Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Dimethyl glutarate
- Product Code
- B24359
- Chemical Name
- Dimethyl glutarate
Regulatory Identifiers
- CAS Number
- 1119-40-0 Check regulations →
- EC Number
- 214-277-2 Check regulations →
Identified Uses
Laboratory chemicals.
Uses advised against
No Information available
Manufacturers & Suppliers
Avocado Research Chemicals Ltd.
manufacturer
Shore Road, Heysham, Lancashire, LA3 2XY, United Kingdom
+44 (0) 1524 850506
Emergency Contacts
For information US
001-800-227-6701
Europe call
+32 14 57 52 11
Emergency Number US
001-201-796-7100
Europe
+32 14 57 52 99
CHEMTREC Tel. No. US
001-800-424-9300
Europe
001-703-527-3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Dimethyl glutarate EC: 214-277-2 | 1119-40-0 | 95% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Get medical attention immediately if symptoms occur.
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Immediate Medical Attention
Get medical attention immediately if symptoms occur.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, carbon dioxide (CO2), dry chemical, alcohol-resistant foam.
No information available.
Thermal decomposition can lead to release of irritating gases and vapors.
Firefighter Protection
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment as required.
Should not be released into the environment. See Section 12 for additional Ecological Information.
Sweep up and shovel into suitable containers for disposal.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Ensure adequate ventilation. Wear personal protective equipment/face protection. Avoid contact with skin, eyes or clothing. Avoid ingestion and inhalation. Avoid dust formation.
Keep containers tightly closed in a dry, cool and well-ventilated place.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and after work.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
None under normal use conditions.
Protective gloves. Glove material: Nitrile rubber, Neoprene, Natural rubber, PVC. Breakthrough time: See manufacturers recommendations. Glove thickness: See manufacturers recommendations. EU standard: EN 374 (minimum requirement). Inspect gloves before use. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. (Refer to manufacturer/supplier for information) Ensure gloves are suitable for the task: Chemical compatability, Dexterity, Operational conditions, User susceptibility, e.g. sensitisation effects, also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Remove gloves with care avoiding skin contamination.
Wear safety glasses with side shields (or goggles) (European standard - EN 166)
No protective equipment is needed under normal use conditions. Large scale/emergency use: Use a NIOSH/MSHA or European Standard EN 136 approved respirator if exposure limits are exceeded or if irritation or other symptoms are experienced. Recommended Filter type: Particle filter. Small scale/Laboratory use: Maintain adequate ventilation. Recommended half mask:- Valve filtering: EN405; or; Half mask: EN140; plus filter, EN 141
Wear appropriate protective gloves and clothing to prevent skin exposure.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
None known, based on information available
Hazardous polymerization does not occur. None under normal processing.
Incompatible products. Excess heat. Avoid dust formation.
Acids. Bases. Reducing Agent.
Carbon monoxide (CO). Carbon dioxide (CO₂).
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.2. Persistence and degradability
The substance is readily biodegradable.
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5. Results of PBT and vPvB assessment
The substance is not classified as PBT or vPvB.
12.6. Endocrine disrupting properties
The product does not contain any known or suspected endocrine disruptors.
12.7. Other adverse effects
The product does not contain any known or suspected persistent organic pollutants or substances that deplete the ozone layer.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. Consult local, regional, and national hazardous waste regulations to ensure complete and accurate classification.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Safety, health and environmental regulations/legislation specific for the substance or mixture.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Dimethyl glutarate?
The signal word is no signal word.
What is the physical form of Dimethyl glutarate?
Dimethyl glutarate is a liquid appearing as colorless with colorless color. It has odorless odor.
What is the solubility of Dimethyl glutarate?
No information available
What is Dimethyl glutarate used for?
Laboratory chemicals.
What is the melting point of Dimethyl glutarate?
The melting point is -37 C / -34.6 F and the boiling point is 210 - 215 C / 410 - 419 F @ 760 mmHg.