NextSDS Logo
Safety Data Sheet EN

Sodium acetate

CAS 127-09-3

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Sodium acetate
Product Code
241245

Regulatory Identifiers

CAS Number
127-09-3 Check regulations →

Identified Uses

Laboratory chemicals, Synthesis of substances

Uses advised against

The product is being supplied under the TSCA R&D Exemption (40 CFR Section 720.36). It is the recipient's responsibility to comply with the requirements of the R&D exemption. The product may not be used for a non-exempt commercial purpose under TSCA unless appropriate consent is granted in writing by MilliporeSigma.

Manufacturers & Suppliers

S

Sigma-Aldrich Inc.

manufacturer

3050 SPRUCE ST, ST. LOUIS MO 63103, UNITED STATES

+1 314 771-5765

Emergency Contacts

CHEMTREC (USA)

800-424-9300

24 Hours/day; 7 Days/week

CHEMTREC (International)

+1-703-527-3887

24 Hours/day; 7 Days/week

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance
Chemical Name CAS Number Concentration Hazardous
Acetic acid sodium salt EC: 204-823-8 127-09-3 --- No

Notes

No components need to be disclosed according to the applicable regulations.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

After inhalation: fresh air.

Skin contact

In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower.

Eye contact

After eye contact: rinse out with plenty of water. Remove contact lenses.

Ingestion

After swallowing: make victim drink water (two glasses at most). Consult doctor if feeling unwell.

Immediate Medical Attention

Consult doctor if feeling unwell.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water, Foam, Carbon dioxide (CO2), Dry powder

Unsuitable media

For this substance/mixture no limitations of extinguishing agents are given.

Specific hazards

Carbon oxides, Sodium oxides, Combustible. Development of hazardous combustion gases or vapours possible in the event of fire.

Instructions

Suppress (knock down) gases/vapors/mists with a water spray jet.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate the danger area, observe emergency procedures, consult an expert.

Cleanup methods

Take up dry.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For precautions see section 2.2.

Storage

Tightly closed. Dry. Handle and store under inert gas.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Full contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L. Splash contact: Material: Nitrile rubber, Minimum layer thickness: 0.11 mm, Break through time: 480 min, Material tested: KCL 741 Dermatril® L.

Eyes

Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses

Respiratory

Recommended Filter type: Filter type P1. Required when dusts are generated. Standards: DIN EN 143, DIN 14387.

Environmental

Do not let product enter drains.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Explosive Limits
---
Physical State Data
solid
Vapor Density
No data available
Form
solid
Flammability
No data available
Boiling Point
No data available
Density
1.528 g/cm3
State Under Standard Conditions
---
Melting Point
> 300 °C (> 572 °F)
Colour Intensity
---
Relative Density
No data available
Physical State
solid
Colour
white
Metal Corrosion
---
Partition Coefficient
No data available
Solubility
---
Ph
No data available
Voc Content
---
Evaporation Rate
No data available
Dynamic Viscosity
---
Auto Ignition Temperature
No data available
Flash Point
No data available
Kinematic Viscosity
---
Cloud Point
---
Odor
No data available
Freezing Point
No data available
Crystallisation Point
---
Bulk Density
---
Properties Status
---
Relative Evaporation Rate
---
Upper Explosive Limit
No data available
Vapor Pressure
No data available
Softening Point
---
Decomposition Temperature
No data available
Solubility In Water
No data available
Solubility In Fat
---
Solidification Point
---
Appearance
solid, white
Lower Explosive Limit
No data available
Odor Threshold
No data available
Molecular Weight
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

The product is chemically stable under standard ambient conditions (room temperature).

Reactivity

The following applies in general to flammable organic substances and mixtures: in correspondingly fine distribution, when whirled up a dust explosion potential may generally be assumed.

Hazardous reactions

Risk of explosion with: nitrates Exothermic reaction with: Fluorine

Avoid

Exposure to moisture. no information available

Incompatible

No data available

Decomposition

In the event of fire: see section 5

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Waste material must be disposed of in accordance with the national and local regulations.

Disposal

Leave chemicals in original containers. No mixing with other waste.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Sodium acetate?

The signal word is no signal word.

What is the physical form of Sodium acetate?

Sodium acetate is a solid appearing as solid, white with white color. It has no data available odor.

What is Sodium acetate used for?

Laboratory chemicals, Synthesis of substances

What is the melting point of Sodium acetate?

The melting point is > 300 °C (> 572 °F) and the boiling point is No data available.