Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CIMENT FONDU®
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hydraulic binder for concretes and dry-mix mortars manufacturing
Manufacturers & Suppliers
KERNEOS SA.
manufacturer
11 cours Valmy - Immeuble Pacific - CS 20058.92977.Paris La Défence CEDEX.FRANCE.
+33 1 46 37 90 00
Emergency Contacts
INRS / ORFILA
+33 (0)1 45 42 59 59
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
CEMENT, ALUMINA, CHEMICALS
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| CEMENT, ALUMINA, CHEMICALS EC: 266-045-5 | 65997-16-2 | 100% | No |
In accordance with the requirements REACH Annex XVII, art. 47 does not contain quantities of hexavalent chromium> 2 ppm, measured according to EN 196-10 Does not contain any detectable quantities of free lime or free crystalline silica (such as quartz, tridymite or cristobalite)
Notes
In accordance with the requirements REACH Annex XVII, art. 47 does not contain quantities of hexavalent chromium > 2 ppm, measured according to EN 196-10. Does not contain any detectable quantities of free lime or free crystalline silica (such as quartz, tridymite or cristobalite)
First Aid Measures
Emergency procedures for chemical exposure incidents
In case of exposure to high concentrations of dust : move the affected person away from the contaminated area and into the fresh air
Watch out for any remaining product between skin and clothing, watches, shoes, etc. Wash with soap
Wash thoroughly with soft, clean water for 15 minutes holding the eyelids open.
Symptoms: redness, pain or visual impairment
NEVER induce swallowing by an unconscious person. Seek medical attention, showing the label.
Immediate Medical Attention
As a general rule, in case of doubt or if symptoms persist, always call a doctor. Seek medical attention, showing the label.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Non flammable
Do not breathe in smoke.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Consult the safety measures listed under headings 7 and 8.
Prevent any material from entering drains or waterways.
Retrieve the product by mechanical means (sweeping/vacuuming)
Related Products
Similar products with comparable safety profiles
Soudal Firecement HT®
---
CROMOFIX BEIGE 01B358
---
CROMOFIX BEIGE 01B359
---
TIP TOP CEMENT SC 2000
---
Cement
---
Blitzdämmer®, Brunnen-Dämmer®, CableCem®, CemConex®-Mörtel, CEM-Rock®, Dämmer®, Depocrete®, DiWa-mix®, Drill-mix®, Ground-mix, GrowCem®, Hydrolith, HT, Jet-Mix®, MIXXAN®, Owalith, P4, Powercrete®, Procrete®, RBM, Recyclingbinder®, RM-Conline, Seku-mix®, Spezial-Fertigbeton (Zaunmörtel), Stabiflex / Biton, SWM, ThermoCem®, Tübbingmörtel, Ultrafin, WatCem, Zement/Bentonit-Gemisch
UFI: J600-604V-M00V-5JJH, 4800-P0U8-X00C-TW4K, DC00-60HP-700V-G7QN, RF00-Q072-J00C-4K9Q, VH00-60WF-U00U-TWVS, TM00-Q0KV-500C-F8FU, 1Q00-7098-F00U-4M1W, 9S00-Q0YN-S00A-SXMY, DV00-70P2-200U-F971, EY00-R0CF-D00A-3MT3, U110-801U-P00T-SYD5, 5410-R0R8-000A-E9Y7, N910-S041-M00A-R04C, QD10-80TE-W00T-EAQE, 1G10-S0GU-7009-2P9G, DJ10-9067-H00T-R0VJ, 3R10-90K1-400S-2Q1P, TT10-T08E-F009-Q1MR, EW10-90XT-R00S-DD6T, V020-T0N7-2008-1QSV, 0220-A0AM-C00S-Q2CX, A520-U010-P008-CDY0, X820-A0QD-Y00R-1RJ2, XA20-U0DT-9008-P344, FK20-C0G0-600R-P3VA, 1P20-V05D-H007-AFFD, NS20-C0US-T00Q-0T1F, VU20-V0J6-4007-N4MH, AX20-D07K-E00Q-AG6K, 2330-D0MD-100Q-N5CQ, D830-E005-N00P-YUHU
Fine Cement D189A
---
GIOLITTI-CANTONI broth (Base) acc. ISO 6888 GranuCult®
UFI: 4840-V640-799K-8DYA
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always wash hands after handling.
Always wash hands after handling.
Prevent access by unauthorised personnel.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure that there is adequate ventilation, especially in confined areas.
Wear suitable protective gloves in the event of prolonged or repeated skin contact.
Avoid contact with eyes. Before handling powders or dust emission, wear mask goggles in accordance with standard EN166.
Avoid breathing dust. Wear a disposable half-mask dust filter in accordance with standard EN149.
Work clothing worn by personnel shall be laundered regularly. After contact with the product, all parts of the body that have been soiled must be washed.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
This substance is stable under the recommended handling and storage conditions in section 7.
In the presence of water, calcium aluminates react chemically and harden to form stable calcium aluminate hydrates. This reaction is exo-thermal and may last up to 24 hours. The total heat released is < 500 kJ/kg.
None under normal conditions.
formation of dusts, humidity
None, to our knowledge
None, to our knowledge
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company.
Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CIMENT FONDU®?
The signal word is no signal word.
What is the physical form of CIMENT FONDU®?
CIMENT FONDU® is a powder or dust. with grey / brown color. It has odourless odor.
What is CIMENT FONDU® used for?
Hydraulic binder for concretes and dry-mix mortars manufacturing
What is the melting point of CIMENT FONDU®?
The melting point is 1300 °C. and the boiling point is Not relevant..