NextSDS Logo
OP

OP-U SUSPENSION

WARNING Liquid. [Suspension] SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
OP-U SUSPENSION
Product Form
Liquid
Product Code
40700002, 40700003

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Polishing agent for materialographic specimen preparation. Professional applications.

Overview

OP-U SUSPENSION commonly used polishing agent for materialographic specimen preparation. professional applications..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.

Precautionary Statements

  • P280: Wear protective gloves.
  • P261: Avoid breathing vapor.
  • P272: Contaminated work clothing must not be allowed out of the workplace.
  • P363: Wash contaminated clothing before reuse.
  • IF ON SKIN: Wash with plenty of water.
  • If skin irritation or rash occurs: Get medical advice or attention.
  • P501: Dispose of contents and container in accordance with all local, regional, national and international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Struers Inc.

global supplier

๐Ÿ“

24766 Detroit Rd. Westlake Cleveland, OH 44145 United States

๐ŸŒ

US

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

National Capital Poison Center

๐Ÿ“ž

1-800-222-1222

๐ŸŒ

US

Infotrac

๐Ÿ“ž

1-800-535-5053

๐ŸŒ

US

Struers US

๐Ÿ“ž

1-440-871-0071

๐ŸŒ

US

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
3(2H)-Isothiazolone, 2-methyl- 2682-20-4 0.1% โš ๏ธ Hazardous

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

No specific data.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms:

Adverse symptoms may include the following: irritation, redness

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Symptoms:

No specific data.

๐Ÿฝ๏ธ Ingestion/Swallowing

Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

No specific data.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention if irritation occurs, if adverse health effects persist or are severe, or if unconscious. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically. No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid. [Suspension]
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
White.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Odor [Slight]
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
9.5
๐ŸงŠ Melting Point
0C (32F)
Critical Property
๐Ÿ’จ Boiling Point
100C (212F)
Critical Property
๐Ÿ”ฅ Flash Point
Not available.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
1.3
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available.
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available.
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Soluble in the following materials: cold water and hot water.
๐Ÿ“Š Partition Coefficient
Not applicable.
๐Ÿ“Š Solubility In Water
Not available
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
100 g/l (calculated)
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

๐Ÿงค Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

๐Ÿ‘๏ธ Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with sideshields.

๐Ÿ˜ท Respiratory Protection

Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: (as filter combination A2/P2)

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for OP-U SUSPENSION?

The signal word for this substance is "warning".

What is the physical form of OP-U SUSPENSION?

OP-U SUSPENSION is a liquid. [suspension] with white. color. It has odor [slight] odor.

What is the solubility of OP-U SUSPENSION?

Soluble in the following materials: cold water and hot water.

What is OP-U SUSPENSION used for?

Polishing agent for materialographic specimen preparation. Professional applications.

What are the hazard statements for OP-U SUSPENSION?

This substance has 1 hazard statements: H317: May cause an allergic skin reaction.

What is the melting point of OP-U SUSPENSION?

The melting point is 0C (32F) and the boiling point is 100C (212F).