Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- INOX CLEAN
- Product Code
- Clean
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Neutralizer for stainless steel
Manufacturers & Suppliers
NITTY-GRITTY S.R.L.
manufacturer
VIA DEI MARMORARI 36, 41057 SPILAMBERTO ITALIA
+39059785210
Emergency Contacts
Emergency Contact
+393385767602
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| SODIUM PHOSPHATE TRIBASIC ANHYDROUS EC: 231-509-8 | 7601-54-9 | 4 - 4.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Immediately seek medical advice. In the meantime, remove the patient to open air, far from the contaminated premises; if respiration stops or is difficult, give an artificial respiration adopting the proper measure for the helper.
Immediately take off all contaminated clothing and have a shower. Seek medical advice.
Wash immediately with plenty of water for at least 15 minutes and seek medical advice at once.
Have the patient drink water as much as possible and seek medical advice immediately. Do not induce vomiting before consulting a doctor.
Immediate Medical Attention
Seek medical advice at once/immediately.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The extinction equipment should be of the conventional kind: carbon dioxide, foam, powder and nebulised water.
None in particular.
Do not breathe combustion products (carbon oxide, toxic pyrolysis products, etc).
Use jets of water to cool the containers to prevent product decomposition and the development of substances potentially hazardous for health.
Firefighter Protection
Always wear full fire prevention gear.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Eliminate all sources of ignition (cigarettes, flames, sparks, etc.) from the leakage site. If there are no contraindications, spray solid products with water to prevent the formation of dust. Use breathing equipment if fumes or powders are released into the air. Block the leakage if there is no hazard. Do not handle damaged containers or the leaked product before donning appropriate protective gear.
The product must not penetrate the sewers, surface water, ground water and neighbouring areas.
Use inert absorbent material to soak up leaked product. Collect the majority of the remaining material and deposit it in containers for disposal. If there are no contraindications, use jets of water to eliminate product residues.
Materials: inert absorbent material (sand, vermiculite, diatomous earth, Kieselguhr, etc.)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Do not smoke while handling and use.
Store in a well ventilated place, keep far away from sources of heat, bright flames and sparks and other sources of ignition.
keep far away from sources of heat, bright flames and sparks and other sources of ignition.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
make sure that the workplace is well aired through effective local aspiration or bad air vent.
Protect hands with category I (ref. Directive 89/686/EEC and standard EN 374) work gloves, such as those in latex, PVC or equivalent. The following should be considered when choosing work glove material: degradation, breakage times and permeation. Work glove resistance to preparations should be checked before use, as it can be unpredictable. Gloves' limit depends on the duration of exposure.
Use of protective airtight goggles (ref. standard EN 166) recommended.
If the threshold value (if available) for one or more of the substances present in the preparation for daily exposure in the workplace or to a fraction established by the company's prevention and protection service is exceeded, wear a mask with an B or universal filter, the class (1, 2 or 3) of which must be chosen according to the limit concentration of use (ref. standard EN 141). The use of respiratory tract protection equipment, such as masks like that indicated above, is necessary to reduce worker exposure in the absence of technical measures. The protection provided by masks is in any case limited. If the substance in question is odourless or its olfactory threshold is higher than the relative exposure limit and in the event of an emergency, or when exposure levels are unknown or the concentration of oxygen in the workplace is less than 17% volume, wear self-contained, open-circuit compressed air breathing apparatus (ref. standard EN 137) or fresh air hose breathing apparatus for use with full face mask, half mask or mouthpiece (ref. standard EN 138).
Wear category I professional long-sleeved overalls and safety footwear (ref. Directive 89/686/CEE and standard EN 344).
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable in normal conditions of use and storage.
There are no particular risks of reaction with other substances in normal conditions of use.
No hazardous reactions are foreseeable in normal conditions of use and storage.
None in particular, however the usual precautions used for chemical products should be respected.
Information not available.
In the event of thermal decomposition or fire, vapours potentially dangerous to health may be released.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Reuse, when possible. Disposal must be performed through an authorised waste management firm, in compliance with national and local regulations.
Neat product residues should be considered special non-hazardous waste.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Healthcare controls: Information not available.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for INOX CLEAN?
The signal word is no signal word.
What is the physical form of INOX CLEAN?
INOX CLEAN is a liquid appearing as liquid with colourless color. It has odourless odor.
What is the solubility of INOX CLEAN?
soluble in water
What is INOX CLEAN used for?
Neutralizer for stainless steel
What is the melting point of INOX CLEAN?
The melting point is Not available. and the boiling point is Not available..