01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Aquilim 315 MV water-based dispersion
Product Code
450

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Adhesives, sealants

Manufacturers & Suppliers

Renia Gesellschaft mbH logo

Renia Gesellschaft mbH

Ostmerheimer Straße 516, 51109 Köln, Deutschland

+492216307990

http://www.renia.com

Emergency Contacts

Grimme

+49-221-630799-17

Only available during office hours.

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

aqueous polychloroprene dispersion

Full text of H- and EUH-statements: see section 16.

Notes

Full text of H- and EUH-statements: see section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Provide fresh air. If breathing is irregular or stopped, administer artificial respiration. Medical treatment necessary. In case of inhalation of decomposition products, affected person should be moved into fresh air and kept still.

Skin contact

Take off contaminated clothing and wash it before reuse. After contact with skin, wash immediately with plenty of water and soap.

Eye contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.

Ingestion

Rinse mouth immediately and drink plenty of water. Do NOT induce vomiting. In case of allergic symptoms, especially in the breathing area, seek medical advice immediately.

Immediate Medical Attention

Medical treatment necessary. In case of allergic symptoms, especially in the breathing area, seek medical advice immediately.

Medical Treatment

Treat symptomatically. Transport affected person in lying position, in case of shortness of breath in half-sitting position. Where appropriate artificial ventilation.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Carbon dioxide (CO2), alcohol resistant foam, Extinguishing powder, ABC-powder, spray mist, (water), Dry sand.

Unsuitable media

Full water jet. Strong water jet.

Specific hazards

Do not inhale explosion and combustion gases.

Instructions

Remove product from area of fire.

Firefighter Protection

In case of fire: Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with eyes and skin. Use personal protection equipment.

Environmental

Do not allow to enter into surface water or drains. Cover drains.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomaceous earth, acid- or universal binding agents

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use only outdoors or in a well-ventilated area.

Storage

Keep container tightly closed and in a well-ventilated place. Store in a well-ventilated and dry room at temperatures between 10 °C and 30 °C. not useable after freezing.

Hygiene

When using do not eat, drink, smoke, sniff. Draw up and observe skin protection programme. Wash hands and face before breaks and after work and take a shower if necessary.

Fire prevention

No special fire protection measures are necessary.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special measures are necessary.

Hands

Suitable material: NBR (Nitrile rubber); Thickness of the glove material: >= 0,4 mm; Breakthrough time (maximum wearing time): >= 480 min. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves.

Eyes

Wear closely fitting protective glasses in case of splashes.

Respiratory

If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn. Combination filtering device (EN 14387). Use the following filter types for cleaning waste gases:

Skin/Body

When handling with chemical substances, protective clothing with CE-labels including the four control digits must be worn.

Environmental

Do not allow to enter into soil/subsoil. Do not allow to enter into surface water or drains. In case of gas escape or of entry into waterways, soil or drains, inform the responsible authorities.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Density
---
Freezing Point
4 °C
Decomposition Temperature
not determined
Explosive Limits
---
Cloud Point
---
Solubility In Water
not determined
Kinematic Viscosity
---
Appearance
---
Ph
6 - 9
Flash Point
> 500 °C
Boiling Point
100 °C
Crystallisation Point
---
Form
---
Physical State
liquid
Odor
characteristic
Evaporation Rate
not determined
Vapor Pressure
23 mbar
Odor Threshold
not determined
Solubility In Fat
---
Metal Corrosion
---
Bulk Density
---
Solidification Point
---
Voc Content
---
Physical State Data
liquid
Properties Status
---
Solubility
---
Softening Point
---
State Under Standard Conditions
---
Relative Evaporation Rate
---
Density
1 kg/l
Flammability
---
Lower Explosive Limit
not applicable
Colour Intensity
---
Melting Point
4 °C
Molecular Weight
---
Dynamic Viscosity
1.600 mPas
Colour
whitish
Partition Coefficient
see section 12
Auto Ignition Temperature
not applicable
Relative Density
---
Upper Explosive Limit
not applicable
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is stable under storage at normal ambient temperatures.

Reactivity

No hazardous reaction when handled and stored according to provisions.

Hazardous reactions

No known hazardous reactions.

Avoid

Frost

Incompatible

Acid, concentrated, Alkali (lye), concentrated, Solvent.

Decomposition

Does not decompose when used for intended uses.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Do not empty into drains; dispose of this material and its container in a safe way. Waste disposal according to directive 2008/98/EC, covering waste and dangerous waste.

Disposal

Do not empty into drains; dispose of this material and its container in a safe way.

Waste Codes

080416 aqueous liquid waste containing adhesives or sealants other than those mentioned in 08 04 15 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
not applicable
Transport Class
not applicable
Packing Group
not applicable
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Aquilim 315 MV water-based dispersion?

The signal word is no signal word.

What is the physical form of Aquilim 315 MV water-based dispersion?

Aquilim 315 MV water-based dispersion is a liquid with whitish color. It has characteristic odor.

What is Aquilim 315 MV water-based dispersion used for?

Adhesives, sealants

What is the melting point of Aquilim 315 MV water-based dispersion?

The melting point is 4 °C and the boiling point is 100 °C.