NextSDS Logo
Safety Data Sheet EN

DAMICOAT 2407-02 RED

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
DAMICOAT 2407-02 RED
Product Code
352929

Regulatory Identifiers

CAS Number
N/A

Identified Uses

No further relevant information available.

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

V

Von Roll Italia S.r.l.

manufacturer

Via Rigolfo, 73, 10028 TROFARELLO (TO), ITALY

Emergency Contacts

Von Roll Italia S.r.l.

+390116493111

h. 8/12 + 13/17 italian time

National Poisons Information Service (Birmingham Unit)

844 892 0111

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 3 H226
STOT RE Cat. 2 H373
Asp. Tox. Cat. 1 H304
Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
STOT SE Cat. 3 H335
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H226 Flammable liquid and vapour.
H304 May be fatal if swallowed and enters airways.
H315 Causes skin irritation.
H319 Causes serious eye irritation.
H335 May cause respiratory irritation.
H373 May cause damage to the hearing organs through prolonged or repeated exposure.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P301 + P310 IF SWALLOWED: Immediately call a POISON CENTER/ doctor.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P321 Specific treatment (see on this label).
P331 Do NOT induce vomiting.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P405 Store locked up.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
xylene EC: 215-535-7 1330-20-7 25 - 40% Yes
ethylbenzene EC: 202-849-4 100-41-4 3.5 - 7.5% Yes
Idrocarburi, C9, aromatici EC: 918-668-5 --- 2.5 - 4.75% Yes
REACTION MIXTURE OF ETHYLBENZENE AND XYLENES EC: 905-588-0 --- 4.5% Yes
butan-1-ol EC: 200-751-6 71-36-3 2 - 2.1% Yes
Naphtha (petroleum), hydrotreated heavy EC: 919-857-5 64742-48-9 0.7 - 1.2% Yes
n-butyl acetate EC: 204-658-1 123-86-4 1.1% Yes
Acido neodecanoico, sale di cobalto EC: 248-373-0 27253-31-2 0.4 - 0.5% Yes
2-ethylhexanoic acid, zirconium salt 22464-99-9 0.1 - 0.4% Yes
cobalt(II) 2-ethylhexanoate EC: 205-250-6 136-52-7 0.1 - 0.25% Yes
toluene EC: 203-625-9 108-88-3 0.3% Yes
Diidrossido di cobalto EC: 244-166-4 21041-93-0 0.1 - 0.2% Yes
2-n-butyl-benzo[d]isothiazol-3-one EC: 420-590-7 4299-07-4 0.1% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

If symptoms persist consult doctor.

Immediate Medical Attention

Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

During heating or in case of fire poisonous gases are produced.

Firefighter Protection

Mouth respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Mount respiratory protective device. Wear protective equipment. Keep unprotected persons away.

Environmental

Do not allow product to reach sewage system or any water course. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace. Prevent formation of aerosols. Keep ignition sources away - Do not smoke. Protect against electrostatic charges. Keep respiratory protective device available.

Storage

CONSERVARE IN AMBIENTE FRESCO MAX 30°C - STORE IN A COOL PLACE (MAX 30°)

Fire prevention

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

State Under Standard Conditions
---
Metal Corrosion
---
Vapor Pressure
6.7–8.2 hPa
Molecular Weight
---
Boiling Point
Undetermined.
Relative Density
Not determined.
Explosive Limits
---
Odor
Characteristic
Solubility In Fat
---
Appearance
Form: Fluid, Colour: According to product specification
Freezing Point
Undetermined.
Decomposition Temperature
Not determined.
Bulk Density
---
Evaporation Rate
Not determined.
Voc Content
25.29–<47.61 %
Physical State Data
liquid
Colour Intensity
---
Vapor Density
Not determined.
Auto Ignition Temperature
Product is not selfigniting.
Colour
According to product specification
Partition Coefficient
Not determined.
Softening Point
---
Crystallisation Point
---
Form
Fluid
Flash Point
>23–<60 °C
Upper Explosive Limit
7 Vol %
Relative Evaporation Rate
---
Kinematic Viscosity
Not determined.
Properties Status
---
Solidification Point
---
Density
1.1–1.2 g/cm³
Odor Threshold
Not determined.
Solubility In Water
Not miscible or difficult to mix.
Melting Point
Undetermined.
Ph
Not determined.
Lower Explosive Limit
1.1 Vol %
Solubility
---
Cloud Point
---
Dynamic Viscosity
Not determined.
Flammability
Not applicable.
Physical State
Fluid
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

This disposal considerations refer to intact product without external contaminations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1866
Shipping Name
RESIN SOLUTION
Transport Class
3
Packing Group
III
ADR

Warning: Flammable liquids.

IMDG

Warning: Flammable liquids.

IATA

Warning: Flammable liquids.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for DAMICOAT 2407-02 RED?

The signal word is danger.

What is the physical form of DAMICOAT 2407-02 RED?

DAMICOAT 2407-02 RED is a fluid appearing as form: fluid, colour: according to product specification with according to product specification color. It has characteristic odor.

What is DAMICOAT 2407-02 RED used for?

No further relevant information available.

What are the hazard statements for DAMICOAT 2407-02 RED?

This substance has 7 hazard statements:

  • H226: Flammable liquid and vapour.
  • H304: May be fatal if swallowed and enters airways.
  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.
  • H335: May cause respiratory irritation.
  • H373: May cause damage to the hearing organs through prolonged or repeated exposure.
  • H412: Harmful to aquatic life with long lasting effects.

What is the melting point of DAMICOAT 2407-02 RED?

The melting point is Undetermined. and the boiling point is Undetermined..