Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Unique Formula Identifier - for poison centres and emergency response
Uses Information
Overview
Interzone 1000 Red Part A is a liquid. color : red. substance commonly used professional use industrial use.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS02
GHS07
GHS09
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H226: Flammable liquid and vapor.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H411: Toxic to aquatic life with long lasting effects.
Precautionary Statements
- Wear protective gloves.
- Wear eye or face protection.
- Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
- Avoid release to the environment.
- Avoid breathing vapor.
- Wash hands thoroughly after handling.
- Collect spillage.
- Take off contaminated clothing and wash it before reuse.
- IF ON SKIN: Wash with plenty of water.
- If skin irritation or rash occurs: Get medical advice or attention.
- IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- If eye irritation persists: Get medical advice or attention.
- Store in a well-ventilated place.
- Keep cool.
- Dispose of contents and container in accordance with all local, regional, national and international regulations.
Manufacturers & Suppliers
Authorized suppliers, manufacturers, and distribution network information
International Färg AB
undefined
Holmedalen 3 Aspereds Industriomrade SE-424 22 Angered
SE
+46 (0) 31 928530
International Paint Ltd.
undefined
Stoneygate Lane Felling Gateshead Tyne and Wear NE10 0JY
GB
+44 (0)191 469 6111
+44 (0)191 438 3711
24/7 Emergency Response
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
National advisory body/Poison Center
+353 (0)1 809 2566
IE
Supplier
+46 (0) 31 928500
SE
24 hours
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| reaction product: bisphenol-A-(epichlorhydrin); epoxy resin EC: 216-823-5 | 1675-54-3 | 25-50% | Hazardous |
| Reaction mass of ethylbenzene and xylene EC: 905-588-0 | N/A | 10% | Hazardous |
| oxirane, mono[(C12-14-alkyloxy)methyl] derivs. EC: 271-846-8 | 68609-97-2 | 5% | Hazardous |
| cyclohexanone EC: 203-631-1 | 108-94-1 | 0.3% | Hazardous |
Additional Information
Occupational exposure limits, if available, are listed in Section 8.
Composition Notes
Type [1] Substance classified with a health or environmental hazard [2] Substance with a workplace exposure limit
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
Inhalation Exposure
Remove victim to fresh air and keep at rest in a position comfortable for breathing. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel. It may be dangerous to the person providing aid to give mouth-to-mouth resuscitation. Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms:
No specific data.
Skin Contact
Wash with plenty of soap and water. Remove contaminated clothing and shoes. Wash contaminated clothing thoroughly with water before removing it, or wear gloves. Continue to rinse for at least 10 minutes. Get medical attention. In the event of any complaints or symptoms, avoid further exposure. Wash clothing before reuse. Clean shoes thoroughly before reuse.
Symptoms:
Adverse symptoms may include the following: irritation, redness. Repeated or prolonged contact with the mixture may cause removal of natural fat from the skin, resulting in non-allergic contact dermatitis and absorption through the skin. This mixture may be a skin sensitizer and an irritant. Repeated skin contact may lead to irritation and to sensitization, possibly with cross-sensitization to other epoxies.
Eye Contact
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses if easy to do. Continue to rinse for at least 10 minutes. Get medical attention.
Symptoms:
Adverse symptoms may include the following: pain or irritation, watering, redness. If splashed in the eyes, the liquid may cause irritation and reversible damage.
Ingestion/Swallowing
Wash out mouth with water. Remove dentures if any. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs. Get medical attention if adverse health effects persist or are severe. Never give anything by mouth to an unconscious person. If unconscious, place in recovery position and get medical attention immediately. Maintain an open airway. Loosen tight clothing such as a collar, tie, belt or waistband.
Symptoms:
No specific data. Ingestion may cause nausea, diarrhea and vomiting.
Immediate Medical Attention Required
Get medical attention if adverse health effects persist or are severe. If unconscious, place in recovery position and get medical attention immediately. Treat symptomatically. Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
No specific treatment. Treat symptomatically.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Exposure Controls & Personal Protective Equipment
Occupational exposure limits, engineering controls, and required safety equipment
Engineering Controls
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Hand Protection
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. When prolonged or frequently repeated contact may occur, a glove with a protection class of 6 (breakthrough time >480 minutes according to EN374) is recommended. Recommended gloves: Viton ® or Nitrile, thickness ≥ 0.38 mm. When only brief contact is expected, a glove with protection class of 2 or higher (breakthrough time >30 minutes according to EN374) is recommended. Recommended gloves: Nitrile, thickness ≥ 0.12 mm. Gloves should be replaced regularly and if there is any sign of damage to the glove material. The performance or effectiveness of the glove may be reduced by physical/ chemical damage and poor maintenance. The user must check that the final choice of type of glove selected for handling this product is the most appropriate and takes into account the particular conditions of use, as included in the user's risk assessment.
Eye Protection
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: chemical splash goggles.
Respiratory Protection
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use.
Skin/Body Protection
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Refer to European Standard EN 1149 for further information on material and design requirements and test methods. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Environmental Exposure Controls
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
UN Number
UN1263
Proper Shipping Name
PAINT
Transport Hazard Class
3
Packing Group
III
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Interzone 1000 Red Part A?
The signal word for this substance is "warning".
What is the physical form of Interzone 1000 Red Part A?
Interzone 1000 Red Part A is a liquid. appearing as liquid. color : red. with red. color. It has solvent. odor.
What is the solubility of Interzone 1000 Red Part A?
cold water Not soluble [OESO (TG 105)]
What is Interzone 1000 Red Part A used for?
Professional use Industrial use
What are the hazard statements for Interzone 1000 Red Part A?
This substance has 5 hazard statements: H226: Flammable liquid and vapor. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H319: Causes serious eye irritation. H411: Toxic to aquatic life with long lasting effects.
What is the melting point of Interzone 1000 Red Part A?
The melting point is Not available. and the boiling point is 139°C (282.2°F).