NextSDS Logo
Safety Data Sheet EN

OMM Green 100

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
OMM Green 100

Regulatory Identifiers

CAS Number
N/A

Manufacturers & Suppliers

N

NDT Europa BV

Damsluisweg 77 1332 EB Almere

+31 (0)36 5495000

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Xn
N
Carc. Cat. 3
Xn
N

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

The data for this section has not been processed yet.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If inhaled, remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention if symptoms appear.

Skin contact

In case of contact, immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash clothing before reuse. Thoroughly clean shoes before reuse. Get medical attention immediately.

Eye contact

In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Get medical attention immediately.

Ingestion

Do NOT induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to an unconscious person. If large quantities of this material are swallowed, call a physician immediately.

Immediate Medical Attention

Get medical attention if symptoms appear (for inhalation). If large quantities of this material are swallowed, call a physician immediately. Get medical attention immediately (for skin and eye contact).

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide exhaust ventilation or other engineering controls to keep the airborne concentrations of vapors below their respective occupational exposure limits. Ensure that eyewash stations and safety showers are proximal to the work-station location.

Hands

Chemical-resistant, impervious gloves or gauntlets complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Recommended, Latex gloves. Nitrile gloves.

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists or dusts. Recommended, Safety glasses.

Respiratory

Use a properly fitted, air-purifying or air-fed respirator complying with an approved standard if a risk assessment indicates this is necessary.Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. When using a liquid based on organic compound: - Recommended for organic vapour (type A) When using a dry powder: - Recommended for particulate filters (type P)

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Recommended, Protective Clothing (e.g.lab coat)

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Green.
Colour Intensity
---
Form
---
Odor
Characteristic.
Odor Threshold
---
Ph
---
Melting Point
Not available.
Boiling Point
The lowest known value is >179C (354.2F) (Solvent naphtha (petroleum), heavy arom.).
Flash Point
Closed cup: Between 61C (142F) and 93.3C (200F).
Freezing Point
Not available.
Softening Point
---
Solidification Point
---
Cloud Point
Not available.
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
<1 (Solvent naphtha (petroleum), heavy arom.) compared to Butyl acetate.
Vapor Pressure
Weighted average: 0.1 kPa (0.75 mm Hg) (at 20C)
Vapor Density
---
Relative Density
0.986 (Water = 1)
Bulk Density
---
Density
---
Flammability
---
Upper Explosive Limit
5.6%
Lower Explosive Limit
1%
Explosive Limits
---
Auto Ignition Temperature
445C (833F)
Decomposition Temperature
---
Solubility
Not available.
Partition Coefficient
---
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
90% (w/w).
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
Kinematic (40C): <7 mm/s
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN 3082
Shipping Name
Environmentally hazardous substance, liquid, n.o.s. (Solvent naphtha (petroleum), heavy arom.)
Transport Class
9
Packing Group
III
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for OMM Green 100?

The signal word is no signal word.

What is the physical form of OMM Green 100?

OMM Green 100 is a liquid. with green. color. It has characteristic. odor.

What is the solubility of OMM Green 100?

Not available.

What is the melting point of OMM Green 100?

The melting point is Not available. and the boiling point is The lowest known value is >179C (354.2F) (Solvent naphtha (petroleum), heavy arom.)..