NextSDS Logo
Aq

Aquilim 315 MV water-based dispersion

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Aquilim 315 MV water-based dispersion
Product Code
450

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Adhesives, sealants

Overview

Aquilim 315 MV water-based dispersion commonly used adhesives, sealants.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (not applicable)

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • not applicable

Precautionary Statements

  • not applicable

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Renia Gesellschaft mbH company logo - Safety Data Sheet supplier organization

Renia Gesellschaft mbH

undefined

πŸ“

Ostmerheimer Straße 516 51109 Kâln

🌍

DE

πŸ“ž

+492216307990

🌐 www.renia.com

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Grimme

πŸ“ž

+49-221-630799-17

🌍

DE

πŸ•’

Only available during office hours.

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

aqueous polychloroprene dispersion

Additional Information

Full text of H- and EUH-statements: see section 16.

Composition Notes

not applicable

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Provide fresh air. If breathing is irregular or stopped, administer artificial respiration. Medical treatment necessary. In case of inhalation of decomposition products, affected person should be moved into fresh air and kept still.

πŸ–οΈ Skin Contact

Take off contaminated clothing and wash it before reuse. After contact with skin, wash immediately with plenty of water and soap.

πŸ‘οΈ Eye Contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.

🍽️ Ingestion/Swallowing

Rinse mouth immediately and drink plenty of water. Do NOT induce vomiting. In case of allergic symptoms, especially in the breathing area, seek medical advice immediately.

🚨 Immediate Medical Attention Required

Medical treatment necessary. Consult an ophthalmologist. In case of allergic symptoms, especially in the breathing area, seek medical advice immediately.

Medical Treatment

Treat symptomatically. Transport affected person in lying position, in case of shortness of breath in half-sitting position. Where appropriate artificial ventilation.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ’¨ Evaporation Rate
not determined
πŸ“Š Auto Ignition Temperature
not applicable
πŸ“Š Odor Threshold
not determined
πŸ“Š Solubility In Fat
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Bulk Density
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Cloud Point
Not available
πŸ“Š Form
Not available
🎨 Colour
whitish
πŸ“Š Relative Density
Not available
πŸ“Š Solidification Point
Not available
πŸ“Š Dynamic Viscosity
1.600 mPas
πŸ‘οΈ Appearance
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Vapor Density
Not available
πŸ“Š Physical State Data
liquid
πŸ“Š Upper Explosive Limit
not applicable
πŸ’¨ Vapor Pressure
23 mbar
πŸ“Š Lower Explosive Limit
not applicable
πŸ“Š State Under Standard Conditions
Not available
πŸ“Š Decomposition Temperature
not determined
πŸ”₯ Flammability
Not available
πŸ“Š Properties Status
Not available
πŸ“Š Crystallisation Point
Not available
πŸ’§ Solubility
Not available
πŸ’¨ Boiling Point
100 Β°C
Critical Property
πŸ”₯ Flash Point
> 500 Β°C
Critical Property
βš–οΈ Density
1 kg/l
Critical Property
πŸ“Š Explosive Limits
Not available
πŸ§ͺ Ph
6 - 9
πŸ“Š Colour Intensity
Not available
πŸ§ͺ Physical State
liquid
Critical Property
πŸ“Š Partition Coefficient
see section 12
πŸ“Š Softening Point
Not available
πŸ“Š Freezing Point
4 Β°C
🧊 Melting Point
4 Β°C
Critical Property
πŸ“Š Solubility In Water
not determined
πŸ“Š Kinematic Viscosity
Not available
πŸ‘ƒ Odor
characteristic

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn.

🧀 Hand Protection

Suitable material: NBR (Nitrile rubber). Thickness of the glove material: >= 0,4 mm. Breakthrough time (maximum wearing time): >= 480 min. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.

πŸ‘οΈ Eye Protection

Wear closely fitting protective glasses in case of splashes.

😷 Respiratory Protection

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn. Combination filtering device (EN 14387). Use the following filter types for cleaning waste gases:

🦺 Skin/Body Protection

When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.

🌍 Environmental Exposure Controls

Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. In case of gas escape or of entry into waterways, soil or drains, inform the responsible authorities.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

βœ… Chemical Stability

The product is stable under storage at normal ambient temperatures.

βš—οΈ Reactivity

No hazardous reaction when handled and stored according to provisions.

⚠️ Hazardous Reactions

No known hazardous reactions.

🚫 Conditions to Avoid

Frost

πŸ§ͺ Incompatible Materials

Acid, concentrated, Alkali (Iye), concentrated, Solvent.

πŸ’¨ Hazardous Decomposition Products

Does not decompose when used for intended uses.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Aquilim 315 MV water-based dispersion?

The signal word for this substance is "no signal word".

What is the physical form of Aquilim 315 MV water-based dispersion?

Aquilim 315 MV water-based dispersion is a liquid with whitish color. It has characteristic odor.

What is Aquilim 315 MV water-based dispersion used for?

Adhesives, sealants

What are the hazard statements for Aquilim 315 MV water-based dispersion?

This substance has 1 hazard statements: not applicable

What is the melting point of Aquilim 315 MV water-based dispersion?

The melting point is 4 Β°C and the boiling point is 100 Β°C.