NextSDS Logo
DA

DAB and DAB plus Chromogen Solution

DANGER Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
DAB and DAB plus Chromogen Solution
Product Code
K8000, K8002, K8010, K8012, K8023, K8024, SK001, GV800, K5204,K5207, GV823, GV825, K0620, K1492, K1494, K1497, K3467, K3467, K3468, K3954, K4006, K4007, K4010, K4011, K4065, K5007, K5361, K6807

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory use Container Type: Bottle K8000 // EnVision FLEX DAB+ Chromogen // EnVision FLEX, High pH, (Link) // 3 x 3 mL K8002 // EnVision FLEX DAB+ Chromogen // EnVision FLEX+, Mouse, High pH, (Link) // 3 x 3 mL K8010 // EnVision FLEX DAB+ Chromogen // EnVision FLEX, High pH, (Dako Autostainer / Autostainer Plus) // 3 x 3 mL K8012 // EnVision FLEX DAB+ Chromogen // EnVision FLEX+, Mouse, High pH, (Dako Autostainer / Autostainer Plus) // 3 x 3 mL K8023 // EnVision FLEX DAB+ Chromogen // EnVision FLEX Mini Kit, High pH, (Link) // 1 x 3 mL K8024 // EnVision FLEX DAB+ Chromogen // EnVision FLEX Mini Kit, High pH, (Dako Autostainer / Autostainer Plus) // 1 x 3 mL SK001 // HercepTest DAB Chromogen // HercepTest for Automated Link Platforms // 1 x 1 mL GV800 // EnVision FLEX DAB+ Chromogen (Dako Omnis) // EnVision FLEX, High pH (Dako Omnis) // 8 x 1 mL K5204 // DAB Chromogen // HercepTest // 1 x 0.5 mL K5207 // DAB Chromogen // HercepTest for the Dako Autostainer // 3 x 3 mL GV823 // EnVision FLEX DAB+ Chromogen (Dako Omnis) // EnVision FLEX Mini Kit, High pH (Dako Omnis) // 2 x 1 mL GV825 // EnVision FLEX DAB+ Chromogen (Dako Omnis) // EnVision FLEX DAB+ Substrate Chromogen System (Dako Omnis) // 2 x 1 mL K0620 // DAB Chromogen // Dako GenPoint,Tyramide Signal Amplification System for Biotinylated Probes // 1 x 0.2 mL K1492 // DAB+ Chromogen // EGFR pharmDx // 1 x 1 mL K1494 // DAB+ Chromogen // EGFR pharmDx for the Dako Autostainer // 2 x 3 mL K1497 // DAB Chromogen // CSA II Biotin-free Tyramide Signal Amplification System // 1 x 1 mL K3467 // DAB+ Chromogen // Dako Liquid DAB+ Substrate Chromogen System // 1 x 1 mL K3468 // DAB+ Chromogen // Dako Liquid DAB+ Substrate Chromogen System // 1 x 5 mL K3954 // DAB+ Chromogen // Dako ARK (Animal Research Kit), Peroxidase for Mouse Primary Antibodies // 1 x 1 mL K4006 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Mouse Primary Antibodies // 1 x 1 mL K4007 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Mouse Primary Antibodies // 1 x 5 mL K4010 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Rabbit Primary Antibodies // 1 x 1 mL K4011 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Rabbit Primary Antibodies // 1 x 5 mL K4065 // DAB+ Chromogen // Dako EnVision+ Dual Link System-HRP (DAB+) // 1 x 1 mL K5007 // DAB+ Chromogen (x 50) // Dako REAL EnVision Detection System, Peroxidase/DAB+, Rabbit/Mouse // 5 mL K5361 // DAB+ Chromogen // EnVision G|2 Doublestain System, Rabbit/Mouse (DAB+/Permanent Red) // 1 x 1.5 mL K6807 // EnVision DuoFLEX DAB+ Chromogen // EnVision DuoFLEX Doublestain System (Dako Autostainer / Autostainer Plus) // 1 x 1.8 mL

Overview

DAB and DAB plus Chromogen Solution commonly used laboratory use container type: bottle k8000 // envision flex dab+ chromogen // envision flex, high ph, (link) // 3 x 3 ml k8002 // envision flex dab+ chromogen // envision flex+, mouse, high ph, (link) // 3 x 3 ml k8010 // envision flex dab+ chromogen // envision flex, high ph, (dako autostainer / autostainer plus) // 3 x 3 ml k8012 // envision flex dab+ chromogen // envision flex+, mouse, high ph, (dako autostainer / autostainer plus) // 3 x 3 ml k8023 // envision flex dab+ chromogen // envision flex mini kit, high ph, (link) // 1 x 3 ml k8024 // envision flex dab+ chromogen // envision flex mini kit, high ph, (dako autostainer / autostainer plus) // 1 x 3 ml sk001 // herceptest dab chromogen // herceptest for automated link platforms // 1 x 1 ml gv800 // envision flex dab+ chromogen (dako omnis) // envision flex, high ph (dako omnis) // 8 x 1 ml k5204 // dab chromogen // herceptest // 1 x 0.5 ml k5207 // dab chromogen // herceptest for the dako autostainer // 3 x 3 ml gv823 // envision flex dab+ chromogen (dako omnis) // envision flex mini kit, high ph (dako omnis) // 2 x 1 ml gv825 // envision flex dab+ chromogen (dako omnis) // envision flex dab+ substrate chromogen system (dako omnis) // 2 x 1 ml k0620 // dab chromogen // dako genpoint,tyramide signal amplification system for biotinylated probes // 1 x 0.2 ml k1492 // dab+ chromogen // egfr pharmdx // 1 x 1 ml k1494 // dab+ chromogen // egfr pharmdx for the dako autostainer // 2 x 3 ml k1497 // dab chromogen // csa ii biotin-free tyramide signal amplification system // 1 x 1 ml k3467 // dab+ chromogen // dako liquid dab+ substrate chromogen system // 1 x 1 ml k3468 // dab+ chromogen // dako liquid dab+ substrate chromogen system // 1 x 5 ml k3954 // dab+ chromogen // dako ark (animal research kit), peroxidase for mouse primary antibodies // 1 x 1 ml k4006 // dab+ chromogen // dako envision+ system-hrp (dab), for use with mouse primary antibodies // 1 x 1 ml k4007 // dab+ chromogen // dako envision+ system-hrp (dab), for use with mouse primary antibodies // 1 x 5 ml k4010 // dab+ chromogen // dako envision+ system-hrp (dab), for use with rabbit primary antibodies // 1 x 1 ml k4011 // dab+ chromogen // dako envision+ system-hrp (dab), for use with rabbit primary antibodies // 1 x 5 ml k4065 // dab+ chromogen // dako envision+ dual link system-hrp (dab+) // 1 x 1 ml k5007 // dab+ chromogen (x 50) // dako real envision detection system, peroxidase/dab+, rabbit/mouse // 5 ml k5361 // dab+ chromogen // envision g|2 doublestain system, rabbit/mouse (dab+/permanent red) // 1 x 1.5 ml k6807 // envision duoflex dab+ chromogen // envision duoflex doublestain system (dako autostainer / autostainer plus) // 1 x 1.8 ml.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Muta. Category 2 H341
Carc. Category 1B H350

GHS Hazard Pictograms & Safety Symbols

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H350: May cause cancer.
  • H341: Suspected of causing genetic defects.

Precautionary Statements

  • P201: Obtain special instructions before use.
  • P280: Wear protective gloves. Wear eye or face protection. Wear protective clothing.
  • IF exposed or concerned: Get medical attention.
  • P405: Store locked up.
  • P501: Dispose of contents and container in accordance with all local, regional, national and international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Dako Denmark A/S company logo - Safety Data Sheet supplier organization

Dako Denmark A/S

global supplier

๐Ÿ“

Produktionsvej 42 DK-2600 Glostrup

๐ŸŒ

DK

๐Ÿ“ž

+45 44 85 95 00

๐ŸŒ www.Dako.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

+(44)-870-8200418

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
biphenyl-3,3',4,4'tetrayltetraammonium tetrachloride
EC: 231-018-9
7411-49-6 5-10% โš ๏ธ Hazardous

Composition Notes

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Get medical attention immediately. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If it is suspected that fumes are still present, the rescuer should wear an appropriate mask or self-contained breathing apparatus. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.

Symptoms:

No specific data.

๐Ÿ–๏ธ Skin Contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. Wash clothing before reuse. Clean shoes thoroughly before reuse.

Symptoms:

No specific data.

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Continue to rinse for at least 10 minutes. Get medical attention if irritation occurs.

Symptoms:

No specific data.

๐Ÿฝ๏ธ Ingestion/Swallowing

Get medical attention immediately. Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.

Symptoms:

No specific data.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention immediately for inhalation and ingestion. Get medical attention if irritation occurs for eye contact. Get medical attention for skin contact. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.

Medical Treatment

No specific treatment.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Amber.
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
Not available.
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable.
Critical Property
๐Ÿ“Š Freezing Point
Not available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
Not available.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available.
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
Soluble in the following materials: cold water and hot water.
๐Ÿ“Š Partition Coefficient
Not available.
๐Ÿ“Š Solubility In Water
Soluble in the following materials: cold water and hot water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

If user operations generate dust, fumes, gas, vapour or mist, use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits.

๐Ÿงค Hand Protection

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated.

๐Ÿ‘๏ธ Eye Protection

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with sideshields.

๐Ÿ˜ท Respiratory Protection

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

๐Ÿฆบ Skin/Body Protection

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for DAB and DAB plus Chromogen Solution?

The signal word for this substance is "danger".

What is the physical form of DAB and DAB plus Chromogen Solution?

DAB and DAB plus Chromogen Solution is a liquid. with amber. color. It has not available. odor.

What is the solubility of DAB and DAB plus Chromogen Solution?

Soluble in the following materials: cold water and hot water.

What is DAB and DAB plus Chromogen Solution used for?

Laboratory use Container Type: Bottle K8000 // EnVision FLEX DAB+ Chromogen // EnVision FLEX, High pH, (Link) // 3 x 3 mL K8002 // EnVision FLEX DAB+ Chromogen // EnVision FLEX+, Mouse, High pH, (Link) // 3 x 3 mL K8010 // EnVision FLEX DAB+ Chromogen // EnVision FLEX, High pH, (Dako Autostainer / Autostainer Plus) // 3 x 3 mL K8012 // EnVision FLEX DAB+ Chromogen // EnVision FLEX+, Mouse, High pH, (Dako Autostainer / Autostainer Plus) // 3 x 3 mL K8023 // EnVision FLEX DAB+ Chromogen // EnVision FLEX Mini Kit, High pH, (Link) // 1 x 3 mL K8024 // EnVision FLEX DAB+ Chromogen // EnVision FLEX Mini Kit, High pH, (Dako Autostainer / Autostainer Plus) // 1 x 3 mL SK001 // HercepTest DAB Chromogen // HercepTest for Automated Link Platforms // 1 x 1 mL GV800 // EnVision FLEX DAB+ Chromogen (Dako Omnis) // EnVision FLEX, High pH (Dako Omnis) // 8 x 1 mL K5204 // DAB Chromogen // HercepTest // 1 x 0.5 mL K5207 // DAB Chromogen // HercepTest for the Dako Autostainer // 3 x 3 mL GV823 // EnVision FLEX DAB+ Chromogen (Dako Omnis) // EnVision FLEX Mini Kit, High pH (Dako Omnis) // 2 x 1 mL GV825 // EnVision FLEX DAB+ Chromogen (Dako Omnis) // EnVision FLEX DAB+ Substrate Chromogen System (Dako Omnis) // 2 x 1 mL K0620 // DAB Chromogen // Dako GenPoint,Tyramide Signal Amplification System for Biotinylated Probes // 1 x 0.2 mL K1492 // DAB+ Chromogen // EGFR pharmDx // 1 x 1 mL K1494 // DAB+ Chromogen // EGFR pharmDx for the Dako Autostainer // 2 x 3 mL K1497 // DAB Chromogen // CSA II Biotin-free Tyramide Signal Amplification System // 1 x 1 mL K3467 // DAB+ Chromogen // Dako Liquid DAB+ Substrate Chromogen System // 1 x 1 mL K3468 // DAB+ Chromogen // Dako Liquid DAB+ Substrate Chromogen System // 1 x 5 mL K3954 // DAB+ Chromogen // Dako ARK (Animal Research Kit), Peroxidase for Mouse Primary Antibodies // 1 x 1 mL K4006 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Mouse Primary Antibodies // 1 x 1 mL K4007 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Mouse Primary Antibodies // 1 x 5 mL K4010 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Rabbit Primary Antibodies // 1 x 1 mL K4011 // DAB+ Chromogen // Dako EnVision+ System-HRP (DAB), For Use With Rabbit Primary Antibodies // 1 x 5 mL K4065 // DAB+ Chromogen // Dako EnVision+ Dual Link System-HRP (DAB+) // 1 x 1 mL K5007 // DAB+ Chromogen (x 50) // Dako REAL EnVision Detection System, Peroxidase/DAB+, Rabbit/Mouse // 5 mL K5361 // DAB+ Chromogen // EnVision G|2 Doublestain System, Rabbit/Mouse (DAB+/Permanent Red) // 1 x 1.5 mL K6807 // EnVision DuoFLEX DAB+ Chromogen // EnVision DuoFLEX Doublestain System (Dako Autostainer / Autostainer Plus) // 1 x 1.8 mL

What are the hazard statements for DAB and DAB plus Chromogen Solution?

This substance has 2 hazard statements: H350: May cause cancer. H341: Suspected of causing genetic defects.

What is the melting point of DAB and DAB plus Chromogen Solution?

The melting point is Not available. and the boiling point is Not available..