NextSDS Logo
Ca

Castrol EDGE 5W-30

NO SIGNAL WORD Liquid. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Castrol EDGE 5W-30
Product Form
Liquid.
Product Code
463740-BE02

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Automotive engine crankcase lubricant. For specific application advice see appropriate Technical Data Sheet or consult our company representative.

Overview

Castrol EDGE 5W-30 commonly used automotive engine crankcase lubricant. for specific application advice see appropriate technical data sheet or consult our company representative..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (No signal word.)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

BP Lubricants, onderdeel van BP Europa SE - BP Belgium

national supplier

๐Ÿ“

Amocolaan 2 2440 Geel

๐ŸŒ

BE

๐Ÿ“ž

03 2860811

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Carechem

๐Ÿ“ž

+44 (0) 1235 239 670

๐ŸŒ

GB

๐Ÿ•’

24/7

Antipoison Centre

๐Ÿ“ž

070 245 245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixture

General Composition

Chemically modified base oil. Proprietary performance additives.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Base oil - unspecified N/A Not specified โš ๏ธ Hazardous
Distillates (petroleum), hydrotreated heavy paraffinic
EC: 265-157-1
64742-54-7 25-50% โš ๏ธ Hazardous
Base oil - unspecified N/A 25-50% โœ“ Non-hazardous

Additional Information

Occupational exposure limits, if available, are listed in Section 8.

Composition Notes

See Section 16 for the full text of the H statements declared above.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

If inhaled, remove to fresh air. Get medical attention if symptoms appear.

๐Ÿ–๏ธ Skin Contact

Wash skin thoroughly with soap and water or use recognised skin cleanser. Remove contaminated clothing and shoes. Wash clothing before reuse. Clean shoes thoroughly before reuse. Get medical attention if irritation develops.

๐Ÿ‘๏ธ Eye Contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Eyelids should be held away from the eyeball to ensure thorough rinsing. Check for and remove any contact lenses. Get medical attention.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

๐Ÿšจ Immediate Medical Attention Required

Get medical attention if irritation develops (skin), if symptoms appear (inhalation), or if symptoms occur (ingestion). Treatment should in general be symptomatic and directed to relieving any effects.

Medical Treatment

Treatment should in general be symptomatic and directed to relieving any effects.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid.
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Amber. [Light]
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Not available.
๐Ÿ“Š Odor Threshold
Not available.
๐Ÿงช Ph
Not available.
๐ŸงŠ Melting Point
Not available.
Critical Property
๐Ÿ’จ Boiling Point
Not available.
Critical Property
๐Ÿ”ฅ Flash Point
Closed cup: 202C (395.6F) [Pensky-Martens.]
Critical Property
๐Ÿ“Š Freezing Point
Not available.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available.
๐Ÿ’จ Vapor Pressure
Not available.
๐Ÿ“Š Vapor Density
Not available.
๐Ÿ“Š Relative Density
Not available.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
851.3 kg/m (0.851 g/cm) at 15C
Critical Property
๐Ÿ”ฅ Flammability
Not available.
๐Ÿ“Š Upper Explosive Limit
Not available.
๐Ÿ“Š Lower Explosive Limit
Not available.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available.
๐Ÿ“Š Decomposition Temperature
Not available.
๐Ÿ’ง Solubility
insoluble in water.
๐Ÿ“Š Partition Coefficient
Not available.
๐Ÿ“Š Solubility In Water
insoluble in water.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Kinematic: 70 mm [2] /s (70 cSt) at 40C Kinematic: 12 mm [2] /s (12 cSt) at 100C
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide exhaust ventilation or other engineering controls to keep the relevant airborne concentrations below their respective occupational exposure limits. All activities involving chemicals should be assessed for their risks to health, to ensure exposures are adequately controlled. Personal protective equipment should only be considered after other forms of control measures (e.g. engineering controls) have been suitably evaluated. Personal protective equipment should conform to appropriate standards, be suitable for use, be kept in good condition and properly maintained. Your supplier of personal protective equipment should be consulted for advice on selection and appropriate standards. For further information contact your national organisation for standards. The final choice of protective equipment will depend upon a risk assessment. It is important to ensure that all items of personal protective equipment are compatible.

๐Ÿงค Hand Protection

General Information: Because specific work environments and material handling practices vary, safety procedures should be developed for each intended application. The correct choice of protective gloves depends upon the chemicals being handled, and the conditions of work and use. Most gloves provide protection for only a limited time before they must be discarded and replaced (even the best chemically resistant gloves will break down after repeated chemical exposures). Gloves should be chosen in consultation with the supplier / manufacturer and taking account of a full assessment of the working conditions. Recommended: Nitrile gloves. Breakthrough time: Breakthrough time data are generated by glove manufacturers under laboratory test conditions and represent how long a glove can be expected to provide effective permeation resistance. It is important when following breakthrough time recommendations that actual workplace conditions are taken into account. Always consult with your glove supplier for up-to-date technical information on breakthrough times for the recommended glove type. Our recommendations on the selection of gloves are as follows: Continuous contact: Gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. If suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to. Short-term / splash protection: Recommended breakthrough times as above. It is recognised that for short-term, transient exposures, gloves with shorter breakthrough times may commonly be used. Therefore, appropriate maintenance and replacement regimes must be determined and rigorously followed. Glove Thickness: For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. It should be emphasised that glove thickness is not necessarily a good predictor of glove resistance to a specific chemical, as the permeation efficiency of the glove will be dependent on the exact composition of the glove material. Therefore, glove selection should also be based on consideration of the task requirements and knowledge of breakthrough times. Glove thickness may also vary depending on the glove manufacturer, the glove type and the glove model. Therefore, the manufacturers technical data should always be taken into account to ensure selection of the most appropriate glove for the task. Note: Depending on the activity being conducted, gloves of varying thickness may be required for specific tasks. For example: - Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. However, these gloves are only likely to give short duration protection and would normally be just for single use applications, then disposed of. - Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential. Refer to standards: Gloves: EN 420, EN 374

๐Ÿ‘๏ธ Eye Protection

Safety glasses with side shields. Refer to standards: Eye protection: EN 166

๐Ÿ˜ท Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Refer to standards: Respiratory protection: EN 529

๐Ÿฆบ Skin/Body Protection

Use of protective clothing is good industrial practice. Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Cotton or polyester/cotton overalls will only provide protection against light superficial contamination that will not soak through to the skin. Overalls should be laundered on a regular basis. When the risk of skin exposure is high (e.g. when cleaning up spillages or if there is a risk of splashing) then chemical resistant aprons and/or impervious chemical suits and boots will be required.

๐ŸŒ Environmental Exposure Controls

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Castrol EDGE 5W-30?

The signal word for this substance is "no signal word".

What is the physical form of Castrol EDGE 5W-30?

Castrol EDGE 5W-30 is a liquid. with amber. [light] color. It has not available. odor.

What is the solubility of Castrol EDGE 5W-30?

insoluble in water.

What is Castrol EDGE 5W-30 used for?

Automotive engine crankcase lubricant. For specific application advice see appropriate Technical Data Sheet or consult our company representative.

What is the melting point of Castrol EDGE 5W-30?

The melting point is Not available. and the boiling point is Not available..