Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Vacuum Gasoil
Regulatory Identifiers
- CAS Number
- N/A
Manufacturers & Suppliers
PETRONAS Penapisan (Melaka) Sdn. Bhd.
manufacturer
Persiaran Penapisan, 76300 Sungai Udang, Melaka, Malaysia
Emergency Contacts
Fire Station Radio Operator
(+606)-352 2444
National Poison Centre
+604-6570099
Mon-Fri : 8.10 am - 5.10 pm
National Poison Centre
+6012-4309499
Mon-Fri : 5.10 pm - 10.10 pm & (Sat, Sun & Public holiday : 8.10 am - 5.10 pm)
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Gas oil, petroleum, hydrodesulfurised, light vacuum | 64742-87-6 | 99 - 100% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Consult a medical doctor after significant exposure. If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a medical doctor.
If on skin, rinse well with water. If on clothes, remove clothes. If skin irritation persists, call a medical doctor.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.
Induce vomiting immediately and call a medical doctor. Keep respiratory tract clear. Do NOT give milk or alcoholic beverages. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Take victim immediately to hospital.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
High volume water jet
Do not allow run-off from fire fighting to enter drains or water courses.
Firefighter Protection
Wear self-contained breathing apparatus for firefighting if necessary.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use personal protective equipment. Ensure adequate ventilation.
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains. If the product contaminates rivers and lakes or drains inform respective authorities.
Soak up with inert absorbent material
Materials: sand, silica gel, acid binder, universal binder, sawdust
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid formation of aerosol. Do not breathe vapours/dust. Avoid exposure - obtain special instructions before use. For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Avoid contact with skin and eyes.
Keep container tightly closed in a dry and well-ventilated place. Observe label precautions. Electrical installations / working materials must comply with the technological safety standards. Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Smoking, eating and drinking should be prohibited in the application area.
Normal measures for preventive fire protection.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
The suitability for a specific workplace should be discussed with the producers of the protective gloves.
Eye wash bottle with pure water. Tightly fitting safety goggles.
In the case of vapour formation use a respirator with an approved filter.
Impervious clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Hazardous polymerisation does not occur.
No dangerous reaction known under conditions of normal use.
Strong oxidizing agents.
Fumes, smoke, carbon monoxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Send to a licensed waste management company.
Do not dispose of waste into sewer. Do not contaminate ponds, waterways or ditches with chemical or used container. The product should not be allowed to enter drains, water courses or the soil.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3082
- Shipping Name
- ENVIRONMENTALLY HAZARDOUS SUBSTANCE, LIQUID, N.O.S.
- Transport Class
- 9
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Vacuum Gasoil?
The signal word is danger.
What is the physical form of Vacuum Gasoil?
Vacuum Gasoil is a liquid appearing as liquid with colourless color. It has hydrocarbon-like odor.
What are the hazard statements for Vacuum Gasoil?
This substance has 6 hazard statements:
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H332: Harmful if inhaled.
- H351: Suspected of causing cancer.
- H373: May cause damage to organs (Thymus, Liver, Bone marrow) through prolonged or repeated exposure.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Vacuum Gasoil?
The melting point is No data available and the boiling point is 200 - 800 °C.