Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Triethyl citrate
Regulatory Identifiers
- CAS Number
- 77-93-0 Check regulations →
- EC Number
- 201-070-7 Check regulations →
- REACH No.
- 01-2119955435-32-0004
Identified Uses
Triethyl citrate is used as solvent, diluent and fixative by perfumers. It is well accepted as an active ingredient in deodorants. In pharmaceutical applications Triethyl citrate contributes as plasticiser to the performance of enteric-coated tablets.
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
Mamta Polycoats
manufacturer
244/P, Padra-Jambusar Road, Dhobikuva(Vill.)-391440, Padra, Vadodara
+91 2662 267230
http://www.mamtapolycoats.com
Emergency Contacts
European importer
+91 98240 72230
EN
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| triethyl citrate EC: 201-070-7 | 77-93-0 | --- | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Take affected [persons ] out of danger area and [lay down.]
Wash off immediately with soap and [plenty ] of water. lf skin irritation [persisfs, ] [call ] [a ] [physician.]
Remove contact /enses, if [present ] and easy to do. Rinse immediately wth plenty of water and seek medical advice.
Do not induce vomiting. Consult a physician if necessary.
Medical Treatment
Treat symptomatically and supportively.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use fire extinguishing methods suitable to surrounding conditions. Water spray, dry powder, foam, carbon dioxide (CO2)
Water with full jet.
Formation of toxic gases is possible during heating or in case of fire.
Standard procedure for chemical fires. Cool endangered receptacles with water spray.
Firefighter Protection
Wear self-contained respiratory protective device. Use personal protective equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow to enter sewers/ surface or ground water.
Soak up with inert absorbent material
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use personal protective equipment. Do not breathe dust/fume/gas/mist/vapours/spray. Avoid skin and eye contact.
Store in a cool, dry, well-ventilated area away from incompatible substances. Store in original container.
Keep ignition sources away - Do not smoke. Standard procedure for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure good ventilation/exhaustion at the workplace.
Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. The exact breakthrough time has to be found out by the manufacturer of the protective gloves and has to be observed.
Tightly sealed goggles
Not necessary if room is well-ventilated. In case of brief exposure or low pollution use respiratory filter device. In case of intensive or longer exposure use self-contained respiratory protective device.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.2 Persistence and degradability
The substance triethyl citrate is considered to be readily biodegradable, with a mean degradation of 78% determined within 28 days.
12.3 Bioaccumulative potential
The substance is not expected to bioaccumulate, with a calculated BCF of 2.75 L/kg.
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance is not considered to be PBT or vPvB.
12.6 Other adverse effects
No further relevant information available.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not applicable
- Shipping Name
- Not applicable
- Transport Class
- Not applicable
- Packing Group
- Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Triethyl citrate?
The signal word is no signal word.
What is the physical form of Triethyl citrate?
Triethyl citrate is a liquid appearing as liquid colourless characteristic odour with colourless color. It has characteristic odour odor.
What is Triethyl citrate used for?
Triethyl citrate is used as solvent, diluent and fixative by perfumers. It is well accepted as an active ingredient in deodorants. In pharmaceutical applications Triethyl citrate contributes as plasticiser to the performance of enteric-coated tablets.
What is the melting point of Triethyl citrate?
The melting point is < -40 "C and the boiling point is 286.8'C (at 101.3 kPa).