NextSDS Logo
CI

CIMENT FONDU

NO SIGNAL WORD Powder or dust. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
CIMENT FONDU

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Hydraulic binder for concretes and dry-mix mortars manufacturing

Overview

CIMENT FONDU commonly used hydraulic binder for concretes and dry-mix mortars manufacturing.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

KERNEOS SA.

global supplier

๐Ÿ“

11 cours Valmy - Immeuble Pacific - CS 20058.92977.Paris La Dfence CEDEX.FRANCE.

๐ŸŒ

FR

๐Ÿ“ž

+33 1 46 37 90 00

๐Ÿ“ 

+33 1 46 37 92 00

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

INRS / ORFILA

๐Ÿ“ž

+33 (0)1 45 42 59 59

๐ŸŒ

FR

๐Ÿ’ก

http://www.centres-antipoison.net

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

CEMENT, ALUMINA, CHEMICALS

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
CEMENT, ALUMINA, CHEMICALS
EC: 266-045-5
65997-16-2 100% โœ“ Non-hazardous

Additional Information

In accordance with the requirements REACH Annex XVII, art. 47 does not contain quantities of hexavalent chromium> 2 ppm, measured according to EN 196-10 Does not contain any detectable quantities of free lime or free crystalline silica (such as quartz, tridymite or cristobalite)

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

In case of exposure to high concentrations of dust : move the affected person away from the contaminated area and into the fresh air

๐Ÿ–๏ธ Skin Contact

Watch out for any remaining product between skin and clothing, watches, shoes, etc. Wash with soap

๐Ÿ‘๏ธ Eye Contact

Wash thoroughly with soft, clean water for 15 minutes holding the eyelids open.

Symptoms:

redness, pain or visual impairment

๐Ÿฝ๏ธ Ingestion/Swallowing

Seek medical attention, showing the label.

๐Ÿšจ Immediate Medical Attention Required

No data available.

Medical Treatment

No data available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Powder or dust.
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Grey / brown
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
11 - 11.5 (20C - 10%)
๐ŸงŠ Melting Point
1300 C.
Critical Property
๐Ÿ’จ Boiling Point
Not relevant.
Critical Property
๐Ÿ”ฅ Flash Point
Not relevant.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not relevant.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
1100 - 1300 kg/m3
โš–๏ธ Density
3.2 - 3.3
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not relevant.
๐Ÿ“Š Decomposition Temperature
Not relevant.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Partially soluble. <2%
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure that there is adequate ventilation, especially in confined areas.

๐Ÿงค Hand Protection

Wear suitable protective gloves in the event of prolonged or repeated skin contact.

๐Ÿ‘๏ธ Eye Protection

Avoid contact with eyes. Before handling powders or dust emission, wear mask goggles in accordance with standard EN166.

๐Ÿ˜ท Respiratory Protection

Avoid breathing dust. Wear a disposable half-mask dust filter in accordance with standard EN149.

๐Ÿฆบ Skin/Body Protection

Work clothing worn by personnel shall be laundered regularly. After contact with the product, all parts of the body that have been soiled must be washed.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for CIMENT FONDU?

The signal word for this substance is "no signal word".

What is the physical form of CIMENT FONDU?

CIMENT FONDU is a powder or dust. with grey / brown color. It has odourless odor.

What is CIMENT FONDU used for?

Hydraulic binder for concretes and dry-mix mortars manufacturing

What is the melting point of CIMENT FONDU?

The melting point is 1300 C. and the boiling point is Not relevant..