Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 1,2,4-Butanetriol standard solution
- Product Code
- CL40.0272
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- is not available for this substance as the substance or its use are exempted from registration according to Article 2 REACH Regulation (EC) No 1907/2006, the annual tonnage does not require a registration or the registration is envisaged for a later registration deadline.
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
CHEM-LAB NV
manufacturer
Industriezone "De Arend" 2, B-8210 Zedelgem, BELGIUM
+32 50 28 83 20
Emergency Contacts
CHEM-LAB NV
00 (32) 50.28.83.20
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Fresh air. If necessary, apply mechanical ventilation. Keep airways free. Immediately call in physician.
Wash off with plenty of water. Remove contaminated clothing.
Rinse out with plenty of water for at least 10 minutes with the eyelid held wide open. Immediately call an ophthalmologist.
Never give anything by mouth to an unconscious person. Immediately make victim drink water (two glasses at most). Call in physician.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical or carbon dioxide.
Cool container with spray water from a save distance. Contain escaping vapours with water. Prevent fire-fighting water from entering surface water or groundwater.
Combustible. Vapours heavier than air. Forms explosive mixtures with air at ambient temperatures. Development of hazardous combustion gases or vapours possible in the event of fire.
Cool container with spray water from a save distance. Contain escaping vapours with water.
Firefighter Protection
Do not stay in dangerous zone without self-contained breathing apparatus and wear suitable protective clothing.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid substance contact. Avoid generation of dusts, do not inhale dusts. Ensure supply of fresh air in enclosed rooms.
Do not allow to enter sewerage system; risk of explosion!
Absorb on vermiculite, sand or a pillow from Chemical Spill Center.
Materials: vermiculite, sand or a pillow from Chemical Spill Center
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not inhale substance.
Closed in a well ventilated place. Recommended storage temperature see product label.
Keep away from sources of ignition. Take measures to prevent electrostatic charging. Away from sources of ignition and heat.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Work under hood.
Required.
Required.
Wear gas mask. The entrepreneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Required. Protective clothing should be selected specifically for the working place, depending on concentration and quantity of the hazardous substances handled. The resistance of the protective clothing to chemicals should be ascertained with the respective supplier.
Do not allow to enter sewerage system; risk of explosion!
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No further relevant information available.
See section 10.3
Explosible with air in a vaporous/gaseous state when heated
No further relevant information available.
No further relevant information available.
No further relevant information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemicals must be disposed of in compliance with the respective national regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1282
- Shipping Name
- Pyridine
- Transport Class
- 3
- Packing Group
- II
no
no
no
Regulatory Information
Chemical regulations, safety assessments, and compliance status
For this product an assessment was not carried out.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 1,2,4-Butanetriol standard solution?
The signal word is danger.
What is the physical form of 1,2,4-Butanetriol standard solution?
1,2,4-Butanetriol standard solution is a liquid appearing as form: liquid, colour: colourless, odour: specific with colourless color. It has specific odor.
What is 1,2,4-Butanetriol standard solution used for?
Reagent for analysis
What are the hazard statements for 1,2,4-Butanetriol standard solution?
This substance has 2 hazard statements:
- H225: Highly flammable liquid and vapour.
- H302 + H312 + H332: Harmful if swallowed, in contact with skin or if inhaled.
What is the melting point of 1,2,4-Butanetriol standard solution?
The melting point is -42°C and the boiling point is 115°C.