Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- HYDROCARB 95T-OG
- Product Form
- fine powder
- Product Code
- 0540100
- Chemical Name
- Calciumcarbonate GCC coated fine powder
Regulatory Identifiers
- CAS Number
- N/A
- REACH No.
- Mixture
Identified Uses
Manufacture of paints, varnishes and similar coatings, printing ink and mastics, Manufacture of dyes and pigments, Manufacture of glues Mixing, Filling Fillers, Carrier, Colouring agents, pigments
Uses advised against
For industrial use only., Other industries not mentioned are excluded.
Manufacturers & Suppliers
Omya S.A. / N.V.
manufacturer
Chaussée de Wavre 1160 Bruxelles
+3226742311
Emergency Contacts
Emergency Contact
+41613192837
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
No dangerous ingredients according to Regulation (EC) No. 1907/2006
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Limestone EC: 215-279-6 | 1317-65-3 | 85 - 100% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion. If symptoms persist, call a physician.
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water.
Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing.
Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
Standard procedure for chemical fires.
Firefighter Protection
In the event of fire, wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special environmental precautions required.
Sweep up and shovel.
Materials: Keep in suitable, closed containers for disposal.
Related Products
Similar products with comparable safety profiles
Custom Hydrocarbon Mix
---
CAT HYDRAULIC OIL (HYDO) SAE 10W
---
HiTEC® 4995HR Fuel Additive
UFI: 1PJN-8MFW-F65F-XJ99
Castrol Hyspin AWH-M 100
---
HITECO 47001 Fuel Additive
UFI: FSTS-5049-G00Y-REC9
AW 68 HYDRAULIC OIL
---
Hydrocarbon Liquid
CAS: Not available.
DEVELON HYDRAULIC OIL PREMIUM VG 46
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
For personal protection see section 8. No special handling advice required.
Keep container tightly closed in a dry and well-ventilated place.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
For prolonged or repeated contact use protective gloves.
Safety glasses
When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Half mask with a particle filter P2 (EN 143).
Protective suit
No special environmental precautions required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if stored and applied as directed.
Stable under recommended storage conditions.
Reacts with acids. It forms carbon dioxide (CO2). This displaces the oxygen in the air in closed spaces. (danger of suffocation).
no data available
acids
> 600 °C
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Offer surplus and non-recyclable solutions to a licensed disposal company.
Offer surplus and non-recyclable solutions to a licensed disposal company.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for HYDROCARB 95T-OG?
The signal word is no signal word.
What is the physical form of HYDROCARB 95T-OG?
HYDROCARB 95T-OG is a solid at 20 °c (1.030 hpa) . It has characteristic odor.
What is HYDROCARB 95T-OG used for?
Manufacture of paints, varnishes and similar coatings, printing ink and mastics, Manufacture of dyes and pigments, Manufacture of glues Mixing, Filling Fillers, Carrier, Colouring agents, pigments
What is the melting point of HYDROCARB 95T-OG?
The melting point is > 800 °C and the boiling point is not applicable.