NextSDS Logo
SI

SIGMADUR 580 HARDENER

WARNING Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SIGMADUR 580 HARDENER
Product Code
00141219

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Professional applications, Used by spraying. Coating.

Overview

SIGMADUR 580 HARDENER commonly used professional applications, used by spraying. coating..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226
Acute Tox. Category 4 H332
Skin Sens. Category 1 H317
STOT SE Category 3 H335
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapour.
  • H332: Harmful if inhaled.
  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • Wear protective gloves.
  • Wear eye or face protection.
  • Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
  • Avoid breathing vapour.
  • IF INHALED: Remove person to fresh air and keep comfortable for breathing.
  • If skin irritation or rash occurs: Get medical attention.
  • Store in a well-ventilated place. Keep cool.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

PPG Coatings SPRL/BVBA

undefined

๐Ÿ“

Tweemontstraat 104 B-2100 Deurne Belgium

๐ŸŒ

BE

๐Ÿ“ž

+32-33606311

๐Ÿ“ 

+32-33606435

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+31 20 4075210

๐ŸŒ

NL

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs or vPvBs or have been assigned a workplace exposure limit and hence require reporting in this section.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hexamethylene diisocyanate, oligomers
EC: 500-060-2
28182-81-2 75-90% โš ๏ธ Hazardous
n-butyl acetate
EC: 204-658-1
123-86-4 15% โš ๏ธ Hazardous
Solvent naphtha (petroleum), light arom.
EC: 265-199-0
64742-95-6 5-10% โš ๏ธ Hazardous
hexamethylene-di- isocyanate
EC: 212-485-8
822-06-0 0.5% โš ๏ธ Hazardous

Composition Notes

Occupational exposure limits, if available, are listed in Section 8. SUB codes represent substances without registered CAS Numbers.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.

Symptoms:

Harmful if inhaled. May cause respiratory irritation. Exposure to decomposition products may cause a health hazard. Adverse symptoms may include the following: respiratory tract irritation, coughing.

๐Ÿ–๏ธ Skin Contact

Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognised skin cleanser.

Symptoms:

Defatting to the skin. May cause skin dryness and irritation. May cause an allergic skin reaction. Adverse symptoms may include the following: irritation, redness, dryness, cracking.

๐Ÿ‘๏ธ Eye Contact

Check for and remove any contact lenses. Immediately flush eyes with running water for at least 15 minutes, keeping eyelids open.

Symptoms:

No specific data.

๐Ÿฝ๏ธ Ingestion/Swallowing

If swallowed, seek medical advice immediately and show the container or label. Keep person warm and at rest. Do NOT induce vomiting.

Symptoms:

No specific data.

๐Ÿšจ Immediate Medical Attention Required

Seek immediate medical attention (for eye contact). If swallowed, seek medical advice immediately and show the container or label.

Medical Treatment

No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Amine-like.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
>37.78
Critical Property
๐Ÿ”ฅ Flash Point
Closed cup: 55.7
Critical Property
๐Ÿ“Š Freezing Point
Not available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Highest known value: 1.5 kPa (11.3 mm Hg) (at 20) (n-butyl acetate). Weighted average: 0.85 kPa (6.38 mm Hg) (at 20)
๐Ÿ“Š Vapor Density
Highest known value: 4 (Air = 1) (n-butyl acetate).
๐Ÿ“Š Relative Density
1.13
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Material supports combustion. : Yes. Flammability (solid, gas) : Not available.
๐Ÿ“Š Upper Explosive Limit
7.6%
๐Ÿ“Š Lower Explosive Limit
1.29%
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
370C
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Insoluble in the following materials: cold water.
๐Ÿ“Š Partition Coefficient
Not available.
๐Ÿ“Š Solubility In Water
Insoluble in the following materials: cold water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Kinematic (room temperature): >4 cm2/s Kinematic (40C): >0.21 cm2/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapour or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.

๐Ÿงค Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Gloves: butyl rubber

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side shields.

๐Ÿ˜ท Respiratory Protection

By spraying: air-fed respirator. By other operations than spraying, in well ventilated areas, air-fed respirators could be replaced by a combination charcoal filter and particulate filter mask. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1263

๐Ÿ“ฆ Proper Shipping Name

PAINT RELATED MATERIAL

โš ๏ธ Transport Hazard Class

3

๐Ÿ“‹ Packing Group

III

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SIGMADUR 580 HARDENER?

The signal word for this substance is "warning".

What is the physical form of SIGMADUR 580 HARDENER?

SIGMADUR 580 HARDENER is a liquid. with colourless. color. It has amine-like. odor.

What is the solubility of SIGMADUR 580 HARDENER?

Insoluble in the following materials: cold water.

What is SIGMADUR 580 HARDENER used for?

Professional applications, Used by spraying. Coating.

What are the hazard statements for SIGMADUR 580 HARDENER?

This substance has 5 hazard statements: H226: Flammable liquid and vapour. H332: Harmful if inhaled. H317: May cause an allergic skin reaction. H335: May cause respiratory irritation. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of SIGMADUR 580 HARDENER?

The melting point is Not available. and the boiling point is >37.78.