NextSDS Logo
Safety Data Sheet EN

suspension polyvinylchloride homopolymer resin

CAS 9002-86-2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
suspension polyvinylchloride homopolymer resin

Regulatory Identifiers

CAS Number
9002-86-2 Check regulations →
REACH No.
This product is a polymer, which is exempted from registration according to (EC) regulation 1907/2006, article 2.

Identified Uses

Industrial: Manufacture of plastics products, including compounding and conversion

Manufacturers & Suppliers

M

Mexichem Resinas Vinílicas S.A. de C.V.

manufacturer

Autopista Altamira km. 4.5 Tamaulipas, Altamira Puerto Industrial México. C.P. 89608

+52 (55) 5366 4000

M

Mexichem Resinas Vinílicas, S.A. de C.V.

manufacturer

Planta Altamira II, Carretera Tampico Mante Km. 32, Col. Americana, Altamira, Tam. C.P. 89600 México.

Emergency Contacts

Emergency Contact

+52 833229 01 00 ext. 1459

works fire brigade

+49-2365-492232

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Polyvinylchloride

Chemical Name CAS Number Concentration Hazardous
Polyvinyl chloride (PVC) 9002-86-2 99% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of inhalation of decomposition products, affected person should be moved into fresh air and kept still.

Skin contact

After contact with skin, wash immediately with plenty of water and soap. Cool skin rapidly with cold water after contact with molten material. Do not peel solidified product off the skin.

Eye contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.

Ingestion

Rinse mouth immediately and drink plenty of water.

Immediate Medical Attention

Medical treatment necessary.

Medical Treatment

Medical treatment necessary.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray jet. Foam carbon dioxide. Extinguishing powder. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Specific hazards

In case of fire may be liberated: carbon monoxide, Hydrochloric gas

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Do not allow to enter into surface water or drains. Do not allow to enter into soil/ subsoil.

Cleanup methods

Take up mechanically, placing in appropriate containers for disposal.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Take precautionary measures against static discharges. Dust deposits / Avoid dust formation. Substance/product is self-extinguishing but can burn together with flammable materials.

Storage

Protect from moisture. Protect from heat and direct sunlight. Store at temperatures not exceeding 40°C/104°F.

Fire prevention

Take precautionary measures against static discharges. Substance/product is self-extinguishing but can burn together with flammable materials.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Respiratory

Particle filter device (DIN EN 143) Filter type: P1

Skin/Body

protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Vapor Pressure
---
Solidification Point
---
Evaporation Rate
---
Odor
odourless
Relative Evaporation Rate
---
Lower Explosive Limit
---
Ph
---
Softening Point
---
Properties Status
---
Metal Corrosion
---
Crystallisation Point
---
Solubility In Fat
---
Freezing Point
---
Decomposition Temperature
---
Odor Threshold
---
Upper Explosive Limit
---
Molecular Weight
---
Colour Intensity
---
Voc Content
---
Colour
white
Form
Powder
Melting Point
75 °C
Relative Density
---
Auto Ignition Temperature
>450 °C
Cloud Point
---
Physical State
Powder
Solubility In Water
The study does not need to be conducted because the substance is known to be insoluble in water.
Appearance
---
Flammability
---
Vapor Density
---
Boiling Point
---
Dynamic Viscosity
---
Physical State Data
solid
Flash Point
not applicable
State Under Standard Conditions
---
Solubility
---
Kinematic Viscosity
---
Explosive Limits
---
Density
1,4 g/cm³
Bulk Density
---
Partition Coefficient
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Reactivity

Thermal decomposition >100 °C

Decomposition

Hydrogen chloride (HCl), Carbon monoxide

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Send to a hazardous waste incinerator facility under observation of official regulations.

Disposal

Refer to manufacturer/supplier for information on recovery/recycling.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for suspension polyvinylchloride homopolymer resin?

The signal word is no signal word.

What is the physical form of suspension polyvinylchloride homopolymer resin?

suspension polyvinylchloride homopolymer resin is a powder with white color. It has odourless odor.

What is suspension polyvinylchloride homopolymer resin used for?

Industrial: Manufacture of plastics products, including compounding and conversion

What is the melting point of suspension polyvinylchloride homopolymer resin?

The melting point is 75 °C .