NextSDS Logo
Safety Data Sheet EN

Gutta à l'eau incolore / colourless

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Gutta à l'eau incolore / colourless
Product Code
115000

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Paints & Varnishes for artists

Manufacturers & Suppliers

PEBEO S A. logo

PEBEO S A.

manufacturer

305 AVENUE DU PIC DE BERTAGNE - BP106 -.13881.GEMENOS CEDEX.FRANCE

33 (0) 4.42.32.08.08.

http://www.pebeo.com

Emergency Contacts

INRS / ORFILA

33 (0) 1.45.42.59.59

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

No substances fulfil the criteria set forth in annexe II section A of the REACH regulation (EC) n° 1907/2006.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Eye contact

Wash thoroughly with soft, clean water for 15 minutes holding the eyelids open.

Ingestion

In the event of swallowing, if the quantity is small (no more than one mouthful), rinse the mouth with water and consult a doctor. Do not force vomiting.

Immediate Medical Attention

Seek medical attention, showing the label. If swallowed accidentally, call a doctor to ascertain whether observation and hospital care will be necessary. Show the label.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

sprayed water or water mist, foam, multipurpose ABC powder, BC powder, carbon dioxide (CO2)

Unsuitable media

water jet

Specific hazards

A fire will often produce a thick black smoke. Exposure to decomposition products may be hazardous to health. Do not breathe in smoke.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Consult the safety measures listed under headings 7 and 8.

Environmental

Contain and control the leaks or spills with non-combustible absorbent materials such as sand, earth, vermiculite, diatomaceous earth in drums for waste disposal. Prevent any material from entering drains or waterways.

Cleanup methods

Clean preferably with a detergent, do not use solvents.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Always wash hands after handling. Ensure that there is adequate ventilation, especially in confined areas. Handle in well-ventilated areas. Prevent access by unauthorised personnel. Observe precautions stated on label and also industrial safety regulations. Packages which have been opened must be reclosed carefully and stored in an upright position.

Storage

Packages which have been opened must be reclosed carefully and stored in an upright position.

Hygiene

Always wash hands after handling. No smoking, eating or drinking in areas where the mixture is used.

Fire prevention

Handle in well-ventilated areas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure that there is adequate ventilation, especially in confined areas.

Hands

Wear suitable protective gloves in the event of prolonged or repeated skin contact. Type of gloves recommended : - Natural latex - Nitrile rubber (butadiene-acrylonitrile copolymer rubber (NBR)) - PVC (polyvinyl chloride) - Butyl Rubber (Isobutylene-isoprene copolymer)

Eyes

Avoid contact with eyes. Use eye protectors designed to protect against liquid splashes Before handling, wear safety goggles in accordance with standard EN166.

Skin/Body

Work clothing worn by personnel shall be laundered regularly. After contact with the product, all parts of the body that have been soiled must be washed.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Viscous liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
---
Colour Intensity
---
Form
---
Odor
---
Odor Threshold
---
Ph
8.00
Melting Point
Not relevant.
Boiling Point
Not relevant.
Flash Point
Not relevant.
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
Not relevant.
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
1.02
Flammability
---
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
Not relevant.
Decomposition Temperature
Not relevant.
Solubility
---
Partition Coefficient
---
Solubility In Water
Dilutable.
Solubility In Fat
---
Molecular Weight
---
Voc Content
29.10 g/l
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This mixture is stable under the recommended handling and storage conditions in section 7.

Reactivity

No data available.

Avoid

high temperatures

Decomposition

carbon monoxide and dioxide, fumes and nitrogen oxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1. Toxicity

### 12.1.2. Mixtures No aquatic toxicity data available for the mixture.

No aquatic toxicity data available for the mixture.

12.2. Persistence and degradability

No data available.

12.3. Bioaccumulative potential

No data available.

No data available.

12.4. Mobility in soil

No data available.

12.5. Results of PBT and vPvB assessment

No data available.

No data available.

12.6. Other adverse effects

No data available.

No data available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Do not pour into drains or waterways. Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company.

Disposal

Recycle or dispose of waste in compliance with current legislation, preferably via a certified collector or company.

Waste Codes

20 01 27 * paint, inks, adhesives and resins containing dangerous substances EWC
15 01 02 plastic packaging EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Classification and labelling information included in section 2.

Chemical Safety Assessment Not performed

Made under licence of European Label System® MSDS software from InfoDyne - http://www.infodyne.fr

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Gutta à l'eau incolore / colourless?

The signal word is no signal word.

What is the physical form of Gutta à l'eau incolore / colourless?

Gutta à l'eau incolore / colourless is a viscous liquid. .

What is Gutta à l'eau incolore / colourless used for?

Paints & Varnishes for artists

What is the melting point of Gutta à l'eau incolore / colourless?

The melting point is Not relevant. and the boiling point is Not relevant..