NextSDS Logo
LO

LOCTITE 2701

NO SIGNAL WORD SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
LOCTITE 2701

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Anaerobic Adhesive

Overview

LOCTITE 2701 is a liquid green substance commonly used anaerobic adhesive.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Sensitizing
Xi - Irritant

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Limited

undefined

๐Ÿ“

Apollo Court, 2 Bishop Square Business Park AL10 9EY Hatfield Great Britain

๐ŸŒ

GB

๐Ÿ“ž

+44 (1707) 635000

๐Ÿ“ 

+44 (1707) 635099

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+44 (0)1442 278497

๐ŸŒ

GB

๐Ÿ•’

24 Hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Anaerobic adhesive

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Cumene hydroperoxide
EC: 201-254-7
80-15-9 1-2.5% โš ๏ธ Hazardous
2-Hydroxyethyl methacrylate
EC: 212-782-2
868-77-9 0.1-1% โš ๏ธ Hazardous
Cumene
EC: 202-704-5
98-82-8 2.5% โš ๏ธ Hazardous
Hydroxypropyl methacrylate
EC: 248-666-3
27813-02-1 25-50% โš ๏ธ Hazardous
Methacryloyloxyethyl succinate
EC: 244-096-4
20882-04-6 1-5% โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Move to fresh air. If symptoms persist, seek medical advice.

Symptoms:

Irritation, coughing, shortness of breath, chest tightness.

๐Ÿ–๏ธ Skin Contact

Rinse with running water and soap. Seek medical advice.

Symptoms:

Rash, Urticaria.

๐Ÿ‘๏ธ Eye Contact

Rinse immediately with plenty of running water (for 10 minutes). Seek medical attention if necessary.

Symptoms:

Irritation, conjunctivitis.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth, drink 1-2 glasses of water, do not induce vomiting. Seek medical advice.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid green
๐ŸŽจ Colour
green
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
liquid
๐Ÿ‘ƒ Odor
Mild
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
Not available
๐Ÿ’จ Boiling Point
> 149,0 C (> 300.2 F)
Critical Property
๐Ÿ”ฅ Flash Point
>100 (> 212 F)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
0,3000000 mbar
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,1 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not available
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Partially soluble (Solvent: Water); Miscible (Solvent: Acetone); emulsifiable (Solvent: Water)
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
Partially soluble; emulsifiable
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Use only in well-ventilated areas.

๐Ÿงค Hand Protection

Avoid skin-contact. Chemical-resistant protective gloves (EN 374). Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time as per EN 374): nitrile rubber (NBR; >= 0.4 mm thickness) This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g. temperature). If signs of wear and tear are noticed then the gloves should be replaced.

๐Ÿ‘๏ธ Eye Protection

Wear protective glasses.

๐Ÿ˜ท Respiratory Protection

An approved mask or respirator fitted with an organic vapour cartridge should be worn if the product is used in a poorly ventilated area Filter type: A

๐Ÿฆบ Skin/Body Protection

Wear suitable protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LOCTITE 2701?

The signal word for this substance is "no signal word".

What is the solubility of LOCTITE 2701?

Partially soluble (Solvent: Water); Miscible (Solvent: Acetone); emulsifiable (Solvent: Water)

What is LOCTITE 2701 used for?

Anaerobic Adhesive