NextSDS Logo
Safety Data Sheet EN

Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV
Synonyms
None.

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Non-Setting and Non-Hardening Gasketing Compound.

Uses advised against

None known.

Manufacturers & Suppliers

H

Hylomar Ltd.

manufacturer

Hylo House, Cale Lane, New Springs, Wigan, Greater Manchester, UK, WN2 1JT

+44(0)1942 617000

Emergency Contacts

Emergency Contact

1-760-476-3961

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Hazard Statements

The mixture does not meet the criteria for classification.

Precautionary Statements

P281 Use personal protective equipment as required.
P314 Get medical advice/attention if you feel unwell.
Store away from incompatible materials.
Dispose of waste and residues in accordance with local authority requirements.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The components are not hazardous or are below required disclosure limits.

Notes

The components are not hazardous or are below required disclosure limits.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing. Call a physician if symptoms develop or persist.

Skin contact

Wash off with soap and water. Get medical attention if irritation develops and persists.

Eye contact

Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately.

Symptoms: Direct contact with eyes may cause temporary irritation.

Ingestion

Rinse mouth. Drink a few glasses of water or milk. Get medical attention if any discomfort continues.

Immediate Medical Attention

Get medical attention immediately.

Medical Treatment

Provide general supportive measures and treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray, foam, dry powder or carbon dioxide.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

By heating and fire, toxic vapours/gases may be formed.

Instructions

Cool containers exposed to heat with water spray and remove container, if no risk is involved.

Firefighter Protection

Self-contained breathing apparatus and full protective clothing must be worn in case of fire. Selection of respiratory protection for firefighting: follow the general fire precautions indicated in the workplace.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Avoid contact with skin and eyes. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unnecessary personnel away.

Environmental

Prevent further leakage or spillage if safe to do so. Do not discharge into drains, water courses or onto the ground.

Cleanup methods

Scrape up the spilled material. Transfer to a container for disposal. Following product recovery, flush area with water.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from sources of ignition - No smoking. Wear protective clothing as described in Section 8 of this safety data sheet. Avoid prolonged exposure. Wash thoroughly after handling. Wash contaminated clothing before reuse. Observe good industrial hygiene practices. Avoid release to the environment. Avoid contact with skin and eyes.

Storage

Keep container tightly closed in a cool, well-ventilated place. Keep away from heat, spark, open flames and other sources of ignition. Store away from incompatible materials. Store in a cool, dark place at temperatures between 5°C and 35°C.

Hygiene

Wash thoroughly after handling. Wash contaminated clothing before reuse. Observe good industrial hygiene practices.

Fire prevention

Keep away from sources of ignition - No smoking. Keep away from heat, spark, open flames and other sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide adequate ventilation.

Hands

Wear protective gloves. PVC or rubber gloves are recommended. Be aware that the liquid may penetrate the gloves. Frequent change is advisable. Suitable gloves can be recommended by the glove supplier.

Eyes

If eye contact is likely, safety glasses with side shields or chemical type goggles should be worn.

Respiratory

Under normal conditions, respirator is not normally required. If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn.

Skin/Body

Normal work clothing (long sleeved shirts and long pants) is recommended.

Environmental

Environmental manager must be informed of all major releases.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Ph
Not available.
Softening Point
---
State Under Standard Conditions
---
Relative Evaporation Rate
---
Cloud Point
---
Physical State
Liquid.
Solubility In Water
---
Vapor Density
2 (Air = 1) (20 °C/68 °F)
Boiling Point
Not applicable.
Metal Corrosion
---
Appearance
Blue paste.
Dynamic Viscosity
275000 cP (Hylomar Advanced Formulation) (25 °C/77 °F); 1000000 cP (Hylomar Advanced Formulation HV) (25 °C/77 °F); 1500000 cP (Hylomar Advanced Form Ultra HV) (25 °C/77 °F)
Odor
Almost odorless.
Solubility In Fat
---
Freezing Point
Not available.
Upper Explosive Limit
Not available.
Auto Ignition Temperature
Not available.
Flash Point
> 392.0 °C (> 737.6 °F)
Form
Paste.
Voc Content
0 (Hylomar Test Method 1.1A Determination of Volatile Matter)
Colour Intensity
---
Flammability
Not available.
Properties Status
---
Lower Explosive Limit
Not available.
Odor Threshold
Not available.
Vapor Pressure
Not available.
Explosive Limits
---
Physical State Data
liquid
Melting Point
Not available.
Partition Coefficient
Not available.
Decomposition Temperature
Not available.
Relative Density
1.18 (20 °C/68 °F)
Density
---
Evaporation Rate
Not available.
Kinematic Viscosity
---
Bulk Density
---
Molecular Weight
---
Colour
Blue.
Solubility
Not miscible.
Crystallisation Point
---
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is stable and non reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Heat, flames and sparks. Avoid temperatures exceeding the flash point.

Incompatible

Strong oxidising agents. Strong alkalis.

Decomposition

Thermal decomposition or combustion may liberate carbon oxides and other toxic gases or vapours. Hydrogen cyanide. Carbon monoxide. Carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Collect and reclaim or dispose in sealed containers at licensed waste disposal site.

Disposal

Do not discharge into rivers, lakes, mountains, etc. because the product may affect the environment. Collect and reclaim or dispose in sealed containers at licensed waste disposal site.

Waste Codes

The Waste code should be assigned in discussion between the user, the producer and the waste disposal company. EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The product is classified and labelled in accordance with EC directives or respective national laws. This Safety Data Sheet complies with the requirements of Regulation (EC) No 1907/2006.

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What other names is Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV known by?

Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV is also known as: None.

What is the hazard signal word for Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV?

The signal word is no signal word.

What is the physical form of Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV?

Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV is a liquid. appearing as blue paste. with blue. color. It has almost odorless. odor.

What is the solubility of Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV?

Not miscible.

What is Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV used for?

Non-Setting and Non-Hardening Gasketing Compound.

What are the hazard statements for Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV?

This substance has 1 hazard statement:

  • The mixture does not meet the criteria for classification.

What is the melting point of Hylomar Advanced Formulation / Hylomar Advanced Formulation HV / Hylomar Advanced Form Ultra HV?

The melting point is Not available. and the boiling point is Not applicable..