NextSDS Logo
Safety Data Sheet EN

SILIKAL R 17 Hardener

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
SILIKAL R 17 Hardener

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Repair mortar, Acrylic resin

Manufacturers & Suppliers

S

Silikal America

manufacturer

609-B Fertilla Street, Carrolton, GA 30117

770.830.1404

Emergency Contacts

INFOTRAC

1-800-535-5053

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2 H225
Skin Irrit. Cat. 2 H315
Skin Sens. Cat. 1 H317
STOT SE Cat. 3 H335
STOT RE Cat. 2 H373

GHS Pictograms

GHS02 - Flammable

GHS02

GHS06 - Acute toxicity

GHS06

GHS07 - Health hazard

GHS07

GHS08 - Serious health hazard

GHS08

Hazard Statements

H225 Highly flammable liquid and vapor.
H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H335 May cause respiratory irritation.
H373 May cause damage to organs through prolonged or repeated exposure.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. No smoking.
P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P280 Wear protective gloves / eye protection / face protection.
P314 Get medical advice/attention if you feel unwell.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P501 Dispose of contents/container in accordance with local/regional/national/international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of the substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
methyl methacrylate 80-62-6 50 - 100% Yes
N,N-dimethyl-p-toluidine 99-97-8 0.5 - 2.5% Yes

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air and to be sure call for a doctor.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Drink copious amounts of water and provide fresh air. Immediately call a doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Foam, Sand, CO2, extinguishing powder or water spray. Fight larger fire with alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

Exothermic polymerization.

Instructions

Cool endangered receptacles with water spray.

Firefighter Protection

Wear self-contained respiratory protective device.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust). Do not flush with water or aqueous cleansing agents

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Ensure good ventilation/exhaustion at the workplace.

Storage

Store only in the original receptacle. Store in cool, dry conditions in well sealed receptacles. Store receptacle in a well ventilated area. Protect from heat and direct sunlight.

Fire prevention

Keep ignition sources away - Do not smoke. Protect against electrostatic charges.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Workplace must be properly ventilated and monitored to maintain air quality below the TLV.

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation (EN 374). Material of gloves: Butyl rubber, BR. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. For the mixture of chemicals mentioned below the penetration time has to be at least 60 minutes (Permeation according to EN 374 Part 3: Level 3).

Eyes

Tightly sealed goggles

Respiratory

Organic vapour respirators are required only when levels meet or exceed these values. A self-contained breathing apparatus is required in confined spaces. Filter AX or Organic Vapour Cartridge. Recommended filter device for short term use: Filter A

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Water
Not miscible or difficult to mix.
Upper Explosive Limit
12.5 Vol %
Freezing Point
---
Softening Point
---
Physical State
Fluid
Physical State Data
liquid
Colour
Colorless
Bulk Density
---
Relative Evaporation Rate
---
Solubility
---
Molecular Weight
---
Dynamic Viscosity
1 mPas
Boiling Point
100 °C (212 °F)
Metal Corrosion
---
Decomposition Temperature
Not determined.
Vapor Density
Not determined.
Vapor Pressure
38.7 hPa (29 mm Hg)
Solubility In Fat
---
State Under Standard Conditions
---
Appearance
Fluid, Colorless
Solidification Point
---
Odor
Unpleasant
Odor Threshold
Not determined.
Density
0.94 g/cm³ (7.844 lbs/gal)
Form
Fluid
Melting Point
Undetermined.
Cloud Point
---
Voc Content
---
Evaporation Rate
Not determined.
Colour Intensity
---
Flammability
Not applicable.
Crystallisation Point
---
Properties Status
---
Auto Ignition Temperature
430 °C (806 °F)
Relative Density
Not determined.
Ph
Not determined.
Partition Coefficient
Not determined.
Lower Explosive Limit
2.1 Vol %
Explosive Limits
---
Kinematic Viscosity
Not determined.
Flash Point
10 °C (50 °F)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

Exothermic polymerization.

Avoid

Keep away from heat and direct sunlight.

Incompatible

Reacts with peroxides and other radical forming substances.

Decomposition

Hydrocarbons, Carbon monoxide and carbon dioxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must be specially treated adhering to official regulations.

Disposal

Must not be disposed of together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN1247
Shipping Name
Methyl methacrylate monomer, stabilized
Transport Class
3
Packing Group
II
ADR

Warning: Flammable liquids

IMDG

Warning: Flammable liquids

IATA

Warning: Flammable liquids

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for SILIKAL R 17 Hardener?

The signal word is danger.

What is the physical form of SILIKAL R 17 Hardener?

SILIKAL R 17 Hardener is a fluid appearing as fluid, colorless with colorless color. It has unpleasant odor.

What is SILIKAL R 17 Hardener used for?

Repair mortar, Acrylic resin

What are the hazard statements for SILIKAL R 17 Hardener?

This substance has 5 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.
  • H373: May cause damage to organs through prolonged or repeated exposure.

What is the melting point of SILIKAL R 17 Hardener?

The melting point is Undetermined. and the boiling point is 100 °C (212 °F).

Compliance Scanner