Basic Product Information

Product Name
Wash Buffer 3

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Product for analytical use

Overview

Wash Buffer 3 commonly used product for analytical use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapor.

Precautionary Statements

  • Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
  • Keep container tightly closed.
  • Ground/bond container and receiving equipment.
  • Use explosion-proof electrical/ventilating/lighting/equipment.
  • Use only non-sparking tools.
  • Take precautionary measures against static discharge.
  • Wear protective gloves/protective clothing/eye protection/face protection.
  • If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • Store in a well-ventilated place. Keep cool.
  • Dispose of contents/container in accordance with local/regional/national/international regulations.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Revvity chemagen Technologie GmbH

manufacturer

Arnold-Sommerfeld-Ring 2 52499 BAESWEILER DEUTSCHLAND

DE

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

800 424-9300

US

within U.S.

CHEMTREC

+1-703-672-3887

US

from outside U.S

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Mixture of the substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
ALCOHOL
EC: 200-578-6
64-17-5 20-40% Hazardous
sodium perchlorate
EC: 231-511-9
7601-89-0 10-20% Hazardous
water, distilled, conductivity or of similar purity
EC: 231-791-2
7732-18-5 40-60% Non-hazardous
sodium acetate
EC: 204-823-8
127-09-3 1-3% Non-hazardous
Polyoxyethylenesorbitan monolaurate
EC: 500-018-3
9005-64-5 0.75-1.5% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

Skin Contact

Immediately rinse with water.

Eye Contact

Rinse opened eye for several minutes under running water.

Ingestion/Swallowing

If symptoms persist consult doctor.

Immediate Medical Attention Required

No further relevant information available.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Relative Evaporation Rate
Not available
Partition Coefficient
Not determined.
Evaporation Rate
Not determined.
Physical State
Fluid
Critical Property
Properties Status
Not available
Decomposition Temperature
Not determined.
Cloud Point
Not available
Explosive Limits
Not available
Molecular Weight
Not available
State Under Standard Conditions
Not available
Vapor Density
Not determined.
Colour
According to product specification
Form
Fluid
Flash Point
27 C (80.6 F)
Critical Property
Melting Point
Undetermined.
Critical Property
Voc Content
20 - 40 %
Auto Ignition Temperature
425 C (797 F)
Solidification Point
Not available
Colour Intensity
Not available
Flammability
Flammable.
Density
1.05 g/cm (8.76225 lbs/gal)
Critical Property
Crystallisation Point
Not available
Physical State Data
liquid
Solubility
Not available
Solubility In Fat
Not available
Softening Point
Not available
Odor
Characteristic
Freezing Point
Not available
Kinematic Viscosity
Not determined.
Boiling Point
78 C (172.4 F)
Critical Property
Ph
5.4
Odor Threshold
Not determined.
Appearance
Not available
Vapor Pressure
59 hPa (44.3 mm Hg)
Lower Explosive Limit
Not determined.
Bulk Density
Not available
Relative Density
Not determined.
Metal Corrosion
Not available
Solubility In Water
Fully miscible.
Dynamic Viscosity
Not determined.
Upper Explosive Limit
Not determined.
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eye Protection

Tightly sealed goggles

Respiratory Protection

Not required.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1170

Proper Shipping Name

ETHANOL (ETHYL ALCOHOL) SOLUTION

Transport Hazard Class

3 Flammable liquids

Packing Group

III

IMDG Maritime Transport Precautions

Warning: Flammable liquids

IATA Air Transport Precautions

Warning: Flammable liquids

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Wash Buffer 3?

The signal word for this substance is "warning".

What is the physical form of Wash Buffer 3?

Wash Buffer 3 is a fluid with according to product specification color. It has characteristic odor.

What is Wash Buffer 3 used for?

Product for analytical use

What are the hazard statements for Wash Buffer 3?

This substance has 1 hazard statements: H226: Flammable liquid and vapor.

What is the melting point of Wash Buffer 3?