NextSDS Logo
Safety Data Sheet EN

Di-Potassium Hydrogen Orthophosphate Ph.Eur.

CAS 7758-11-4
EC 231-834-5

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Di-Potassium Hydrogen Orthophosphate Ph.Eur.
Product Code
26932
Chemical Name
Di-Potassium Hydrogen Orthophosphate Ph.Eur.
Synonyms
no data available

Regulatory Identifiers

CAS Number
7758-11-4 Check regulations →
EC Number
231-834-5 Check regulations →

Identified Uses

General chemical reagent

Manufacturers & Suppliers

V

VWR International Ltd.

distributor

Hunter Boulevard, Magna Park Lutterworth, LE17 4XN

0800 22 33 44

Emergency Contacts

CareChem24

+44 (0) 1270 502894

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
di-Potassium hydrogen orthophosphate 7758-11-4 --- No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove casualty to fresh air and keep warm and at rest. If breathing is irregular or stopped, administer artificial respiration. In case of respiratory tract irritation, consult a physician.

Skin contact

After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately. In case of skin reactions, consult a physician.

Eye contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist. Protect uninjured eye. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

If accidentally swallowed rinse the mouth with plenty of water (only if the person is conscious) and obtain immediate medical attention. Do NOT induce vomiting. Give nothing to eat or drink.

Immediate Medical Attention

no data available

Medical Treatment

no data available

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

The product itself does not burn. Co-ordinate fire-fighting measures to the fire surroundings.

Unsuitable media

no restriction

Specific hazards

In case of fire may be liberated: Phosphorus oxides

Instructions

DO NOT fight fire when fire reaches explosives. Use water spray jet to protect personnel and to cool endangered containers.

Firefighter Protection

Wear a self-contained breathing apparatus and chemical protective clothing. Do not inhale explosion and combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Clear spills immediately.

Environmental

Do not allow to enter into surface water or drains.

Cleanup methods

Clean contaminated articles and floor according to the environmental legislation. Collect in closed and suitable containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid: Inhalation Avoid contact with eyes and skin.

Storage

Recommended storage temperature: 15-25°C Keep container tightly closed and in a well-ventilated place.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Technical measures and the application of suitable work processes have priority over personal protection equipment. If handled uncovered, arrangements with local exhaust ventilation have to be used.

Hands

When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits. Recommended glove articles DIN-/EN-Norms: EN ISO 374 In the case of wanting to use the gloves again, clean them before taking off and air them well. By short-term hand contact: Suitable material: NBR (Nitrile rubber) Thickness of the glove material: 0,12 mm Breakthrough time (maximum wearing time): > 480 min Recommended glove articles: VWR 112-0998 By long-term hand contact: Suitable material: NBR (Nitrile rubber) Thickness of the glove material: 0,38 mm Breakthrough time (maximum wearing time): > 480 min Recommended glove articles: VWR 112-3717 / 112-1381

Eyes

Eye glasses with side protection DIN-/EN-Norms: DIN EN 166 Recommendation: VWR 111-0432

Respiratory

Usually no personal respirative protection necessary.

Skin/Body

Wear suitable protective clothing. When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.

Environmental

no data available

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
solid
Softening Point
---
Cloud Point
---
Appearance
solid Colour: white
Vapor Density
no data available
Crystallisation Point
---
Physical State Data
solid
Odor
no data available
Colour
white
Solubility In Fat
---
Melting Point
340 °C
Kinematic Viscosity
no data available
Decomposition Temperature
180 °C
Lower Explosive Limit
no data available
Dynamic Viscosity
no data available
Solidification Point
---
Auto Ignition Temperature
no data available
Voc Content
---
Metal Corrosion
---
Solubility In Water
1,600 g/l (20 °C)
Evaporation Rate
no data available
Relative Evaporation Rate
---
Colour Intensity
---
Odor Threshold
no data available
Molecular Weight
---
Density
---
Ph
8.5-9.6 (50 g/l; H2O; 20 °C)
Partition Coefficient
no data available
Bulk Density
no data available
Explosive Limits
---
Solubility
---
Vapor Pressure
no data available
Flammability
not applicable
Boiling Point
no data available
Flash Point
no data available
Properties Status
---
Upper Explosive Limit
no data available
State Under Standard Conditions
---
Form
---
Freezing Point
---
Relative Density
2.3 g/cm³ (20 °C)
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

no data available

Hazardous reactions

no data available

Avoid

no data available

Incompatible

no data available

Decomposition

no data available

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Dispose according to local legislation. Consult the appropriate local waste disposal expert about waste disposal.

Disposal

Dispose according to local legislation. Consult the appropriate local waste disposal expert about waste disposal.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Di-Potassium Hydrogen Orthophosphate Ph.Eur. known by?

Di-Potassium Hydrogen Orthophosphate Ph.Eur. is also known as: no data available

What is the hazard signal word for Di-Potassium Hydrogen Orthophosphate Ph.Eur.?

The signal word is no signal word.

What is the physical form of Di-Potassium Hydrogen Orthophosphate Ph.Eur.?

Di-Potassium Hydrogen Orthophosphate Ph.Eur. is a solid appearing as solid colour: white with white color. It has no data available odor.

What is Di-Potassium Hydrogen Orthophosphate Ph.Eur. used for?

General chemical reagent

What is the melting point of Di-Potassium Hydrogen Orthophosphate Ph.Eur.?

The melting point is 340 °C and the boiling point is no data available.

Compliance Scanner

Scan your compliance