NextSDS Logo
TA

TANDEMOL ADDITIVE 24

NO SIGNAL WORD fluid liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
TANDEMOL ADDITIVE 24
Product Code
M5603.

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Additive for soluble oils

Overview

TANDEMOL ADDITIVE 24 commonly used additive for soluble oils.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Houghton Deutschland GmbH

undefined

๐Ÿ“

Giselherstr. 57. D-44319. Dortmund. Deutschland.

๐ŸŒ

DE

๐Ÿ“ž

++49 (0)231/9277-0

๐Ÿ“ 

++49 (0)231/9277-120

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Houghton Deutschland GmbH

๐Ÿ“ž

++49 (0)231/9277-222

๐ŸŒ

DE

๐Ÿ•’

08:00-17:00

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Composition Notes

No substances fulfil the criteria set forth in annexe Il section A of the REACH regulation (EC) n 1907/2006.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

In case of big quantities inhaled, move affected person to fresh air, keep warm and allow to rest.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing and wash the skin thoroughly with soap and water.

๐Ÿ‘๏ธ Eye Contact

Rinse eyes thorougly with clean and fresh water.

Symptoms:

redness, pain or visual impairment

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting. In case of swallowing, keep the patient at rest and contact a doctor.

๐Ÿšจ Immediate Medical Attention Required

In case of doubt or if symptoms persist, always call a doctor. Refer the patient to an ophthalmologist, in particular if there is any redness, pain or visual impairment. Contact a doctor in case of swallowing.

Medical Treatment

Treat symptomatically

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
fluid liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Not available
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
-7 [5%]
๐ŸงŠ Melting Point
not specified.
Critical Property
๐Ÿ’จ Boiling Point
not specified.
Critical Property
๐Ÿ”ฅ Flash Point
PE > 100C.
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
not relevant.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
-950 kg/m3
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not specified.
๐Ÿ“Š Decomposition Temperature
not specified.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Dilutable.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
0
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ensure adequate ventilation, if possible with extractor fans at work posts and appopriate general extraction.

๐Ÿงค Hand Protection

Wear suitable protective gloves in the event of prolonged or repeated skin contact. Gloves of appropriate material (i.e. nitrilic rubber, specification: penetration time: level 6, >480 min., thickness 0,9-1 mm; CE-certified acc. EN 374 cat III) Use appropriate protection cream, especially if for safety reasons protective gloves are not advisable.

๐Ÿ‘๏ธ Eye Protection

Avoid contact with eyes. Use eye protectors designed to protect against liquid splashes Before handling, wear safety goggles in accordance with standard EN166.

๐Ÿ˜ท Respiratory Protection

In case of forming of mist or if ventilation is not sufficient it's recommended to wear breathing apparatus (type FFA1P1 according to standard CE EN 405).

๐Ÿฆบ Skin/Body Protection

Work clothing worn by personnel shall be laundered regularly. After contact with the product, all parts of the body that have been soiled must be washed. Standard issue working clothes. Safety shoes or boots - chemical resistant. Avoid long and intensive skin contact. Before working use protection cream. Don't keep lubricant contaminated rags in pockets of working clothes.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for TANDEMOL ADDITIVE 24?

The signal word for this substance is "no signal word".

What is the physical form of TANDEMOL ADDITIVE 24?

TANDEMOL ADDITIVE 24 is a fluid liquid .

What is TANDEMOL ADDITIVE 24 used for?

Additive for soluble oils

What is the melting point of TANDEMOL ADDITIVE 24?

The melting point is not specified. and the boiling point is not specified..