Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ISONONANOL
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- 01-2119436678-26-0000
Identified Uses
intermediate, Alcohol components for esterifications.
Manufacturers & Suppliers
Evonik Oxeno GmbH
manufacturer
Postfach, D-45764 Marl
+49 (0)2365/49-6172
Emergency Contacts
Werkfeuerwehr, Infracor GmbH
+49 (0)2365/49-2232
Werkfeuerwehr, Infracor GmbH
+49 (0)2365/49-4423
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| isononyl alcohol EC: 248-471-3 | 27458-94-2 | --- | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move victims into fresh air. If symptoms persist, call a physician. In case of difficulties in breathing, supply oxygen. Employ artificial respiration if breathing ceases. Consult a physician immediately.
Wash off with plenty of water and soap immediately. Continue flushing with polyethylene glycol 400. If symptoms persist, call a physician.
Symptoms: Has skin-degreasing properties.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses if this can be easily done. Protect unharmed eye. See an eye specialist immediately.
Do not induce vomiting and seek medical advice immediately. Clean mouth with water and drink afterwards plenty of water.
Immediate Medical Attention
Consult a physician immediately (inhalation). See an eye specialist immediately (eye). Seek medical advice immediately (ingestion).
Medical Treatment
Symptomatic treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray, foam, CO2, dry powder.
high volume water jet
In case of fire cool endangered containers with water. Closed container may rupture if strongly heated. Heavier than air vapour. Formation of flammable or explosive vapour/air mixtures possible. Keep away from sources of ignition - No smoking.
Firefighter Protection
In the case of respirable dust and/or fumes, use self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Avoid contact with skin, eyes and clothing. Do not inhale vapours / aerosols.
Do not allow entrance in sewage water, drainage systems, stretches of water, soil. Avoid penetration into drainage system or in rooms situated at a lower level because of danger of explosion.
Take up mechanically or with an absorbent material. Fill into marked, sealable containers.
Materials: universal absorbent, diatomaceous earth, oil absorbent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The substance must be handled under strictly controlled conditions according to Article 18 of the REACH regulation: Product is only handled and chemically converted when tightly enclosed within a processing system. Use only trained personnel. Wear personal protective equipment; see section 8. Avoid contact with skin and eyes. Do not inhale vapours / aerosols. Ensure sufficient ventilation. Handle and open container with care.
Keep containers tightly closed in a cool, well-ventilated place.
Normal measures for preventive fire protection. Take precautionary measures against static discharges. Keep away from sources of ignition - No smoking. Ensure explosion proofness.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide for good ventilation if vapours/aerosols are formed.
Chemical-resistant protective gloves (EN 374). Glove material for example, butyl-rubber, Material thickness 0.5 mm, Break through time >= 480 min. Glove material for example, nitrile-butadiene rubber (NBR) gloves, Material thickness 0.35 mm, Break through time >= 480 min. Selection of protective gloves to meet the requirements of specific workplaces. Suitability for specific workplaces should be clarified with protective glove manufacturers.
close-fitting protective goggles (e.g. closed goggles) or face protection
In case of dusts/vapours/aerosols being formed or if the limit values like TLV are exceeded: use respiratory equipment with suitable filter (filter type A) or wear a self contained respiratory apparatus
Select materials and equipment for physical protection depending on the concentration and volume of hazardous substances and the workplace involved.
see section 6.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Reaction with strong oxidants. Vapours may form explosive mixture with air.
Keep away from heat and sources of ignition.
strong oxidizing agents
In case of fire or thermal decomposition production of, for example, Carbon monoxide, carbon dioxide (CO2)
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
waste incineration plant
dispose of to waste incineration plant
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 9003
- Shipping Name
- STOFFE MIT EINEM FLAMMPUNKT ÜBER 60°C UND HÖCHSTENS 100 °C (isononanol)
- Transport Class
- 9
Regulatory Information
Chemical regulations, safety assessments, and compliance status
No substance safety assessment is required for this product because it is an internal local intermediate product and/or a transported intermediate product.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ISONONANOL?
The signal word is danger.
What is the physical form of ISONONANOL?
ISONONANOL is a liquid appearing as colourless, clear with colourless, clear color. It has faint odor.
What is ISONONANOL used for?
intermediate, Alcohol components for esterifications.
What are the hazard statements for ISONONANOL?
This substance has 2 hazard statements:
- H315: Causes skin irritation.
- H318: Causes serious eye damage.
What is the melting point of ISONONANOL?
The melting point is < -75.0 °C and the boiling point is 202.7 °C (1013 hPa).