Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh
- Product Code
- 2624050155
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
/
Manufacturers & Suppliers
KERN & SOHN GmbH
manufacturer
Ziegelei 1, 72336 Balingen
Emergency Contacts
Emergency Contact
86-13401408613
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
Product name: Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Nickel-cobalt manganese lithium EC: 620-032-4 | 346417-97-8 | 36.6% | No |
| Grabite EC: 231-955-3 | 7782-42-5 | 19.8% | No |
| Iron EC: 231-096-4 | 7439-89-6 | 17.3% | No |
| Copper EC: 231-159-6 | 7440-50-8 | 7.6% | No |
| Dimethyl carbonate EC: 210-478-4 | 616-38-6 | 6.8% | No |
| Aluminum EC: 231-072-3 | 7429-90-5 | 3.5% | No |
| Lithium hexafluorophosphate EC: 244-334-7 | 21324-40-3 | 2% | No |
| Ethylene carbonate EC: 202-510-0 | 96-49-1 | 2% | No |
| Ethyl methyl carbonate EC: 613-014-2 | 623-53-0 | 1% | No |
| Acetylene black EC: 215-609-9 | 1333-86-4 | 0.9% | No |
| PP EC: 618-352-4 | 9003-07-0 | 0.7% | No |
| Nickel EC: 231-111-4 | 7440-02-0 | 0.7% | No |
| PVDF EC: 607-458-6 | 24937-79-9 | 0.4% | No |
| Styrene-butadiene rubber EC: 618-370-2 | 9003-55-8 | 0.4% | No |
| CMC EC: 618-326-2 | 9000-11-7 | 0.3% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately remove to fresh air. If breathing is difficult, give oxygen. If not breathing, give artificial respiration. Call a physician.
Remove the contaminated clothing and footwear, immediately flush with plenty of water for at least 20 minutes. If irritation persists, call a physician.
Lift your eyelids immediately and rinse them with running water for more than 20 minutes. If irritation persists, call a physician.
Do not induce vomiting. Call a physician immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray or regular foam.
May decompose upon combustion to generate irritating, corrosive or toxic fumes. Fumes may cause dizziness or suffocation.
Fire-extinguishing work is done from the windward.
Firefighter Protection
Wear self-contained breathing apparatus and protective clothing to prevent contact with skin and eyes.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep people away from and upwind of spill/leak. Entry to noninvolved personnel should be controlled around the leakage area by roping off.
Avoid directly release the cleaning waste water into the environment.
The leaked batteries and dirty adsorbents should be placed in metal containers.
Related Products
Similar products with comparable safety profiles
Lithium ion battery ICR18650HE2
---
Lithium-ion Polymer Battery SDL-857080 11.1V 4000mAh 44.4Wh
---
Lithium-Ion Rechargeable Battery Pack BL1860B
---
Li-ion Battery Pack
---
Li-SOCl₂ Cylindrical Battery ER14505 3.6V 2600mAh
---
Lithium-Ion Rechargeable Battery Pack BL3626
---
Lithium-Ion Rechargeable Battery Pack BL1820B
---
Lithium-Ion Rechargeable Battery Pack BL1820B
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Operators should be trained and strictly abide by operating procedures. Wear appropriate protective clothing and safety gloves. Keep away from ignition sources, heat and flame. No smoking at working site. Handling is performed in a well ventilated place. Avoid disassembling the battery at will and reversing battery polarity within the battery assembly. Such batteries must be packed in inner packaging in such a manner as to effectively prevent short circuits and to prevent movement which could lead to short circuits. In case of leakage of the material in the battery, avoid directly contact with eyes and skin. Avoid inhalation.
Store in a cool, dry, and well-ventilated area. Keep away from ignition sources, heat and flame. Storage place should be equipped with appropriate varieties and quantities of fire fighting equipment and leakage emergency treatment equipment.
Operators should be trained and strictly abide by operating procedures. Wear appropriate protective clothing and safety gloves. No smoking at working site.
Keep away from ignition sources, heat and flame.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Mechanical exhaust required. Safety shower and eye bath.
Wear safety gloves.
Wear chemical safety glasses if needed.
Wear government approved respirator if needed.
Wear appropriate protective clothing.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal temperatures and pressures.
No data available.
No data available.
Avoid misoperation, exposure to heat and open flame. Avoid mechanical or electrical abuse and overcharge. Prevent short circuits. Prevent movement which could lead to short circuits.
Strong oxidizing agents, Combustible materials and Corrosives.
Carbon oxides, metal oxides, etc.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Contact a licensed professional waste disposal service to dispose of wastes.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN3480
- Shipping Name
- Lithium ion batteries
- Transport Class
- 9
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh?
The signal word is no signal word.
What is the physical form of Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh?
Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh is a solid appearing as blue plastic film shell with blue color. It has odorless odor.
What is the solubility of Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh?
Partial soluble in water
What is Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh used for?
/
What is the melting point of Li-ion Battery 18650 2S1P 7.4V 2600mAh 19.24Wh?
The melting point is >300°C and the boiling point is No data available.