Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- FPG50030W_S25BCP_FRIT
- Product Form
- solid
- Product Code
- 000000000010000376
- Chemical Name
- fritten, chemicaliën (bevat lood)
- Synonyms
- FPG50030W
Regulatory Identifiers
- CAS Number
- 65997-18-4 Check regulations →
- EC Number
- 266-047-6 Check regulations →
- REACH No.
- 01-2119548361-42-0006
Identified Uses
Application via ink jet in the production of ceramics and glass Manufacture of metallic products Manufacture of non-metallic products (e.g. ceramics) Formulation or re-packaging Use of frits as intermediate in the manufacture of glass
Manufacturers & Suppliers
COLOROBBIA ITALIA S.P.A.
manufacturer
Indirizzo via Pietramarina 53 Località e Stato 50053 Sovigliana - Vinci (FI) Italia
+39 0571 7091
Emergency Contacts
CAV - Ospedale Pediatrico Bambino Gesù - Roma
+39 06 68593726
Az. Ospedaliera Università Foggia - Foggia
800183459
Az. Ospedaliera - A. Cardarelli- Napoli
+39 081 7472870
CAV - Policlinico Umberto I- Roma
+39 06 49978000
CAV - Policlinico A. Gemelli - Roma
+39 06 3054343
Az. Ospedaliera Careggi - U.O. Tossicologia Medica - Firenze
+39 055 7947819
CAV - Centro Nazionale di Informazione Tossicologica - Pavia
+39 0382 24444
Ospedale Niguarda Ca' Granda - Milano
+39 02 66101029
Az. ospedaliera Papa Giovanni XXIII - Bergamo
800883300
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
There are no additional ingredients present which, within the current knowledge of the supplier, are classified and contribute to the classification of the substance and hence require reporting in this section.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Frits, chemicals EC: 266-047-6 | 65997-18-4 | 100% | No |
For additional compositional information, please see section 16.
Notes
This frit fulfil the requirements established in Annex V, point 11 to Regulation 1907/2006 related to the exemptions from registration.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.
Symptoms: No specific data.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.
Symptoms: No specific data.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.
Symptoms: No specific data.
Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.
Symptoms: No specific data.
Immediate Medical Attention
Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled. No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use an extinguishing agent suitable for the surrounding fire.
None known.
No specific fire or explosion hazard.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode. Clothing for fire-fighters (including helmets, protective boots and gloves) conforming to European standard EN 469 will provide a basic level of protection for chemical incidents.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Put on appropriate personal protective equipment.
Move containers from spill area. Vacuum or sweep up material and place in a designated, labeled waste container. Dispose of via a licensed waste disposal contractor.
Move containers from spill area. Prevent entry into sewers, water courses, basements or confined areas. Vacuum or sweep up material and place in a designated, labeled waste container. Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
Vacuum or sweep up material and place in a designated, labeled waste container.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8).
Store in accordance with local regulations. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas. See also Section 8 for additional information on hygiene measures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
If prolonged contact with the product is expected, it is advisable to protect hands with work gloves resistant to penetration (ref. Standard EN 374). For the final choice of the material of the work gloves, it is also necessary to evaluate the process of use of the product and any other resulting products. It should also be remembered that latex gloves can give rise to sensitization phenomena.
It is recommended to wear airtight protective goggles (ref. Standard EN 166).
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
No specific data.
No specific data.
Under normal conditions of storage and use, hazardous decomposition products should not be produced.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements. Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- Shipping Name
- Not regulated.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What other names is FPG50030W_S25BCP_FRIT known by?
FPG50030W_S25BCP_FRIT is also known as: FPG50030W
What is the hazard signal word for FPG50030W_S25BCP_FRIT?
The signal word is no signal word.
What is the physical form of FPG50030W_S25BCP_FRIT?
FPG50030W_S25BCP_FRIT is a solid [solid beads.] appearing as solid [solid beads.] with various color. It has odorless. odor.
What is FPG50030W_S25BCP_FRIT used for?
Application via ink jet in the production of ceramics and glass Manufacture of metallic products Manufacture of non-metallic products (e.g. ceramics) Formulation or re-packaging Use of frits as intermediate in the manufacture of glass
What is the melting point of FPG50030W_S25BCP_FRIT?
The melting point is Not available. and the boiling point is Not available..