NextSDS Logo
HY

HYDROCARB 95T-OG

NO SIGNAL WORD solid at 20 °C (1.030 hPa) SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
HYDROCARB 95T-OG
Product Code
0540100

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Manufacture of paints, varnishes and similar coatings, printing ink and mastics, Manufacture of dyes and pigments, Manufacture of glues Mixing, Filling Fillers, Carrier, Colouring agents, pigments
Uses Advised Against
For industrial use only., Other industries not mentioned are excluded.

Overview

HYDROCARB 95T-OG commonly used manufacture of paints, varnishes and similar coatings, printing ink and mastics, manufacture of dyes and pigments, manufacture of glues mixing, filling fillers, carrier, colouring agents, pigments.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Omya S.A. / N.V.

national supplier

Chaussée de Wavre 1160 Bruxelles

BE

+3226742311

+3226742304

Omya International Ltd

global supplier

Group Regulatory Affairs, 4665 Oftringen, Switzerland

CH

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Omya International Ltd

+41613192837

CH

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

No dangerous ingredients according to Regulation (EC) No. 1907/2006

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Limestone
EC: 215-279-6
1317-65-3 85-100% Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Move to fresh air in case of accidental inhalation of dust or fumes from overheating or combustion.

Skin Contact

Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water.

Eye Contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing.

Ingestion/Swallowing

Clean mouth with water and drink afterwards plenty of water. Never give anything by mouth to an unconscious person.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solubility In Water
0,014 g/l at 20 °C at1.013 hPa 0,018 g/l at 75 °C
Ph
8,5 - 9,5
Odor Threshold
Not available
Colour
Not available
Relative Evaporation Rate
Not available
Odor
characteristic
Auto Ignition Temperature
Not available
Solubility
Not available
Partition Coefficient
POW: < 1 estimated
Vapor Pressure
Not available
Explosive Limits
Not available
Upper Explosive Limit
Not available
Cloud Point
Not available
Lower Explosive Limit
Not available
Relative Density
Not available
Bulk Density
Not available
Solubility In Fat
Not available
Kinematic Viscosity
Not available
Density
2,6 - 2,9 g/cm3
Critical Property
Metal Corrosion
Not available
Vapor Density
Not available
Flammability
The product is not flammable.
Freezing Point
Not available
Properties Status
Not available
Appearance
Not available
Crystallisation Point
Not available
Melting Point
> 800 °C
Critical Property
Decomposition Temperature
Not available
Flash Point
does not flash
Critical Property
Evaporation Rate
Not available
Dynamic Viscosity
Not available
Molecular Weight
Not available
Boiling Point
not applicable
Critical Property
Solidification Point
Not available
Colour Intensity
Not available
State Under Standard Conditions
Not available
Form
powder
Physical State Data
solid
Physical State
solid at 20 °C (1.030 hPa)
Critical Property
Voc Content
Not available
Softening Point
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

For prolonged or repeated contact use protective gloves.

Eye Protection

Safety glasses

Respiratory Protection

When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Half mask with a particle filter P2 (EN 143).

Skin/Body Protection

Protective suit

Environmental Exposure Controls

No special environmental precautions required.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for HYDROCARB 95T-OG?

The signal word for this substance is "no signal word".

What is the physical form of HYDROCARB 95T-OG?

HYDROCARB 95T-OG is a solid at 20 °c (1.030 hpa) . It has characteristic odor.

What is HYDROCARB 95T-OG used for?

Manufacture of paints, varnishes and similar coatings, printing ink and mastics, Manufacture of dyes and pigments, Manufacture of glues Mixing, Filling Fillers, Carrier, Colouring agents, pigments

What is the melting point of HYDROCARB 95T-OG?

The melting point is > 800 °C and the boiling point is not applicable.