NextSDS Logo
Safety Data Sheet EN

Faramount Aqueous Mounting Medium

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Faramount Aqueous Mounting Medium
Product Code
S3025

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory use

Manufacturers & Suppliers

Dako Denmark A/S logo

Dako Denmark A/S

manufacturer

Produktionsvej 42, DK-2600 Glostrup

+45 44 85 95 00

www.Dako.com

Emergency Contacts

CHEMTREC®

+(44)-870-8200418

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.

Chemical Name CAS Number Concentration Hazardous
Trometamol EC: 201-064-4 77-86-1 1 - 3% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.

Symptoms: Exposure to decomposition products may cause a health hazard. Serious effects may be delayed following exposure.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No known significant effects or critical hazards.

Ingestion

Wash out mouth with water. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No known significant effects or critical hazards.

Immediate Medical Attention

Get medical attention if irritation occurs (eye contact) or if symptoms occur (inhalation, skin contact, ingestion). In case of inhalation of decomposition products in a fire, symptoms may be delayed, and the exposed person may need to be kept under medical surveillance for 48 hours.

Medical Treatment

No specific treatment. In case of inhalation of decomposition products in a fire, symptoms may be delayed. The exposed person may need to be kept under medical surveillance for 48 hours.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use an extinguishing agent suitable for the surrounding fire.

Unsuitable media

None known.

Specific hazards

In a fire or if heated, a pressure increase will occur and the container may burst.

Instructions

Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.

Firefighter Protection

Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilt material. Put on appropriate personal protective equipment.

Environmental

Avoid dispersal of spilt material and runoff and contact with soil, waterways, drains and sewers.

Cleanup methods

Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Put on appropriate personal protective equipment (see Section 8).

Storage

Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabelled containers.

Hygiene

Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid. [Clear.]
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Colourless.
Colour Intensity
---
Form
---
Odor
Odourless.
Odor Threshold
Not available.
Ph
8.8
Melting Point
Not available.
Boiling Point
Not available.
Flash Point
Not available.
Freezing Point
Not available.
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
Not available.
Vapor Density
Not available.
Relative Density
Not available.
Bulk Density
---
Density
---
Flammability
Not applicable.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
Soluble in the following materials: cold water and hot water.
Partition Coefficient
Not available.
Solubility In Water
Soluble in the following materials: cold water and hot water.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

12.1 Toxicity Conclusion/Summary : Not available.

Not available.

12.2 Persistence and degradability

Conclusion/Summary : Not available.

Not available.

12.3 Bioaccumulative potential

12.3 Bioaccumulative potential Date of issue/Date of revision : 28/05/2015 Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - Europe | Faramount Aqueous Mounting Medium | | | | | --- | --- | --- | --- | | SECTION 12: Ecological information | | | | | Product/ingredient name | LogPow | BCF | Potential | | Trometamol | -1.56 | - | low |

12.4 Mobility in soil

Soil/water partition : Not available. coefficient (Koc) Mobility : Not available.

No data available regarding mobility in soil.

12.5 Results of PBT and vPvB assessment

PBT : Not applicable. vPvB : Not applicable.

The substance is not considered to be PBT or vPvB.

12.6 Other adverse effects

No known significant effects or critical hazards.

No known significant effects or critical hazards.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

None of the components are listed in Annex XIV or as SVHC. Product is not controlled under the Seveso II Directive.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Faramount Aqueous Mounting Medium?

The signal word is no signal word.

What is the physical form of Faramount Aqueous Mounting Medium?

Faramount Aqueous Mounting Medium is a liquid. [clear.] with colourless. color. It has odourless. odor.

What is the solubility of Faramount Aqueous Mounting Medium?

Soluble in the following materials: cold water and hot water.

What is Faramount Aqueous Mounting Medium used for?

Laboratory use

What is the melting point of Faramount Aqueous Mounting Medium?

The melting point is Not available. and the boiling point is Not available..