NextSDS Logo
Wa

Wash Buffer 3

WARNING Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Wash Buffer 3

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Product for analytical use

Overview

Wash Buffer 3 commonly used product for analytical use.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Flam. Liq. Category 3 H226

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Flammable liquid and vapor.

Precautionary Statements

  • Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
  • Keep container tightly closed.
  • Ground/bond container and receiving equipment.
  • Use explosion-proof electrical/ventilating/lighting/equipment.
  • Use only non-sparking tools.
  • Take precautionary measures against static discharge.
  • Wear protective gloves/protective clothing/eye protection/face protection.
  • If on skin (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
  • Store in a well-ventilated place. Keep cool.
  • Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Revvity chemagen Technologie GmbH

manufacturer

๐Ÿ“

Arnold-Sommerfeld-Ring 2 52499 BAESWEILER DEUTSCHLAND

๐ŸŒ

DE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

CHEMTREC

๐Ÿ“ž

800 424-9300

๐ŸŒ

US

๐Ÿ’ก

within U.S.

CHEMTREC

๐Ÿ“ž

+1-703-672-3887

๐ŸŒ

US

๐Ÿ’ก

from outside U.S

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Mixture of the substances listed below with nonhazardous additions.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
ALCOHOL
EC: 200-578-6
64-17-5 20-40% โš ๏ธ Hazardous
sodium perchlorate
EC: 231-511-9
7601-89-0 10-20% โš ๏ธ Hazardous
water, distilled, conductivity or of similar purity
EC: 231-791-2
7732-18-5 40-60% โœ“ Non-hazardous
sodium acetate
EC: 204-823-8
127-09-3 1-3% โœ“ Non-hazardous
Polyoxyethylenesorbitan monolaurate
EC: 500-018-3
9005-64-5 0.75-1.5% โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately rinse with water.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water.

๐Ÿฝ๏ธ Ingestion/Swallowing

If symptoms persist consult doctor.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
According to product specification
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
5.4
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
78 C (172.4 F)
Critical Property
๐Ÿ”ฅ Flash Point
27 C (80.6 F)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
59 hPa (44.3 mm Hg)
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.05 g/cm (8.76225 lbs/gal)
Critical Property
๐Ÿ”ฅ Flammability
Flammable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
425 C (797 F)
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Fully miscible.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
20 - 40 %
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

๐Ÿ‘๏ธ Eye Protection

Tightly sealed goggles

๐Ÿ˜ท Respiratory Protection

Not required.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN1170

๐Ÿ“ฆ Proper Shipping Name

ETHANOL (ETHYL ALCOHOL) SOLUTION

โš ๏ธ Transport Hazard Class

3 Flammable liquids

๐Ÿ“‹ Packing Group

III

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Flammable liquids

โœˆ๏ธ IATA Air Transport Precautions

Warning: Flammable liquids

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Wash Buffer 3?

The signal word for this substance is "warning".

What is the physical form of Wash Buffer 3?

Wash Buffer 3 is a fluid with according to product specification color. It has characteristic odor.

What is Wash Buffer 3 used for?

Product for analytical use

What are the hazard statements for Wash Buffer 3?

This substance has 1 hazard statements: H226: Flammable liquid and vapor.

What is the melting point of Wash Buffer 3?

The melting point is Undetermined. and the boiling point is 78 C (172.4 F).