Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- CARBOGUARD 193 P - B
- Product Code
- 1193M000
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hardener for 2 components coatings - Industrial use.
Uses advised against
Please see Technical Data Sheet.
Manufacturers & Suppliers
Carboline Italia, S.p.a.
manufacturer
Via Margherita Vigano' De Vizzi . n 77, 20092 Cinisello Balsamo (MI), Italy
+39 02253751
Emergency Contacts
CHEMTREC
+1 703 5273887
PPC
+1 412 6816669
Centro Antiveleni di Roma (CAV Policlinico Umberto I - Roma)
+39 06 49978000
24h/24h
Emergenza ambientale
+39 335-601 32 88
Emergenza ambientale
+39 347-949 84 88
Emergenza ambientale
+39 348-246 90 99
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS05
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Fatty acids, C18-unsatd., dimers, oligomeric reaction products with triethylenetetramine EC: 500-290-3 | 103758-99-2 | 25 - 50% | Yes |
| hydrocarbons, c9, aromatics EC: 918-668-5 | --- | 10 - 25% | Yes |
| xylene EC: 215-535-7 | 1330-20-7 | 10 - 25% | Yes |
| 1-methoxypropan-2-ol EC: 203-539-1 | 107-98-2 | 10 - 25% | Yes |
| 2-methylpropan-1-ol EC: 201-148-0 | 78-83-1 | 2.5 - 10% | Yes |
| 2,4,6-tris(dimethylaminomethyl)phenol EC: 202-013-9 | 90-72-2 | 2.5 - 10% | Yes |
| ethylbenzene EC: 202-849-4 | 100-41-4 | 2.5 - 10% | Yes |
| Amines, polyethylenepoly-, triethylenetetramine fraction EC: 292-588-2 | 90640-67-8 | 1 - 2.5% | Yes |
The text for CLP Hazard Statements shown above (if any) is given in Section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Provide fresh air, rest and warmth. Call a physician immediately. Give oxygen or artificial respiration if needed. When risk of unconsciousness, place and transport the victim in secured recovery position.
Symptoms: Harmful by inhalation. Irritating to respiratory system. Vapours may cause drowsiness and dizziness.
Use a mild soap if available. Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes. If skin irritation persists, call a physician. Do not use solvent or thinners to clean skin.
Symptoms: Irritating to skin. May cause sensitization by skin contact.
Immediate medical attention is required. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Remove contact lenses.
Symptoms: Causes serious eye damage.
If vomiting occurs spontaneously: Keep head below hips to prevent aspiration of stomach vomit into lungs. Provide fresh air, rest and warmth. Do not induce vomiting. Get immediate medical attention. Never give anything by mouth to an unconscious person.
Immediate Medical Attention
Immediate medical treatment is necessary as untreated wounds from corrosion of the skin heal slowly and with difficulty. Get immediate medical attention. Immediate medical attention is required.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Carbon Dioxide, Dry Chemical, Foam
Alcohol, Alcohol based solutions, any other media not listed above. Do not use a solid water stream as it may scatter and spread fire.
Heating or fire conditions liberates toxic gas. Flash back possible over considerable distance. As the product contains combustible organic components, fire will produce dense black smoke containing hazardous products of combustion (see section 10). Vapours may form explosive mixtures with air. Solvent vapours are heavier than air and may spread along floors and ignite.
Keep containers and surroundings cool with water spray.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Do not allow material to contaminate ground water system. Prevent product from entering drains. Local authorities should be advised if significant spillages cannot be contained.
Contain spillage, soak up with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and transfer to a container for disposal according to local / national regulations. Clean with detergents. Avoid solvents.
Materials: non-combustible absorbent material (e.g. sand, earth, diatomaceous earth, vermiculite)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Prevent the creation of flammable or explosive concentrations of vapour in air and avoid vapour concentration higher than the occupational exposure limits. Wear personal protective equipment. Open drum carefully as content may be under pressure. Do not breathe vapours or spray mist. Persons with a history of skin sensitisation problems or asthma, allergies, chronic or recurrent respiratory disease should not be employed in any process in which this preparation is being used.
Store in original container. Keep locked up or in an area accessible only to qualified or authorised persons. Keep container closed. Store in a dry, well ventilated place away from sources of heat, ignition and direct sunlight. Store away from: oxidising materials, acids, and alkalis. Store in upright position only. Storage of flammable liquids.
Wash hands before breaks and at the end of workday. When using, do not eat, drink or smoke.
Take necessary action to avoid static electricity discharge. Prevent the creation of flammable or explosive concentrations of vapour in air. Electrical equipment should be protected. All metal parts of the equipment must be grounded.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Take note of the information given by the producer concerning permeability and break through times, and of special workplace conditions (mechanical strain, duration of contact). Be aware that in daily use the durability of a chemical resistant protective glove can be notably shorter than the break through time measured according to EN 374, due to the numerous outside influences (e.g. temperature). Use chemical resistant gloves and lotions and barrier creams to prevent drying of the skin. Protective gloves complying with EN 374: Nitrile rubber. Butyl rubber. Viton®. Recommended glove material for mixed product: Protective gloves complying with EN 374: Butyl rubber. Nitril rubber.
If splashes are likely to occur, wear: Face-shield, tightly fitting safety goggles (EN 166).
Use compressed air or fresh air breathing apparatus in closed compartments. Wear respiratory protection with combination filter (dust and gas filter, EN 14387:2004+A1:2008) during spraying operations: Gas filter type A2 (organic substances). Dust filter P3 (for fine dust).
Long sleeved clothing. Remove and wash contaminated clothing before re-use.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No reactivity hazards known under normal storage and use conditions.
No Information
Avoid heat, sparks, flames and other ignition sources.
Keep away from strong oxidising agents and strongly acid or alkaline materials.
In case of fire or hot work operations, hazardous decomposition products may be formed such as: Carbon dioxide (CO2), carbon monoxide (CO), oxides of nitrogen (NOx), aliphatic amines, aldehydes.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of waste material at an approved (hazardous) waste treatment/disposal facility in accordance with applicable local state, and federal regulations.
Dispose of waste material at an approved (hazardous) waste treatment/disposal facility in accordance with applicable local state, and federal regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Not applicable
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for CARBOGUARD 193 P - B?
The signal word is danger.
What is the physical form of CARBOGUARD 193 P - B?
CARBOGUARD 193 P - B is a liquid appearing as liquid . It has solvent odor.
What is CARBOGUARD 193 P - B used for?
Hardener for 2 components coatings - Industrial use.
What are the hazard statements for CARBOGUARD 193 P - B?
This substance has 9 hazard statements:
- H226: Flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H318: Causes serious eye damage.
- H332: Harmful if inhaled.
- H335: May cause respiratory irritation.
- H336: May cause drowsiness or dizziness.
- H373: May cause damage to organs through prolonged or repeated exposure.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of CARBOGUARD 193 P - B?
The melting point is Not determined and the boiling point is 106 - 200 °C.