NextSDS Logo
Safety Data Sheet EN

MASTER ALLOY ALUMINIUM-BERYLLIUM

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
MASTER ALLOY ALUMINIUM-BERYLLIUM

Regulatory Identifiers

CAS Number
N/A

Identified Uses

alloying and desoxidising of Al and Mg

Manufacturers & Suppliers

T

TROPAG, Oscar H.Ritter Nachf. GmbH

Bundesstr. 4, D-20146 Hamburg

+49 (0)40 41 40 13-0

Emergency Contacts

Toxic Substance Emergency Call Center North

+49 (0)551 19240

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Alloy

Chemical Name CAS Number Concentration Hazardous
ALUMINIUM METAL EC: 231-072-3 7429-90-5 100% No
BERYLLIUM EC: 231-150-7 7440-41-7 5 - 10% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove affected person from the immediate area. Ensure supply of fresh air. Irregular breathing/no breathing: artificial respiration. Summon a doctor immediately.

Skin contact

Wash off immediately with soap and water.

Eye contact

Separate eyelids, wash the eyes thoroughly with water (15 min.). Eye treatment by an oculist.

Ingestion

Rinse out mouth and give plenty of water to drink. Summon a doctor immediately. Never give anything by mouth to an unconscious person.

Immediate Medical Attention

Summon a doctor immediately.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Instructions

Adapt extinguisher and fire-fighting measures to fire in the environment.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Refer to protective measures listed in sections 7 and 8.

Environmental

Do not discharge into the drains/surface waters/groundwater.

Cleanup methods

Pick up mechanically.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Provide good ventilation of working area. If workplace exposure limits are exceeded, respiratory protection approved for this particular job must be worn.

Storage

Store product in closed containers. Keep container dry in a cool, well-ventilated place.

Fire prevention

No special measures necessary.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Sufficient protection is given wearing suitable protective gloves checked according to i.e. EN 374, in the event of risk of skin contact with the product. Before use, the protective glove should be tested in any case for its specific work-station suitability (i.e. mechanical resistance, product compatibility and antistatic properties). Adhere to the manufacturer's instructions and information relating to the use, storage, care and replacement of protective gloves. Protective gloves shall be replaced immediately when physically damaged or worn. Design operations thus to avoid permanent use of protective gloves.

Eyes

Safety glasses (EN 166)

Respiratory

If workplace exposure limits are exceeded, a respiration protection approved for this particular job must be worn.

Skin/Body

Clothing as usual in the chemical industry.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Physical State Data
solid
State Under Standard Conditions
---
Appearance
---
Colour
silver-grey
Colour Intensity
---
Form
solid
Odor
---
Odor Threshold
---
Ph
---
Melting Point
800 °C
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
---
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used as prescribed.

Incompatible

Acids; Alcalis

Decomposition

Formation of hydrogen in contact with acids.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Allocation of a waste code number, according to the European Waste Catalogue, should be carried out in agreement with the regional waste disposal company.

Waste Codes

Not specified European Waste Catalogue EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

In the form in which it is marketed, the product causes no danger to health for humans through inhalation, swallowing or contact with the skin. There is therefore no obligation to classify/label the product in accordance with appendix VI, no. 9.3, EC Directive 67/548/EEC.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for MASTER ALLOY ALUMINIUM-BERYLLIUM?

The signal word is no signal word.

What is the physical form of MASTER ALLOY ALUMINIUM-BERYLLIUM?

MASTER ALLOY ALUMINIUM-BERYLLIUM is a solid with silver-grey color.

What is MASTER ALLOY ALUMINIUM-BERYLLIUM used for?

alloying and desoxidising of Al and Mg

What is the melting point of MASTER ALLOY ALUMINIUM-BERYLLIUM?

The melting point is 800 °C .