Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- RS Pro Ultrasonic Cleaning Liquid
- Product Code
- 764-3017, ZP
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 44R7-J06P-U004-KM5N
Identified Uses
Cleaning agent
Uses advised against
No specific uses advised against are identified
Manufacturers & Suppliers
RS Components Ltd
Birchington Road, Corby, Northants, NN17 9RS
+44 (0) 845 850 9900
RS Components Ltd
Glenview Industrial Estate, Herberton Road, Rialto, Dublin 12
+353 (0) 1 415 3100
Emergency Contacts
POISON INFORMATION CENTRE (Beaumont Hospital, Republic of Ireland only)
+353 (0)1 809 2166
08:00 - 22:00
Emergency Contact
+44 1235 239670
24hr
Emergency Contact
+44 (0) 1865 407333
24hr
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
This product does not contain candidate substances of very high concern at a concentration >=0.1% (Regulation (EC) No. 1907/2006 (REACH), Article 59)
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Hydrocarbons, C11-C13, isoalkanes, <2% aromatics EC: 920-901-0 | --- | 30 - 60% | Yes |
| hydrocarbons, C11-C12, isoalkanes, <2% aromatics EC: 918-167-1 | --- | 30 - 60% | Yes |
Full text of H- and EUH-phrases: see section 16
Notes
Acute Toxicity Estimate No information available
First Aid Measures
Emergency procedures for chemical exposure incidents
Aspiration into lungs can produce severe lung damage. If breathing has stopped, give artificial respiration. Get medical attention immediately. Remove to fresh air. Avoid direct contact with skin. Use barrier to give mouth-to-mouth resuscitation. If breathing is difficult, (trained personnel should) give oxygen. Get immediate medical attention. Delayed pulmonary edema may occur.
Symptoms: Difficulty in breathing. Coughing and/or wheezing. Dizziness.
Wash off immediately with soap and plenty of water while removing all contaminated clothes and shoes.
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area.
ASPIRATION HAZARD IF SWALLOWED - CAN ENTER LUNGS AND CAUSE DAMAGE. Do NOT induce vomiting. If vomiting occurs spontaneously, keep head below hips to prevent aspiration. Rinse mouth. Never give anything by mouth to an unconscious person. Get immediate medical attention.
Immediate Medical Attention
Immediate medical attention is required.
Medical Treatment
Note to doctors: Because of the danger of aspiration, emesis or gastric lavage should not be used unless the risk is justified by the presence of additional toxic substances.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry chemical. Carbon dioxide (CO2). Water spray. Alcohol resistant foam.
Do not scatter spilled material with high pressure water streams.
Risk of ignition. Keep product and empty container away from heat and sources of ignition. In the event of fire, cool tanks with water spray.
In the event of fire, cool tanks with water spray.
Firefighter Protection
Firefighters should wear self-contained breathing apparatus and full firefighting turnout gear. Use personal protection equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate personnel to safe areas. Keep people away from and upwind of spill/leak. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Do not touch or walk through spilled material. Stop leak if you can do it without risk.
Prevent further leakage or spillage if safe to do so. Prevent product from entering drains.
Dam up. Soak up with inert absorbent material. Pick up and transfer to properly labelled containers.
Materials: inert absorbent material
Related Products
Similar products with comparable safety profiles
Electronic Cleaning Solvent
---
Electronic Cleaning Solvent Plus
---
Mykal Ultrasonic Cleaner Plus
UFI: Y4SC-NAEK-F11J-PKJM
PressurePro Active Cleaner, alkaline RM 81
UFI: T440-F0W4-Y00T-K7F4
PressurePro Active Cleaner, alkaline RM 81
---
H Series Urine Analyzer Cleaning Liquid (Concentrated type)
---
CLEANING LIQUID, (ESL5) 100ML, CLEANING LIQUID, (ESL5) 500ML, ECO-UV, ESL5P-CL
---
ISE cleaning solution Sys Clean
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Use personal protection equipment. Avoid contact with skin and eyes. Avoid breathing vapours or mists. Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Use with local exhaust ventilation. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers. Use according to package label instructions.
Keep containers tightly closed in a dry, cool and well-ventilated place. Keep away from heat, sparks, flame and other sources of ignition (i.e., pilot lights, electric motors and static electricity). Keep in properly labelled containers. Do not store near combustible materials. Keep in an area equipped with sprinklers. Store in accordance with the particular national regulations. Store in accordance with local regulations. Store locked up. Keep out of the reach of children. Store away from other materials.
Do not eat, drink or smoke when using this product. Contaminated work clothing should not be allowed out of the workplace. Regular cleaning of equipment, work area and clothing is recommended. Wash hands before breaks and immediately after handling the product.
Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. Use grounding and bonding connection when transferring this material to prevent static discharge, fire or explosion. Use spark-proof tools and explosion-proof equipment. Keep in an area equipped with sprinklers.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ensure adequate ventilation, especially in confined areas.
Wear suitable gloves. Impervious gloves.
Tight sealing safety goggles.
No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required.
Wear suitable protective clothing. Long sleeved clothing. Chemical resistant apron. Antistatic boots.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
No information available.
None under normal processing.
Heat, flames and sparks.
None known based on information supplied.
None known based on information supplied.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Should not be released into the environment. Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Should not be released into the environment. Dispose of in accordance with local regulations. Dispose of waste in accordance with environmental legislation.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated
- Shipping Name
- Not regulated
- Transport Class
- Not regulated
- Packing Group
- Not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for RS Pro Ultrasonic Cleaning Liquid?
The signal word is danger.
What is the physical form of RS Pro Ultrasonic Cleaning Liquid?
RS Pro Ultrasonic Cleaning Liquid is a liquid appearing as liquid with colourless color. It has characteristic. odor.
What is the solubility of RS Pro Ultrasonic Cleaning Liquid?
No data available
What is RS Pro Ultrasonic Cleaning Liquid used for?
Cleaning agent
What are the hazard statements for RS Pro Ultrasonic Cleaning Liquid?
This substance has 1 hazard statement:
- H304: May be fatal if swallowed and enters airways
What is the melting point of RS Pro Ultrasonic Cleaning Liquid?
The melting point is No data available and the boiling point is No data available.