš ๏ธ Hazardous

Additional Information

contains one or more of the following CAS-numbers: 6474253-6, 64742-54-7, 64742-55-8, 64742-56-9, 64742-65-0, 68037-01-4, 72623-86-0, 72623-87-1, 8042-47-5, 848301-699.

Composition Notes

The highly refined mineral oil contains <3% (w/w) DMSOextract, according to IP346.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

No treatment necessary under normal conditions of use.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available.

๐Ÿ‘๏ธ Eye Contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing.

๐Ÿฝ๏ธ Ingestion/Swallowing

In general no treatment is necessary unless large quantities are swallowed.

Symptoms:

Ingestion may result in nausea, vomiting and/or diarrhoea.

๐Ÿšจ Immediate Medical Attention Required

If symptoms persist, obtain medical advice. If persistent irritation occurs, obtain medical attention. If large quantities are swallowed, get medical advice.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid at room temperature.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Liquid at room temperature.
๐Ÿ‘๏ธ Appearance
Liquid at room temperature.
๐ŸŽจ Colour
light brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Slight hydrocarbon
๐Ÿ“Š Odor Threshold
Data not available
๐Ÿงช Ph
Not applicable
๐ŸงŠ Melting Point
Data not available
Critical Property
๐Ÿ’จ Boiling Point
> 280 C / 536 Festimated value(s)
Critical Property
๐Ÿ”ฅ Flash Point
225 C / 437 F Method: ISO 2592
Critical Property
๐Ÿ“Š Freezing Point
Data not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Data not available
๐Ÿ’จ Vapor Pressure
< 0.5 Pa (20 C / 68 F) estimated value(s)
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
0.879 (15 C / 59 F)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
879 kg/m3 (15.0 C / 59.0 F) Method: ISO 12185
Critical Property
๐Ÿ”ฅ Flammability
Data not available
๐Ÿ“Š Upper Explosive Limit
Typical 10 %(V)
๐Ÿ“Š Lower Explosive Limit
Typical 1 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
> 320 C / 608 F
๐Ÿ“Š Decomposition Temperature
Data not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
log Pow: > 6(based on information on similar products)
๐Ÿ“Š Solubility In Water
negligible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Data not available
๐Ÿ“Š Kinematic Viscosity
68 mm2/s (40.0 C / 104.0 F) Method: ISO 3104 8.6 mm2/s (100 C / 212 F) Method: ISO 3104
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated.

๐Ÿงค Hand Protection

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.

๐Ÿ‘๏ธ Eye Protection

If material is handled such that it could be splashed into eyes, protective eyewear is recommended.

๐Ÿ˜ท Respiratory Protection

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for the combination of organic gases and vapours and particles [Type A/Type P boiling point >65C (149F)].

๐Ÿฆบ Skin/Body Protection

Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.

๐ŸŒ Environmental Exposure Controls

Take appropriate measures to fulfill the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Section 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Shell Tonna S3 M 68?

The signal word for this substance is "no signal word".

What is the physical form of Shell Tonna S3 M 68?

Shell Tonna S3 M 68 is a liquid at room temperature. appearing as liquid at room temperature. with light brown color. It has slight hydrocarbon odor.

What is Shell Tonna S3 M 68 used for?

Machine oil.

What is the melting point of Shell Tonna S3 M 68?

The melting point is Data not available and the boiling point is > 280 C / 536 Festimated value(s).