NextSDS Logo
Safety Data Sheet EN

CIMENT FONDU®

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
CIMENT FONDU®

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Hydraulic binder for concretes and dry-mix mortars manufacturing

Manufacturers & Suppliers

K

KERNEOS SA.

manufacturer

11 cours Valmy - Immeuble Pacific - CS 20058.92977.Paris La Défence CEDEX.FRANCE.

+33 1 46 37 90 00

Emergency Contacts

INRS / ORFILA

+33 (0)1 45 42 59 59

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

CEMENT, ALUMINA, CHEMICALS

Chemical Name CAS Number Concentration Hazardous
CEMENT, ALUMINA, CHEMICALS EC: 266-045-5 65997-16-2 100% No

In accordance with the requirements REACH Annex XVII, art. 47 does not contain quantities of hexavalent chromium> 2 ppm, measured according to EN 196-10 Does not contain any detectable quantities of free lime or free crystalline silica (such as quartz, tridymite or cristobalite)

Notes

In accordance with the requirements REACH Annex XVII, art. 47 does not contain quantities of hexavalent chromium > 2 ppm, measured according to EN 196-10. Does not contain any detectable quantities of free lime or free crystalline silica (such as quartz, tridymite or cristobalite)

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of exposure to high concentrations of dust : move the affected person away from the contaminated area and into the fresh air

Skin contact

Watch out for any remaining product between skin and clothing, watches, shoes, etc. Wash with soap

Eye contact

Wash thoroughly with soft, clean water for 15 minutes holding the eyelids open.

Symptoms: redness, pain or visual impairment

Ingestion

NEVER induce swallowing by an unconscious person. Seek medical attention, showing the label.

Immediate Medical Attention

As a general rule, in case of doubt or if symptoms persist, always call a doctor. Seek medical attention, showing the label.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Non flammable

Specific hazards

Do not breathe in smoke.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Consult the safety measures listed under headings 7 and 8.

Environmental

Prevent any material from entering drains or waterways.

Cleanup methods

Retrieve the product by mechanical means (sweeping/vacuuming)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always wash hands after handling.

Hygiene

Always wash hands after handling.

Fire prevention

Prevent access by unauthorised personnel.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure that there is adequate ventilation, especially in confined areas.

Hands

Wear suitable protective gloves in the event of prolonged or repeated skin contact.

Eyes

Avoid contact with eyes. Before handling powders or dust emission, wear mask goggles in accordance with standard EN166.

Respiratory

Avoid breathing dust. Wear a disposable half-mask dust filter in accordance with standard EN149.

Skin/Body

Work clothing worn by personnel shall be laundered regularly. After contact with the product, all parts of the body that have been soiled must be washed.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Form
---
Upper Explosive Limit
---
Bulk Density
1100 - 1300 kg/m3
Softening Point
---
Relative Evaporation Rate
---
Freezing Point
---
Physical State
Powder or dust.
Explosive Limits
---
Flammability
---
Flash Point
Not relevant.
Melting Point
1300 °C.
Auto Ignition Temperature
Not relevant.
Colour
Grey / brown
State Under Standard Conditions
---
Odor Threshold
---
Solidification Point
---
Metal Corrosion
---
Appearance
---
Boiling Point
Not relevant.
Solubility In Water
Partially soluble. <2%
Partition Coefficient
---
Vapor Density
---
Kinematic Viscosity
---
Odor
Odourless
Density
3.2 - 3.3
Vapor Pressure
Not relevant.
Colour Intensity
---
Solubility
---
Voc Content
---
Lower Explosive Limit
---
Molecular Weight
---
Decomposition Temperature
Not relevant.
Properties Status
---
Ph
11 - 11.5 (20°C - 10%)
Physical State Data
solid
Solubility In Fat
---
Crystallisation Point
---
Evaporation Rate
---
Relative Density
---
Cloud Point
---
Dynamic Viscosity
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This substance is stable under the recommended handling and storage conditions in section 7.

Reactivity

In the presence of water, calcium aluminates react chemically and harden to form stable calcium aluminate hydrates. This reaction is exo-thermal and may last up to 24 hours. The total heat released is < 500 kJ/kg.

Hazardous reactions

None under normal conditions.

Avoid

formation of dusts, humidity

Incompatible

None, to our knowledge

Decomposition

None, to our knowledge

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company.

Disposal

Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for CIMENT FONDU®?

The signal word is no signal word.

What is the physical form of CIMENT FONDU®?

CIMENT FONDU® is a powder or dust. with grey / brown color. It has odourless odor.

What is CIMENT FONDU® used for?

Hydraulic binder for concretes and dry-mix mortars manufacturing

What is the melting point of CIMENT FONDU®?

The melting point is 1300 °C. and the boiling point is Not relevant..